• Title/Summary/Keyword: ozone concentration

Search Result 758, Processing Time 0.021 seconds

A Study of Ozone Passive Sampler(I)-Sensitivity on Filter Substrate (오존 간이측정기에 대한 연구(I)-필터의 민감도)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.383-391
    • /
    • 2002
  • Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.

Ozone Generation of a Small Sawtooth-to-Cylinder Electrode Applied a Pulse Voltage (원톱날 -원통 전극간의 오존 발생특성)

  • 문재덕;김정호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.651-654
    • /
    • 1987
  • There are a number of small scale application fields of ozone, such as food conservation and/or storage in refrigerators, containers and storage rooms, deodorization in the production and living areas, protection against biohazards, bleaching of fabrics, etc. For these applications, miniaturization, ozone controllability and costdown of the ozonizer are the most essential points, whereas power efficiency is the most imporant factor in the case of a large scale ozonizer used in various industrial applications. It has been developed a novel sawtooth-to-cylinder type micro-ozonizer meeting above the three points by using a negative pulse corona discharge. As a result of the observations of pulse coronas affecting ozone generation, it is found that the maximum ozone concentration is generated at the pulse streamer coronas in both positive and negative case. The ozone concentration (20ppm/2l/min) generated by the negative pulse corona is about 2 times higher than that of the positive pulse corona, and could be controllable linearly by adjusting the dc input voltage of the [supply-inth ] cinventional small scale ozonizers. As a result, the present ozonizer is also very good to be used as a micro-ozonizer.

  • PDF

A Study on the Characteristics of Rural and Urban Surface Ozone Conentrations (청정지역과 도시지역의 오존농도 특성 연구)

  • 서명석;박경윤;이호근;장광미;강창희;허철구;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.253-262
    • /
    • 1995
  • A study has been performed on the characteristics of rural and urban surface ozone concentration for the period of March 1992 to February 1993. The monitoring station of rural ozone is located at Kosan, Cheju and other urban monitoring stations are located at Seoul, Pusan and Kwangju. Rural's and urban's ozone data exhibit a distinct features in many ways. First, annual mean of rural ozone concentration os very high(42 ppbv) but urban's are very low(10 .sim.15 ppbv). Second, rural ozone data shows a seasonal variation with it's maximum in spring, and minimum in summer, but urban's show a seasonal variation with it's maximum in spring, and minimum in winter. Third, diurnal variation of rural data is very small but that of urban's are very large. Fourth, urban's data are extremely low(< 3 ppbv) and have no seasonal variations.

  • PDF

Formation behaviour of Bromate in Processes of Advanced Water Treatment System using Nakdong river water (고도정수처리 공정에서 브로메이트의 거동 평가)

  • Kim, Young-Jin;Hyun, Kil-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.605-610
    • /
    • 2011
  • The objectives of this study are to investigate a bromate behaviour in the processes of advanced water treatment system (AWTS: preozonation, coagulator-settler, rapid sand filter, postozonation, biological activated carbon (BAC) beds) and to investigate the effects of ozonation, pH and ammonia nitrogen on bromate (${BrO^-}_3$) formation. As a result, $BrO_3$ was not detected in the processes of the AWTS without ozonation, while it was detected in a preozonated and postozonated water. For $BrO_3$ formation during June to November, the $BrO_3$ concentration of <9.4${\mu}g/L$ was observed in postozonated water, while it was reduced to about 46% by BAC beds. When applied ozone dosage and ozone contact time for influent with $Br^-$ of <0.3mg/L were 0.5-2.0mg/L.min and 10 min., $BrO_3$ concentration increased with increasing ozone dosage. Longer contact time and lower ozone level also was needed to inhibit the formation of $BrO_3$. At ozone dosage of 1.4 mg/L.min, the formation rate of $BrO_3$ increased with increase of pH value. When $NH_4-N$ concentration increased from 0.1mg/L to 0.4mg/L, $BrO_3$ concentration decreased to about 38%. These results revealed that $BrO_3$ concentration increased with increasing Br level, ozone dosage, and pH value, while it decreased with increase of $NH_4-N$ concentration.

