• Title/Summary/Keyword: ozone consumption

Search Result 70, Processing Time 0.028 seconds

Simultaneous water and energy saving of wet cooling towers, modeling for a sample building

  • Ataei, Abtin;Choi, Jun-Ki;Hamidzadeh, Zeinab;Bagheri, Navid
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.173-181
    • /
    • 2015
  • This article outlines a case study of water and energy savings in a typical building through a modelling process and analysis of simultaneous water-energy saving measures. Wet cooling towers are one of the most important equipments in buildings with a considerable amount of water and energy consumption. A variety of methods are provided to reduce water and energy consumption in these facilities. In this paper, thorough the modeling of a typical building, water and energy consumption are measured. Then, After application of modern methods known to be effective in saving water and energy, including the ozone treatment for cooling towers and shade installation for windows, i.e. fins and overhangs, the amount of water and energy saving are compared with the base case using the Simergy model. The annual water consumption of the building, by more than 50% reduction, has been reached to 500 cubic meters from 1024 cubic meters. The annual electric energy consumption has been decreased from 405,178 kWh to 340,944 kWh, which is about 16%. After modeling, monthly peak of electrical energy consumption of 49,428 has dropped to 40,562 kWh. The reduction of 18% in the monthly peak can largely reduce the expenses of electricity consumption at peak.

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF

A Study on Odor-Savor and Microbiological Changes of Mineral Water Depending on the Storage Period (생수의 저장기간에 따른 이·취미 및 미생물학적 변화에 관한 연구)

  • Lee, Woo-Sik;Seo, Kwang-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.441-449
    • /
    • 2014
  • As people seek a healthy, wealthy, and quality life more than before, interests in mineral water are picking up and the consumption continues to increase accordingly. In an experiment to examine changes in the water quality after mineral water on the market was kept indoor and outdoor for four weeks, there seemed to be no problem in external appearance. Water kept in an outdoor storage contained more odor-savor than water kept in an indoor storage. Odor was not detected in 90% of the sample, and savor not in 80% of it. As for the mechanism of odor-savor generation, the elution of chemical substances from a container may be taken into consideration. In general, odor and savor have turned out to be in close correlation to each other. The average number of bacteria in the sample mineral water was $200{\pm}10CFU/mL$, and such factors as area of storage and ozone post-treatment did not cause significant effects on the reproduction of common microbes. Hence, it is thought that strict regulations on a production process and reduction of the period of circulation will contribute to customers consumption rates.

The Power Conversion System of a Sterilizer Processing for the Long Term Storage of Flours (밀가루 장기보관을 위한 살균처리 전력변환시스템)

  • 강욱중;정상화;고강훈;서기영;이현우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.27-34
    • /
    • 2001
  • There are several electricity applied sterilizers such as using high frequency, ozone, high voltage, and so on. Those sterilizers feature "because of no chemical process and no secondly environmental pollution". At the power conversion part, ZVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the propose device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduce. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with high voltage and field to and more economical and effective way, and to suggest mere improved sterilizer.

  • PDF

Development of Aging Equipment and Testing Method for UV Effected Degradation Characteristics of Silicone Rubber (자외선 열화에 의한 실리콘고무의 열화 특성 연구를 위한 열화장치 및 시험방법의 개발)

  • Lee, Jeong-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.93-96
    • /
    • 2007
  • In this paper, the testing equipment for evaluating aging characteristics of outdoor silicone rubber insulator resulting from the environmental aging effect with regards to sunlight(UV) was developed. Influence of sunlight effect aging is seriously increase due to destruction of ozone layer which is occurred by consumption of fossil fuel. For this purpose, silicone rubber was aged under the artificial sunlight by exposure of xenon lamp radiation in the accelerating aging chamber and various test and analysis were performed such as breakdown strength, contact angle. And FT-IR analysis has been followed.

  • PDF

Toluene Removal Using Surface Discharge Induced Plasma Chemical Process (연면방전 플라즈마를 이용한 톨루엔 처리에 관한 연구)

  • 부문자;봉춘근;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.297-305
    • /
    • 1997
  • The experimental study by use of SPCP was fulfilled to remove toluene emitted from various industrial processes. First of all, discharge characteristic was experimented as the change of applied voltage and frequency. Then toluene removal characteristic was tested with the analysis of by-products. As a result, optimum electrical discharge condition was from 20.0 kHz to 25.0 kHz of frequency and from 3.5 kV to 4.0 kV of voltage range. The variation of applied voltage had a more important effect on the removal characteristic of toluene than the frequency variation. The toluene removal efficiency was proportioned to ozone concentration and retention time on discharge plate. It was dropped as increase of toluene concentration, but total treated volume of tolene per power consumption was high. The decomposed toluene was transformed to $CO, CO_2$ and particulates, and the rate of transformation to particulates was higher than CO and $CO_2$ at high toluene concentration. Particulates were increased from 0.017 $\mum$ to 0.3 $\mum$ range of size distribution.

  • PDF

Evaluation of VOCs in Kumi industrial Complex (공단지역에서의 휘발성유기화합물의 농도 평가)

  • 배상호;최우건;박덕신;정우성;김태오
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.943-947
    • /
    • 2002
  • Volatile Organic Compounds(VOCs) contribute to the formation of ozone and PAN which are injurious to health through complex photochemical reactions. Growing consumption of fossil fuels results in significant emission of VOCs and other air pollutants into the atmosphere. This study was carried out to evaluate of Volatile Organic Compounds(VOCs) concentrations in Kumi industrial complex. Ambient air sampling was determined at five sites from August to September in 2002. The Volatile Organic Compounds samples were collected using the silicocan canisters, and were determined by GC/MS which connected preconcentrator system. The Kumi industrial complex of VOCs concentrations were generally similar with Yeochun's but some of VOCs concentrations of Kumi were higher than Yeochun industrial complex's. Also the industrial area was higher than downtown and residential district.

  • PDF

Evaluation of VOCs in Subway (지하철역사에서의 휘발성 유기화합물 농도 평가)

  • 최우건;배상호;박덕신;정우성;김태오
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.572-576
    • /
    • 2002
  • Volatile Organic Compounds(VOCs) contribute to the formation of ozone and PAN which are injurious to health through complex photochemical reactions. Growing consumption of fossil fuels results in significant emission of VOCs and other air pollutants into the atmosphere. In this study, Ambient an grab samples of VOCs were collected at the platform and the concourse of six stations in the subway from February 21th to 28th. Among the total contents, Toluene (118.74 ppm) showed the highest concentration in the Indukwon station platform while other contents were measured low concentrations. Also, the platform concentrations were higher than the concourse concentrations through the whole contents.

  • PDF

Charge Transportation Characteristics of Alumina Discharge Chamber for Ozone Generation (오존발생을 위한 알루미나 방전관의 전하수송 특성)

  • Kim, Byung-Sub;Lee, Sung-Wook;Park, Gang-Il;Lee, Soo-Ho;Kwak, Dong-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.529-532
    • /
    • 2003
  • In this paper, the discharge characteristics of silent discharge chamber with 2mm and 3mm gap spacings were investigated. Dielectric of $Al_2O_3$ was embedded in the cylindrical type of discharge chamber. It was known that V-I and P-V characteristics depend strongly on the charge transportation characteristics, and in the low frequency silent discharge mode of operation, discharge voltage was always sustained to Vd, irrespective of applied voltage.

  • PDF