• 제목/요약/키워드: oxygen ratio

검색결과 1,611건 처리시간 0.033초

2단 분류층 가스화기에서 합성가스 생성을 위한 석탄 슬러리 가스화에 대한 수치 해석적 연구 (Numerical simulation of gasification of coal-water slurry for production of synthesis gas in a two stage entrained gasifier)

  • 서동균;이선기;송순호;황정호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.417-423
    • /
    • 2007
  • Oxy-gasification or oxygen-blown gasification, enables a clean and efficient use of coal and opens a promising way to CO2 capture. The coal gasification process of a slurry feed type, entrained-flow coal gasifier was numerically predicted in this paper. The purposes of this study are to develop an evaluation technique for design and performance optimization of coal gasifiers using a numerical simulation technique, and to confirm the validity of the model. By dividing the complicated coal gasification process into several simplified stages such as slurry evaporation, coal devolatilization, mixture fraction model and two-phase reactions coupled with turbulent flow and two-phase heat transfer, a comprehensive numerical model was constructed to simulate the coal gasification process. The influence of turbulence on the gas properties was taken into account by the PDF (Probability Density Function) model. A numerical simulation with the coal gasification model is performed on the Conoco-Philips type gasifier for IGCC plant. Gas temperature distribution and product gas composition are also presented. Numerical computations were performed to assess the effect of variation in oxygen to coal ratio and steam to coal ratio on reactive flow field. The concentration of major products, CO and H2 were calculated with varying oxygen to coal ratio (0.2-1.5) and steam to coal ratio(0.3-0.7). To verify the validity of predictions, predicted values of CO and H2 concentrations at the exit of the gasifier were compared with previous work of the same geometry and operating points. Predictions showed that the CO and H2 concentration increased gradually to its maximum value with increasing oxygen-coal and hydrogen-coal ratio and decreased. When the oxygen-coal ratio was between 0.8 and 1.2, and the steam-coal ratio was between 0.4 and 0.5, high values of CO and H2 were obtained. This study also deals with the comparison of CFD (Computational Flow Dynamics) and STATNJAN results which consider the objective gasifier as chemical equilibrium to know the effect of flow on objective gasifier compared to equilibrium. This study makes objective gasifier divided into a few ranges to study the evolution of the gasification locally. By this method, we can find that there are characteristics in the each scope divided.

  • PDF

Shell 석탄가스화 복합발전 시스템의 성능해석 연구 (Performance Analysis of Shell Coal Gasification Combined Cycle systems)

  • Kim, Jong-Jin;Park, Moung-Ho;Song, Kyu-So;Cho, Sang-Ki;Seo, Seok-Bin;Kim, Chong-Young
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.104-113
    • /
    • 1997
  • 본 연구에서는 상용공정모사기인 ASPEN PLUS를 이용하여 건식탄공급, 산소사용 분류층 가스화기인 Shell가스화공정, 저온가스정제공정, GE MS7001FA가스터빈, 삼압.자연순환식 폐열회수보일러, 재열복수식 증기터빈 및 극저온 산소분리공정을 채용한 IGCC시스템에 대하여 성능해석 모델을 개발하고 시스템 성능해석을 위한 민감도분석을 수행하였다. 본 모델의 적정성은 설계조건에서 대상탄을 이용한 정상상태 성능해석 결과를 타 시뮬레이션 결과와 비교함으로서 검증하였다.$^{1)}$ . Illinois#6탄을 대상으로 수행한 시뮬레이션 결과는 투입되는 탄에 함유된 수분의 양이 증가함에 따라 가스화기의 온도가 감소하며, 회분 및 황이 많은 경우에 현열손실이 증가하여 시스템 효율이 감소하였다. 개발된 모델을 이용하여 가스화기의 운전압력, 증기/석탄비율 및 산소/석탄비율에 따르는 시스템의 민감도분석을 수행한 결과 운전압력 증가에 따라 가스화기 노내온도가 상승하며, 가연성가스(CO+H2) 생성율이 감소하였다. 증기/석탄비율 변화분석에서는 공급증기의 양을 변화시키면 가연성가스의 최고생성점이 보다 낮은 산소/석탄비율에서 나타남을 알 수 있었다. 또한 산소/석탄비율 변화분석에서는 증기/석탄 공급비율 0.2에서 산소/석탄 공급비율이 0.77인 경우에 가장 최적의 운전조건임을 알 수 있었다.