Decomposition of Humic Acid and Reduction of THM Formation Potential by Ozone and Combined Ozone/Ultraviolet Oxidation (오존 및 오존/UV 산화법을 이용한 휴믹산의 분해와 THM 발생능의 감소)

  • Park, Ju-Seok;Park, Tae-Jin;Kwon, Bong-Kee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.55-63
    • /
    • 1996
  • This research was based on comparing ozonation with combined ozone/ultraviolet oxidation through the methods of reducing THM produced during water treatment. The results were as follows ; 1. The decline of THM concentration was appeared according as ozone dosage increases with ozonation and combined ozone/ultraviolet oxidation. The more effective method was the treatment of irradiating UV then ozonation. In the beginning of reaction the decline rate of THM formation potential was low, I thought it was because that the reaction of ozone and humic acid needed times to be steady state, or that THM formation potential existed according to humic acid. 2. The effect of combined ozone/ultraviolet oxidation when ozone dosage was 4.2mg/L min was almost the same that of ozonation when ozone dosage was 8.6mg/L min. 3. In experiment of TOC decline through ozonation and combined ozone/ultraviolet oxidation, TOC concentration was also dropped according to increasing ozone dosage and the more effective results were showed in treatment of irradiating UV than ozonation. But the similar TOC remove rates were showed in experiment of changing with ozone dosage during combined ozone/ultraviolet oxidation TOC remove rates were low in proportion to the remove rates of THM formation potential, it was considered that humic acid was made low molecule itself though ozonation and ozone/ultraviolet oxidation. Moreover, the high degree of remove efficiency will be get though the treatment of activated carbon of GAC treatment after combined ozone/ultravilet oxidation.

  • PDF

A Study on the Ozonation Characteristics of the Phenol Contaminated Wastewater by Increasing Phenol Concentration in the Continuous PCR and BCR (연속식 PCR과 BCR에서 페놀 농도 증가에 따른 오존 처리 특성에 관한 연구)

  • Kim, Yong-Dai;Ahn, Jae-Dong;Lee, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.12-19
    • /
    • 1995
  • The objectives of this research prograln were to study the ozonation characteristics of phenol contaminated wastewater in the continuous packed column reactor (PCR) and the bubble column reactor (BCR) using ozone that has a strong oxidizing potential, and to provide the fundamentals of ozonizing the phenol contaminated wastewater. Among various influencing factors on phenol decomposition through the oxidation by ozone, phenol/ozone mde ratio was chosen as reaction parameters. Concerning the phenol/ozone mde ratio, as the influent phenol concentration increased from 30 mg/l to 150 mg/l, the phenol removal efficiency decreased from 99% for 30 mg/l to 83.7% for 150 mg/l, in PCR. PCR also showed higher treatment efficiency than BCR by 1% for 30 mg/l and 2.2% for 150 mg/l, respectively. The ozone utilization efficiency of PCR for the phenol concentration 30 mg/l was higher than that of BCR while the efficiency of both reactors was 99.9% for the phenol concentration of 150 mg/l.

  • PDF

Characteristics of manganese removal by ozonation: Effect of existing co-ion and optimum dosage (오존을 이용한 용존성 망간 제거 특성: 공존이온의 영향 및 최적주입량)

  • Kwak, Yeonwoo;Lee, Seulki;Lee, Yongsoo;Hong, Seongho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.145-152
    • /
    • 2018
  • This study is focused on manganese (Mn(II)) removal by ozonation in surface water. Instant ozone demand for the water was 0.5 mg/L in the study. When 0.5 mg/L of Mn(II) is existed in water, the optimum ozone concentration was 1.25 mg/L with reaction time 10 minutes to meet the drinking water regulation. The ozone concentration to meet the drinking water regulation was much higher than the stoichiometric concentration. The reaction of soluble manganese removal was so fast that the reaction time does not affect the removal dramatically. When Mn(II) is existed with Fe, the removal of Mn(II) was not affected by Fe ion. However As(V) is existed as co-ion the removal of Mn(II) was decreased by 10%. Adding ozone to surface water has limited effect to remove dissolved organic matter. When ozone is used as oxidant to remove Mn(II) in the water, the existing co-ion should be evaluated to determine optimum concentration.

