• Title/Summary/Keyword: ozone$PM_{10}$

Search Result 119, Processing Time 0.024 seconds

Comparison between Atmospheric Chemistry Model and Observations Utilizing the RAQMS-CMAQ Linkage, Part II : Impact on PM2.5 Mass Concentrations Simulated

  • Lee, DaeGyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.108-114
    • /
    • 2014
  • In the companion paper (Lee et al., 2012), it was showed that CMAQ simulation using a lateral boundary conditions (LBCs) derived from RAQMS-CMAQ linkage, compared to the CMAQ results with the default CMAQ LBCs, improved ozone simulations in the conterminous US domain. In the present paper, the study is extended to investigate the influence of LBCs on PM2.5 simulation. MM5-SMOKE-CMAQ modeling system was used for meteorological field generation, emissions preparation and air quality simulations, respectively. Realtime Air Quality Modeling System (RAQMS) model assimilated with satellite observations were used to generate the CMAQ-ready LBCs. CMAQ PM2.5 simulations with RAQMS LBCs and predefined LBCs were compared with U.S. EPA Air Quality System (AQS) measurements. Mean PM2.5 lateral boundary conditions taken from RAQMS outputs showed strong variations both in the horizontal grid and vertical layers in the northern and western boundaries and affected the results of CMAQ PM2.5 predictions. CMAQ with RAQMS LBCs could improve CMAQ PM2.5 predictions resulting in the improvement of index of agreement from 0.38 to 0.63.

A Study of Ozonation of Dimethyl Phthalate (Dimethyl Phthalate의 오존산화 반응에 관한 연구)

  • Lee, Cheal-Gyu;Song, Jun-O
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.703-709
    • /
    • 2013
  • Ozonation was performed under various experimental conditions that $Al_2O_3$ catalysts dosage and temperature for removal of DMP in laboratory scale batch reactor. Flow rate of ozone $1.0Lmin^{-1}$ and ozone concentration of $300{\pm}10mgL^{-1}$ were maintained constantly, and the pH, $COD_{Cr}$ and TOC was measured in 10 min intervals during the 60 min at oxidation processes. As a result, the presence of the $Al_2O_3$ than only ozonation increased the removal efficiency of both $COD_{Cr}$ and TOC in solution. The pseudo first-order rate constants for the elimination of $COD_{Cr}$ and TOC were $3.65{\times}10^{-4}sec^{-1}$, $2.52{\times}10^{-4}sec^{-1}$, and activation energy was $0.75kcal{\cdot}mol^{-1}$ and $0.70kcal{\cdot}mol^{-1}$ at $20^{\circ}C$, respectively.

Physiological Responses of One-year-old Zelkova serrata Makino Seedlings to Ozone in Open-top Chamber (Open-top chamber 내(內)에서 오존에 폭로(暴露)시킨 1년생(年生) 느티나무(Zelkova serrata Makino) 묘목(苗木)의 생리적(生理的) 반응(反應)에 관(關)한 연구(硏究))

  • Kim, Hyun Seok;Lee, Kyung Joon
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.424-431
    • /
    • 1995
  • This study was conducted to evaluate resistance and physiological responses of Zelkova serrata Makino seedlings to ozone in open-top chamber. One-year-old seedlings of Zelkova serrata were planted in pots in April and grown in greenhouse until August. The plants were transferred into two out-door open-top chambers with a dimension of 2.0 m in diameter and 2.0 m in height. First chamber served as a control and was supplied with ambient air. Ozone was added to the second chamber for 5 hours per day(10.00 AM-15.00 PM) for 23 consecutive days at 0.1 ppm. Each chamber housed 70 pots. Every two, three or five days after initiation of exposure, ten pots were randomly removed from the chamber and determined for the contents of chlorophyll a, b, total chlorophyll and ${\beta}$-carotene in the leaves. Photosynthesis and dark respiration were estimated by measuring $CO_2$ absorption in a gas exchange chamber and oxygen absorption by oxygen monitoring system, respectively. Superoxide dismutase(SOD) activity in the leaves was assayed by a xanthine oxidase method. First visible injury of translucent(water-soaked looking) spots appeared on the leaves 14 days after the initial exposure, and ozone accelerated senescence of old leaves. Contents of chlorophyll a and b decreased by 17%, and 31%, respectively, in ozone treatment two days after exposure. The decrease in chlorophyll b was greater than that of chlorophyll a. Content of ${\beta}$-carotene in ozone treatment decreased by 25% two days after initiation of exposure, but the reduction was recovered with time. Photosynthesis decreased by 45%, and the respiration increased by 28% in the ozone treatment. SOD activity started to increase 4 days after beginning of exposure and increased by 285% 7 days after exposure, and decreased to the level below the control treatment with the advancement of the visible injury.

