• Title/Summary/Keyword: ozone concentration

Search Result 758, Processing Time 0.025 seconds

Sensitivity of Ozone to NOx and VOCs in a Street Canyon (도로 협곡에서 NOx와 VOCs에 대한 오존의 민감도)

  • Lee, Kwang-Yeon;Kwak, Kyung-Hwan;Park, Seung-Bu;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.307-316
    • /
    • 2013
  • The sensitivity of ozone to $NO_x$ and volatile organic compounds (VOCs) emission rates under different ventilation rates and $NO_2-to-NO_x$ emission ratios in a street canyon is investigated using a chemistry box model. The carbon bond mechanism IV (CBM-IV) with 36 gaseous species and 93 chemical reactions is incorporated. $NO_x$ and VOCs emission rates considered range from 0.01 to $0.30ppb\;s^{-1}$ with intervals of $0.01ppb\;s^{-1}$. Three different ventilation rates and three different $NO_2-to-NO_x$ emission ratios are considered. The simulation results show that the ozone concentration decreases with increasing $NO_x$ emission rate but increases with increasing VOCs emission rate. When the emission ratio of VOCs to $NO_x$ is smaller than about 4, the ozone concentration is lower in the street canyon than in the background. On average, the magnitude of the sensitivity of ozone to $NO_x$ emission rate is significantly larger than that to VOCs emission rate. As the $NO_x$ emission rate increases, the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates decreases. Because the ozone concentration is lower in the street canyon than in the background, the increased ventilation rate enhances ozone inflow from the background. Therefore, the increase in ventilation rate results in the increase in ozone concentration and the decrease in the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates when the emission ratio of VOCs to $NO_x$ is smaller than about 4. On the other hand, the increase in $NO_2-to-NO_x$ emission ratio results in the increase in ozone concentration because the chemical ozone production due to the $NO_2$ photolysis is enhanced. In the present experimental setup, the contribution of the change in $NO_2-to-NO_x$ emission ratio to the change in the sensitivity of ozone to $NO_x$ emission rate is larger than that of the change in ventilation rate.

A Study on the Trial Manufacture and Characteristics of Lamp Type Ozonizer (Lamp 형 오존발생기의 시작 및 특성에 관한 연구)

  • Kim, Sang-Ku;Song, Hyun-Jig;Kang, Cheon-Su;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.6
    • /
    • pp.62-72
    • /
    • 1996
  • In this paper, ozonizer using U-type lamp(Olamp) has been designed and manufactured, which can perform a role of lighting source and ozonizer by using photo and chemical methods. The discharge, spectrum, illuminance, ozone concentration, ozone generation, ozone yield and sterilization characteristics of Olamp have been studied. The important conclusions obtained from this paper can be summa'||'&'||'not;rized as follows. As a result of spectrum characteristics for Olamp, ultraviolet ray of a short wave'||'&'||'not;lengths and a visible ray are radiated. The illuminance of Olamp was found to be useful for "color distinctive and intermittent works in the dark working spaces" in accordance with KS A 3011. The ozone concentration of gaseous phase is inversely proportional to quality of supplied gas. Also, ozone conce tration and generation of gaseous phase are rised more commercial oxygen gas than those trial air gas for constant quality of supplied gas. Ozone generation and ozone yield of gaseous phase are proportion'||'&'||'not;al to ozone concentration of gaseous phase. The characteristics of liquid ozone concentration at distilled water are proportional to circulating velocity of fermentation chamber and ozone concentration of gas'||'&'||'not;eous phase. As a result, the sterilization characteristics of Escherichia coli have been obtained more than 97[ % J.

  • PDF

A Case Study of Characterization of AOC Formation

  • Kim, Ji-Hoon;Hwang, Hyeon-Uk;Kim, Young-Ju
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.261-267
    • /
    • 2010
  • The variation of assimilable organic carbon(AOC) concentration at each condition of ozonation was investigated using a model water and drinking water resource. AOC concentration of model raw water and drinking water resource tended to increase at low ozone dose. The maximum AOC concentration was detected when the residual ozone begin to be measured. Also, the AOC concentration increase at pH 8 compared to both pH 6 and 7 while that for pH 9 decreased rapidly. The removal characteristics of trihalomethane formation potential(THMFP) by ozonation was also investigated. Unlike the trend of AOC, the THMFP concentration never increased by ozonation but decreased even at low ozone dosage. From these results, the ozone dosage would be effective to simultaneously decrease both AOC and THMFP.