Development of the DIW-$O_3$ Cleaning Technology Substituted for the Semiconductor Photoresist Strip Process using the SPM (SPM을 이용한 반도체 포토레지스트 제거 공정 대체를 위한 DIW-$O_3$ 방식 세정기술 개발)

  • Son, Yeong-Su;Ham, Sang-Yong
    • 연구논문집
    • /
    • s.33
    • /
    • pp.99-109
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DIW-$O_3$) in semiconductor wet cleaning process and photoresist stripping process to replace the conventional sulfuric acid and hydro peroxide mixture(SPM) method has been studied. In this paper, we propose the water-electrode type ozone generator which has the characteristics of the high concentration and purity to produce the high concentration DIW-$O_3$ for the photoresist strip process in the semiconductor fabrication. The proposed ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. Through this study, we obtained the results of the 10.3 wt% of ozone gas concentration at the oxygen gas of 0.5 [liter/min.] and the DIW-$O_3$ concentration of 79.5 ppm.. Through the photoresist stripping test using the produced DIW-$O_3$, we confirmed that the photoresist coated on the silicon wafer was removed effectively in the 12 minutes.

  • PDF

A Study on the Decomposition Rate of Phenol in the Batch Type Ozonation (회분식 오존 공정에서 페놀의 분해 속도에 관한 연구)

  • 안재동;강동수
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.127-132
    • /
    • 1997
  • The characteristics of the ozone treatments of phenol were studied in a laboratory scale wastewater treatment system. The ozone treatment of wastewater was carried out in a batch-type reactor. The initial pH of wastewater(7-10), volumetric flow rate(1-2l/min) and ozone concentration(20~30 mg/l) of aerating gas were considereal as experimental variables in the ozone treatment. Phenol was decomposed easily by the ozone in a batch treatment, where the rate determining step was the COD removal that is decomposition of intermediates formed by the ozonation of phenol. Phenol decomposition and COD removal could be expressed by the first order reaction for the phenol concentration and COD, respectively. Rate constants of phenol decomposition and COD removal increased with the initial pH, volumetric flow rate and ozone concentration of aeration gas. Under the present experimental condition, their relationships could be given by for the phenol decomposition $k'=4.46\times 10^{-9}[pH]_o ^{3.94}[O_3]^{1.42}Q_{O3}^{1.57}$ for the COD removal $k=2.46\times 10^{-10}[pH]_o ^{5.19}[O_3]^{1.15}Q_{O3}^{1.19}$

  • PDF

High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas (입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성)

  • 박승록;이대희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2002
  • There are many effective parameters to high concentration ozone generation. These parameters became very important elements should be considered before designing ozone generator. After designing, there are many peripheral parameters to greatly affect to high concentration ozone generation also. In this study, of many effective peripheral parameters on high concentration ozone generation, the effects of flow rate of inlet oxygen gas and some kinds of additional gases on ozone concentration were investigated As a result, when inlet oxygen gas was introduced at the range of 0.75[LPM]~2.00[LPM] the highest ozone concentration of 71145[ppm] was obtained at 1.25[LPM]. When the additional nitrogen gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest ozone concentration of 73135[ppm] was obtained at 0.8[vol%] of nitrogen gas. This showed 3[%] increasing compared to the case of pure oxygen gas inlet. When the additional argon gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest concentration of 67288[ppm]was obtained at 0.8[vol%]of argon gas. This is decreased value compared to that of introducing the pure oxygen.