  • PDF

Simultaneous Application of Platinum-Supported Alumina Catalyst and Ozone Oxidant for Low-temperature Oxidation of Soot (백금담지 알루미나 촉매와 오존 산화제 동시 적용에 의한 탄소 입자상 물질의 저온 산화반응)

  • Lee, Jin Soo;Lee, Dae-Won
    • Korean Chemical Engineering Research
    • /
    • v.56 no.5
    • /
    • pp.752-760
    • /
    • 2018
  • The lowering of temperature for combustion of diesel particulate matters (or diesel soot) is one of the important tasks in automotive industry that is searching for a way to meet up "high-fuel efficiency, low-emission" standard. In this study, it was discussed how the use of ozone over platinum-based catalyst promotes a low-temperature soot oxidation occurred at $150^{\circ}C$. The use of platinum catalyst did not increase oxidation rate largely but was very effective in improving the selectivity of carbon dioxide. The pre-oxidation of NO into $NO_2$ using ozone was rather crucial in improving the oxidation rate of soot at $150^{\circ}C$.

Physical Activity- and Alcohol-dependent Association Between Air Pollution Exposure and Elevated Liver Enzyme Levels: An Elderly Panel Study

  • Kim, Kyoung-Nam;Lee, Hyemi;Kim, Jin Hee;Jung, Kweon;Lim, Youn-Hee;Hong, Yun-Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.3
    • /
    • pp.151-169
    • /
    • 2015
  • Objectives: The deleterious effects of air pollution on various health outcomes have been demonstrated. However, few studies have examined the effects of air pollution on liver enzyme levels. Methods: Blood samples were drawn up to three times between 2008 and 2010 from 545 elderly individuals who regularly visited a community welfare center in Seoul, Korea. Data regarding ambient air pollutants (particulate matter ${\leq}2.5{\mu}m$ [$PM_{2.5}$], nitrogen dioxide [$NO_2$], ozone [$O_3$], carbon monoxide, and sulfur dioxide) from monitoring stations were used to estimate air pollution exposure. The effects of the air pollutants on the concentrations of three liver enzymes (aspartate aminotransferase [AST], alanine aminotransferase [ALT], and ${\gamma}$-glutamyltranspeptidase [${\gamma}$-GTP)]) were evaluated using generalized additive and linear mixed models. Results: Interquartile range increases in the concentrations of the pollutants showed significant associations of $PM_{2.5}$ with AST (3.0% increase, p=0.0052), ALT (3.2% increase, p=0.0313), and ${\gamma}$-GTP (5.0% increase, p=0.0051) levels; $NO_2$ with AST (3.5% increase, p=0.0060) and ALT (3.8% increase, p=0.0179) levels; and $O_3$ with ${\gamma}$-GTP (5.3% increase, p=0.0324) levels. Significant modification of these effects by exercise and alcohol consumption was found (p for interaction <0.05). The effects of air pollutants were greater in non-exercisers and heavy drinkers. Conclusions: Short-term exposure to air pollutants such as $PM_{2.5}$, $NO_2$, and $O_3$ is associated with increased liver enzyme levels in the elderly. These adverse effects can be reduced by exercising regularly and abstinence from alcohol.

A Study of Ozonation Characteristics of Bis(2-chloroethyl) Ether (Bis(2-chloroethyl) Ether (BCEE)의 오존산화 특성에 관한 연구)

  • Lee, Cheal-Gyu;Kim, Moon-Chan
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.610-615
    • /
    • 2010
  • In this study ozonation of bis(2-chloroethyl) ether (BCEE) in aqueous solution was performed in a laboratory scale batch reacter. The ozonation process of BCEE was carried out by bubbling ozone at the bottom of reactor containing the BCEE solution. Ozonation was almost complete after 80 min with an ozone concentration of $50{\pm}10mg/L$. Ozonation treatment efficiencies of BCEE were evaluated in terms of $BOD_5$, $COD_{Cr}$, and TOC. In the ozonation of BCEE a 62.79% decrease of the $COD_{Cr}$ and a 57.25% decrease of the TOC lead to biodegradable by-products ($BOD_5/COD_{Cr}$ = 0.39). The results of this research show that wastewaters containing non-biodegradable compounds, such as BCEE can be successfully treated by ozonation followed by bio-treatment. The pseudo first-order rate constants of the ozonation was $2.00{\times}10^{-4}sec^{-1}$ and the activation energy was $10.02kcal{\cdot}mol^{-1}$ at $30^{\circ}C$.

