Abstract
Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.