  • PDF

고유량 비강 캐뉼라 산소요법을 받은 소아중환자실 환아의 ROX Index와 ROX-HR Index 및 SpO2/FIO2 Ratio분석 (Analysis of ROX Index, ROX-HR Index, and SpO2/FIO2 Ratio in Patients Who Received High-Flow Nasal Cannula Oxygen Therapy in Pediatric Intensive Care Unit)

  • 최선희;김동연;송병은;유양숙
    • 대한간호학회지
    • /
    • 제53권4호
    • /
    • pp.468-479
    • /
    • 2023
  • Purpose: This study aimed to evaluate the use of the respiratory rate oxygenation (ROX) index, ROX-heart rate (ROX-HR) index, and saturation of percutaneous oxygen/fraction of inspired oxygen ratio (SF ratio) to predict weaning from high-flow nasal cannula (HFNC) in patients with respiratory distress in a pediatric intensive care unit. Methods: A total of 107 children admitted to the pediatric intensive care unit were enrolled in the study between January 1, 2017, and December 31, 2021. Data on clinical and personal information, ROX index, ROX-HR index, and SF ratio were collected from nursing records. The data were analyzed using an independent t-test, χ2 test, Mann-Whitney U test, and area under the curve (AUC). Results: Seventy-five (70.1%) patients were successfully weaned from HFNC, while 32 (29.9%) failed. Considering specificity and sensitivity, the optimal cut off points for predicting treatment success and failure of HFNC oxygen therapy were 6.88 and 10.16 (ROX index), 5.23 and 8.61 (ROX-HR index), and 198.75 and 353.15 (SF ratio), respectively. The measurement of time showed that the most significant AUC was 1 hour before HFNC interruption. Conclusion: The ROX index, ROX-HR index, and SF ratio appear to be promising tools for the early prediction of treatment success or failure in patients initiated on HFNC for acute hypoxemic respiratory failure. Nurses caring for critically ill pediatric patients should closely observe and periodically check their breathing patterns. It is important to continuously monitor three indexes to ensure that ventilation assistance therapy is started at the right time.

Electrical Characteristics of Solution Processed In-Ga-ZnO Thin Film Transistors (IGZO TFTs) with Various Ratio of Materials

  • 이나영;최병덕
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.293.2-293.2
    • /
    • 2016
  • The In this paper, we have fabricated the solution processed In-Ga-ZnO thin film transistors (IGZO TFTs) by varying indium and gallium ratio. The indium ratio of IGZO TFTs was changed from 1 to 5 at fixed gallium and zinc oxide atomic percent of 1:1 and gallium ratio was varied from 1 to 5 at fixed indium and zinc oxide atomic percent of 1:1. When the indium ratio was increased at fixed gallium and zinc oxide ratio of 1:1, threshold voltage was negatively shifted from 1.03 to -6.18 V and also mobility was increased from 0.018 to $0.076cm2/V{\cdot}sec$. It means that the number of carriers in IGZO TFTs were increased due to great formation of the oxygen vacancies which generate electrons. In contrast, when the gallium ratio was increased in IGZO TFTs with indium and zinc oxide ration of 1:1, the on/off current ratio was increased from $1.88{\times}104$ to $2.22{\times}105$. It is because gallium have stronger chemical bonds with oxygen than that with the zinc and indium ions that lead to the decreased in electron concentration.