Analysis of Chemical and Meteorological Effects on the Concentration Difference of Photochemical Air Pollutants between Coastal and Inland Regions in Busan (부산시 해안 및 내륙지역에서 광화학 오염물질의 농도 차이에 영향을 주는 화학 및 기상조건 분석)

  • Sang, Sang-Keun;Shon, Zang-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1169-1182
    • /
    • 2008
  • The chemical and meteorological effects on the concentration variations of air pollutants ($O_3$ and its precursors) were evaluated based on ground observation data in coastal and inland regions, Busan during springs and summers of 2005-2006. For the purpose of this study, study areas were classified into 5 categories: coastal area (CA), industrial area (IA), downtown area (DA), residential area (RA), and suburban area (SA). Two sites of Dongsam (DS) and Yeonsan (YS) were selected for the comparison purpose between the coastal and inland regions. $O_3$ concentrations in CA and SA were observed to be highest during spring (e.g., 40 ppb), whereas those in DA and RA were relatively low during summer (e.g., $22\sim24$ ppb). It was found that $O_3$ concentrations in IA were not significantly high although high VOCs (especially toluene of about 40 ppb) and $NO_x$ ($\geq$ 35 ppb) were observed. On the other hand, the concentration levels of $O_3$ and $PM_{10}$ at the DS site were significantly higher than those at the YS site, but $NO_x$ was slightly lower than that at the YS site. This might be caused by the photochemical activity and meteorological conditions (e.g., sea-land breeze and atmospheric stagnance). When maximum $O_3$ (an index of photochemical activity) exceeds 100 ppb, the contribution of secondary $PM_{10}\;((PM_{10})_{SEC})$ to total observed $PM_{10}$ concentrations was estimated up to 32% and 17% at the DS and YS sites, respectively. In addition, the diurnal variations of $(PM_{10})_{SEC}$ at the DS site were similar to those of $O_3$ regardless of season, which suggests that they are mostly secondary $PM_{10}$ produced from photochemical reactions.

Particle collection performance of a separated two-stage electrostatic precipitator for subway air purification (지하철 공기질 개선을 위한 분리형 2단 전기집진기의 집진 특성 분석)

  • Kim, Ye-Sle;Lee, Yeawan;Kim, Yong-Jin;Han, Bangwoo;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.119-130
    • /
    • 2020
  • In this study, we developed a separated two-stage electrostatic precipitator applicable in a subway air conditioning system. We studied the characteristics of collection efficiency of 0.3 ㎛ particle and ozone generation at different charger sizes and gaps of collector plates. Also, we compared the performance of the two-stage ESP to the MERV 10 filter with the removal efficiency of 10% used in actual subway air conditioning system. The maximum collection efficiency of 0.3 ㎛ particle was 93% at A charger (600 mm×250 mm×600 mm) and 84% at B charger (330 mm×280 mm×330 mm). Especially, with voltages applied to chargers with collection efficiency of about 80% or more, the ozone concentration of two different chargers was 5 ppb to 35 ppb. Finally, the filter quality of the collector developed in this study was 400 times higher than that of the MERV 10 filter. Therefore, it was concluded that the two-stage ESP could be a promising PM removal device suitable for subway air conditioning system.

Two-Phase Chemical Oxidation of Pyrene

  • Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.247-253
    • /
    • 2007
  • Polycyclic aromatic hydrocarbons (PAHs) are a major concern because of their potential mutagenic and carcinogenic risks to human beings. One of these harmful, yet commonly observed PAHs is pyrene. Pyrene is one of the 16 PAHs listed by the United States Environmental Protection Agency as priority pollutants. The purposes of this research are to develop a method of pretreatment for PAH contaminants prior to a typical biological treatment and to demonstrate the biodegradablity of these compounds. Since pyrene is non-polar, hexane was chosen as a solvent to effectively dissolve pyrene. Pyrene solutions were treated with ozone, as it has hish oxidation capacity and electrophilic character. The intermediates and byproducts of pyrene were dissolved in alkaline water at pH 11.4 and neutralized to test for $BOD_5$, COD, and toxicity. These solutions were further ozonated and assessed of biodegradability. The first-order rate constant to was found to be between $0.121day^{-1}$ and $0.081 day^{-1}$, depending on the duration of reozonation. The $BOD_5/COD$ ratio was found to 0.66. The toxicity test showed that after 10 min of reozonation time, the byproducts and intermediates of pyrene were within the lion-toxic range of ${\pm}10%$ inhibition for E-Coli bacteria.

A Study on the Trends of Air Quality and Characteristics in Seosan Area of Korean Penninsula (서산지역의 대기질 경년변화 특성에 관한 연구)

  • Shon, Byung-Hyun;Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.779-786
    • /
    • 2008
  • This study was performed to evaluate the characteristics of current air quality and to examine the monthly and yearly variation of $SO_2,\;O_3,\;CO,\;NO_2$, and fine particulate matter(PM-10) concentration in Seosan for the period of 1998-2006. During the recent 3 years, from 2004 to 2006, the yearly mean concentration of $SO_2,\;NO_2$, and PM-10 remained stability but CO and $O_3$ are gradually decreased. The monthly mean concentration of $NO_2$, CO, and $SO_2$ were high in the winter season and decreased steadily to the summer season, but the maximum concentration of $O_3$ and PM-10 appeared in the springtime. The number of days exceeding 24-hour standards for PM-10 were 54 times at Dokgodri and 25 times at Dongmundong. The number of sampling days exceeding the 1-hour and 8-hour standards for $O_3$ were 68 and 210 times at Dongmundong and at Dokgotri 93 and 213 times, respectively.