The Analysis of Atmospheric Flow Field and Air Quality According to the High Level Ozone Case on Gwangyang Bay (광양만 권역에서의 고농도 오존 사례에 대한 기상 및 대기질 분석)

  • Choi, Hyun-Jung;Lee, Hwa-Woon;Leem, Heon-Ho;Song, Jae-Hwal
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.743-753
    • /
    • 2008
  • Gwangyang Bay is often severely confronted by photochemical pollutants due to its location and dense emissions. It is located in a basin on the south coast of the Korean peninsula and is crossed by a remarkable cluster of hills and mountains of a small horizontal scale that forms a channel. Clearly, the air flow field has a great influence on the dispersion of air pollutants. The characteristics of the wind flow patterns have an important effect on the dispersion of pollutants emitted. In these situations, the distribution of the ozone concentration is extremely complicated because of the superposition of circulations of the air flow fields, especially in complex coastal region. In this study, we examined the distribution of the high level ozone on Gwangyang Bay particularly during the episode day (for 5 years). Among these days, A high level ozone was induced by the development of a sea/land breeze local circulation system, as well as by an anabatic/catabatic flow from the mountains and valley with weakening of the synoptic wind. High level ozone distribution pattern(6 types) on Gwangyang bay is analyzed and the comparison of each pattern reveals substantial localized differences in intensity and distribution of ozone concentration from the site coherence and UPA analysis of ozone concentration. The observed VOC concentration had much difference in concentrations and daily variations between Jungdong and Samil.

Relationship Between Ozone Concentrations and Affecting factors in Seosan City of Korea (충남 서산지역 대기 중의 오존농도와 그 영향인자와의 관련성)

  • Kim, Jun-Kyeom;Jeong, Yong-Jun;Cho, Young-Chae
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.78-88
    • /
    • 2003
  • This study was conducted to investigate the relation between ozone concentration and the affecting factors in Seosan City of Korea from Jan. 2002 to Dec. 2002. We analyzed the air pollutants such as NO$_2$, PM$_{10} $,SO$_2$, CO and the meteorological factors including solar radiation, air temperature, wind speed and relative humidity. The analytical data were taken statistics by SPSS method. The results were as follows: The seasonal average concentration of ozone were detected 35.0 ppb in Spring, 25.4 ppb in Summer, 23.5 ppb in Autumn and 21.4 ppb in Winter. So the difference of concentrations showed significantly in statistics. The hourly ozone concentration in a day was increased at 7-9 AM, peaked at 3-4 PM. The correlation coefficients was negative to ozone concentration and NO$_2$, SO$_2$, CO, relative humidity, but positive to solar radiation, air temperature, wind speed. With stepwise multiple regression analysis on the 8 factors such as NO$ _2$, PMSO$_{10}$,SO$_2$, CO, solar radiation, air temperature, wind speed and relative humidity, the seasonal primary factors were air temperature in spring, relative humidity in summer and solar radiation in autumn and winter. The above results suggest that ozone is the secondary pollutant by photochemical reaction as the concentration of ozone was increased with the raise of solar radiation.

A Study of Ozone Occurrence Amount by Copy Machine Use in School and Around of School (학교 내.외 복사기 사용에 따른 오존 발생량 연구)

  • Noh Sun-Jin;Jung Kyung-Sick;Seo Seung-Pyo;Son Bu-Soon;Lee Jong-Wha;Lee Che-Won
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.58-65
    • /
    • 2006
  • This study is measured in at ozone concentrated places in school and outside of school where places that use copy machine and the others do not use one. Library copy room, Search room, Y-Copy, J-copy, R-shop are the places using copy machines and Search room, K-apt, J-billiard hall are the opposite. The measurement was held three times a day-the morning, the afternoon and the evening-once for each at indoor and outdoor. 8 places were lower than domestic ozone concentration standard(0.06ppm). The indoor ozone concentration average was the highest in Search room of school and was the lowest in Library restroom. The outdoor ozone concentration average was the highest in J-billiard hall.

A Study on the Removal of Low-Concentration Ozone by means of Activated Carbon (활성탄을 이용한 저농도 오존(OZONE)제거에 관한 연구)