  • PDF

Calculation of the air ratio in the case of firing gaseous fuels containing incombustibles

  • Cho, Kil-Won;Kunwoo Han;Park, Heung-Soo;Lee, Yong-Kuk;Lee, Kun-Hong
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1998년도 춘계 학술발표회 논문집
    • /
    • pp.43-48
    • /
    • 1998
  • A short-cut equation for the calculation of the air ratio in the case of firing gases containing incombustibles has been derived on the basis of mass balances. The new equation requires the oxygen concentration and the amount of carbon dioxide in the combustion gas, theoretical oxygen and air requirements, and the content of incombustibles other than carbon dioxide in the fuel for the air ratio calculation. By using the equation, a theoretically correct calculation of the air ratio has been enabled.

  • PDF

활성화 magnetite를 이용한 이산화탄소 분해와 메탄화에 관한 연구 (The Decomposition of Carbon-dioxide and Methanation with Activated Magnetite)

  • 임병오;김승호;박영구
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.183-190
    • /
    • 1999
  • Magnetite was synthesized with $FeSO_4$, and NaOH for the decomposition of carbon dioxide and for the study of the methane formation. The chemical equivalent ratio was changed from 0.5 to 1.50 for the magnetite synthesis. The chemical equivalent ratio was fixed in 1.00, and Nickel chloride and Rhodium chloride equally added and synthesized with the ratio was of 0.10~10.00 mole%. The crystal strucure of the synthesized magnetite was measured XRD. Putting synthesized magnetite in the reactor and using hydrogen gas oxygen-deficient magnetite was made. Injecting carbon dioxide in the reactor, the decomposition reaction was experimented. The formation of methane was confirmed injecting hydrogen gas in the reactor after carbon dioxide was decomposed.

  • PDF

열처리 온도 및 분위기 변화에 따른 Bi-2223 초전도 선재에서의 특성변화 (superconducting properties of Bi-2223 tapes with various heat treatment condition)

  • 하동우;이동훈;하홍수;오상수;김홍대;양주생;윤진국;최정규;권영길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.527-530
    • /
    • 2002
  • A lot of efforts have been focused on the optimization of PIT parameters for Bi-2223/Ag wire. In this paper, initial annealing of Bi-2223/Ag wire to transform Bi-2212 orthorhombic from Bi-2212 tetragonal Precursor was investigated. This initial annealing step at low oxygen partial pressure were to transform Bi-2212 orthorhombic structure and to reduce the formation of second phases at superconducting wire. However Bi-2223 Phases were appeared at higher annealing temperature. Critical currents(Je) of Bi-2223/Ag tapes were sintered at low oxygen Partial pressure were higher than that of the wires sintered at atmosphere condition. In order to investigate the effect of rolling reduction ratio, Bi-2223/Ag HTS tapes were rolled with different reduction ratio. There were no clear difference of Je and filaments shape with various rolling reduction ratio.

  • PDF

순산소를 이용한 유리 용해로의 연소특성에 관한 실험적 연구 (Experimental study on combustion characteristics of oxy-fuel glass melting furnace)

  • 김세원;안재현;김용모;신명철
    • 한국연소학회지
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 2004
  • The results of a series of experiments executed by using two pilot-scale oxy-fuel burners are presented. The oxy-fuel burners are designed for maximum capacity of 50,000kcal/hr, 200,000kcal/hr and installed in the test furnace. The effects of turn-down ratio, excess oxygen ratio, nozzle exit velocity, injection angle, and swirl vane angle on the combustion characteristic are investigated. Temperature distributions are measured using R-type and Molybdenum sheathed C-type thermocouple at various points of the flame. The results showed that maximum temperature and mean temperature increase with the increase of turn-down ratio and momentum. The maximum flame temperature was increased about 35% compared to the case of equivalent air operated condition. In addition, optimum burner type, excess oxygen ratio and nozzle characteristics are obtained for this oxy-fuel glass melting furnace.