  • 양원호;최경호;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.57-63
    • /
    • 1997
  • This study was carried out to find the adverse health effects of ozone by papers, the potential indoor sources of ozone by papers, and then the removal mechanism of ozone by experiments. The exposure of individuals to excessive levels of ozone both in the industrial and ambient environment is a continuing public health concern. Ozone indoors may play a role in generating secondary pollutants that may have adverse health effects. The removal efficiency of ozone was studied by (1) the effect of concentration on breakthrough time, (2) the effect of flow rate on breakthrough time, (3) the effect of adsorbent's weight on breakthrough time, (4) the effect of temperature on breakthrough time, (5) the application of Langmuir's isotherm equation in using activated carbon. The followings are the conclusions that were derived from this study. 1. In the effect of concentration on breakthrough time, the adsorption capacity of activated carbon was inversely proportional to ozone concentratuion (0.1, 0.2, 0.3 ppm). 2. In the effect of flow rate on breakthrough time, the service life of activated carbon was inversely proportional to flow rate (2, 8, 14l/min). 3. The difference in removal efficiency of ozone between weights(100 mg and 150 mg) was seen. And when weight of activated carbon was 100 mg and 150 mg, pressure loss was 4-5mmHg and 6-7mmHg, respectively. It is required to study relations among flow rate and adsorbent's weight and ventilation quantity, too. 4. Generally, Langmuir's equation, one of the oldest and most used frequently isotherm equation, applies to chemisorption. In case of ozone, when the weight of activated carbon was 70 mg and temperature 40, slope(1/a) was $6.25\times 10^{-1}$ and intercept(1/ab) was $1.9\times 10^{-4}$ (average r=0.94).

  • PDF

Discharge Area Characteristics of Ozonizer with $Al_2O_3$ Dielectric ($Al_2O_3$ 세라믹 유전체 오존발생기의 방전면적 특성)

  • Park, Hyun-Mi;Song, Hyun-Jig;Lee, Sang-Gun;Lim, Chang-Ho;Yoon, Bung-Han;Kim, Jong-Hyun;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2214-2216
    • /
    • 2005
  • This paper is researched discharge and ozone generation characteristics of ozonizer using $Al_2O_3$ Ceramic dielectric. The discharge characteristics with variation of the discharge electrode area is studied. The characteristics of ozone concentration. ozone generation and ozone yield were measured to discharge power, discharge electrode area and supplied gas flux for oxygen and air. The solubility of ozone for water concentrations and ozone generations proportional to discharge power and discharge electrode area. Ozone yield has slowly increase with Increasing discharge power at high flow-rate. As the result, the maximum values of ozone characteristics ozone generation and ozone yield, can be obtained 5817[ppm] and 36[g/kWh]. We make enough the ozone concentration as the air in the home. An electric discharge electrode area is apt to shrink gradually into a miniaturization trend of the ozonizer but the enlargement of the occurrence flight of the electric discharge area gives the characteristic enhance the aid in the identity condition through the structure improvement.

  • PDF

Meteorological Characteristics of High-Ozone Episode Days in Daegu, Korea (대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성)

  • Son, Im-Young;Kim, Hee-Jong;Yoon, Ill-Hee
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.424-435
    • /
    • 2002
  • This study analyzes the surface ozone and meteorological data in Daegu for a period from 1997 to 1999. It also investigates the meteorological characteristics of high ozone episodes. For this study the high ozone episode has been defined as a daily maximum ozone concentration higher than 100ppb in at least one station among six air quality monitoring stations in Daegu, Korea. The frequency of episodes is 13 days. The frequency is the highest in May and September. The average value of daily maximum ozone concentration is 81.6ppb, and 8-hour average ozone concentration is 58.6ppb for the high episodes. This shows that ozone pollution is continuous and wide-ranging in Daegu. The daily maximum ozone concentration is positively correlated to solar radiation and daily maximum temperature, but negatively correlated to relative humidity, wind speed and cloud amount. The maximal correlation coefficient to solar radiation is 0.45. The differences between high ozone episode day's daily mean meteorological value and monthly mean value are +1.58hPa for sea level pressure, +3.45${\circ}$C for maximum temperature, -5.69% for relative humidity, -0.46ms$^{-1}$ for wind speed, -1.79 for cloud amount, and +3.97MJm$^{-2}$ for solar radiation, respectively. This shows that strong solar radiation, low wind speed and no precipitation between 0700${\sim}$1100LST are favorite conditions for high ozone episodes. It is related to the morning stagnant condition.

Performance Characteristics of a Pin-to-Cylinder Superposed Discharge Type Ozonizer (SDO)

  • Md. Fayzur Rahman;Lee, Kwang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.113-119
    • /
    • 2001
  • This paper presents a model for a pin-to-cylinder discharge type ozonizer, which utilizes the superposition of surface discharge and corona discharge operation. By changing the gas flow rate, the discharge power and the number of SDO units, the characteristics of ozone concentration ( $O_{3con}$), ozone generation ( $O_{3g}$) and ozone yield ( $O_{3Y}$) were investigated. Using one SDO unit the maximum values of $O_{3con}$, $O_{3g}$ and $O_{3Y}$ were found as 8100[ppm], 1623[mg/h] and 213[g/kWh] respectively. With two SDO units the corresponding values were found as 12800[ppm], 2893[mg/h] and 248[g/kWh] respectively. Hence using two SDO units the efficiency was improved by 16[%].y 16[%].

  • PDF