  • PDF

Effects of endurance training for 4weeks on resting metabolic rate and excess post-exercise oxygen consumption in mouse

  • Jeon, Yerim;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • 운동영양학회지
    • /
    • 제16권2호
    • /
    • pp.113-122
    • /
    • 2012
  • This study assessed the amount of energy consumed and fat deposition after endurance training in order to review the effect of 4-week endurance exercise on resting metabolic rate of a mouse during and after exercise and the effect of exercise. A total of 19 seven-week-old ICR male mice were used as the study subject. Those mice were divided into sedentary group (Sed) and trained group (Tr) after a week of environment adaption. The Tr group was trained with endurance exercise five times a week for four weeks. Weight and the amount of food intake were daily weighed and resting metabolic rate and metabolic rate after exercise were assessed before starting exercise and on the fourth week after training. Metabolic rate during exercise were measured four weeks after training. At the end of breeding period, statistically significant difference was shown in weights of trained and sedentary groups (p < 0.05). During a resting period, no significant difference was shown in oxygen intake, respiratory exchange ratio, and the amount of carbohydrate and fat oxidized. Moreover, no significant difference was shown in excess post-exercise oxygen consumption (EPOC) of an hour period after training. In contrast, the maximal oxygen uptake (VO2 max) was approximately 11.1% higher in trained group after training compare to before. However, there was no significant difference in respiratory exchange ratio and carbohydrate and fat oxidization. During exercise, oxygen uptake, carbon dioxide production, and respiratory exchange ratio in energy metabolism during exercise showed no significant difference. However, significant difference was exhibited in the amount of fat oxidized in both groups. Summing up those results, endurance exercise could be concluded to be effective in weight control. However, weight loss is thought to be resulted from increase in fat oxidization during exercise unlike the conclusion made from previous studies where weight loss is prominently influenced by energy metabolism during a resting period and increased fat oxidation during post-exercise recovery. All experimental procedures were carried out at the Animal Experiment Research Center of Konkuk University. This study was conducted in accordance with the ethical guidelines of the Konkuk University Institutional Animal Care and Use Committee.

Effectiveness and Safety of High-Flow Nasal Cannula Oxygen Delivery during Bronchoalveolar Lavage in Acute Respiratory Failure Patients

  • Kim, Eun Jin;Jung, Chi Young;Kim, Kyung Chan
    • Tuberculosis and Respiratory Diseases
    • /
    • 제81권4호
    • /
    • pp.319-329
    • /
    • 2018
  • Background: Bronchoalveolar lavage (BAL) is a necessary procedure for diagnosis of various lung diseases. High-flow nasal cannula (HFNC) oxygen delivery was recently introduced. This study aimed to investigate the safety and effectiveness of HFNC oxygen supply during BAL procedure in patients with acute respiratory failure (ARF). Methods: Patients who underwent BAL while using HFNC at a partial pressure of oxygen in arterial blood/fraction of inspired oxygen ($PaO_2/FiO_2$; PF) ratio of 300 or below among patients who had been admitted from March 2013 to May 2017 were retrospectively investigated. Results: Thirty-three BAL procedures were confirmed. Their baseline PF ratio was $166.1{\pm}46.7$. $FiO_2$ values before, during, and after BAL were $0.45{\pm}0.12$, $0.74{\pm}0.19$, and $0.57{\pm}0.14$, respectively. Flow (L/min) values before, during, and after BAL were $26.5{\pm}20.3$, $49.0{\pm}7.2$, and $40.8{\pm}14.2$, respectively. Both $FiO_2$ and flow during and after the procedure were significantly different from those before the procedure (both p<0.001). Oxygen saturation levels before, during, and after BAL measured by pulse oximeter were $94.8{\pm}2.9$, $94.6{\pm}3.5$, and $95.2{\pm}2.8%$, respectively. There were no significant differences in oxygen saturation among the three groups. Complications of BAL procedure included transient hypoxemia, hypotension, and fever. However, there was no endotracheal intubation within 24 hours. Baseline PF ratio in "without HFNC" group was significantly higher than that in "with HFNC" group. There were no differences in complications between the two groups. Conclusion: The use of HFNC during BAL procedure in ARF patients was effective and safe. However, there were no significant differences in oxygen saturation level and complications comparing "without HFNC" group in mild ARF. More studies are needed for moderate to severe ARF patients.