• Title/Summary/Keyword: oxygen gas

Search Result 2,290, Processing Time 0.032 seconds

Changes in Quality Characteristics of Bell Pepper Packaged with Different Films (포장 조건에 따른 피망의 저장 중 품질 특성 변화)

  • 박우포;조성환;김철환
    • Food Science and Preservation
    • /
    • v.10 no.2
    • /
    • pp.131-135
    • /
    • 2003
  • Bell pepper was packed with several plastic films, and investigated the quality Characteristics such as gas composition, weight loss, microbial load, soluble solid content, ascorbic acid and color during storage at 10$^{\circ}C$. Cast polypropylene (CPP), low density Polyethylene (LDPE), Polyolefin (MPD, PD961) and linear low density polyethylene (LLDPE) were used for this purpose. Oxygen concentration inside packages generally showed a 10∼14% after 1∼2 weeks, but package with CPP maintained above 15% throughout the storage. Carbon dioxide concentration of CPP was above 2%, but other treatments showed below 2%. Weight loss of all treatments was below 3.0% after 5 weeks. Total microbial count showed a similar pattern compared to yeast and mold, and CPP maintained the highest microbial load after 3 weeks. Yellowness (b value) of bell pepper was generally increased throughout the storage, and MPD and PD961 were higher than other treatments.

Effect of Iodine-coated Bipolar Plates on the Performance of a Polymer Exchange Membrane (PEM) Fuel Cell (고분자 전해질 막 연료전지에서의 아이오딘이 코팅된 분리판의 성능 효과)

  • Kim, Taeeon;Juon, Some;Cho, Kwangyeon;Shul, Yonggun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.61-69
    • /
    • 2013
  • Polymer exchange membrane (PEM) fuel cells have multifunctional properties, and bipolar plates are one of the key components in these fuel cells. Generally, a bipolar plate has a gas flow path for hydrogen and oxygen liberated at the anode and cathode, respectively. In this study, the influence of iodine applied to a bipolar plate was investigated. Accordingly, we compared bipolar plates with and without iodine coating, and the performances of these plates were evaluated under operating conditions of $75^{\circ}C$ and 100% relative humidity. The membrane and platinum-carbon layer were affected by the iodine-coated bipolar plate. Bipolar plates coated with iodine and a membrane-electrode assembly (MEA) were investigated by electron probe microanalyzer (EPMA) and energy-dispersive x-ray spectroscopy (EDS) analysis. Polarization curves showed that the performance of a coated bipolar plate is approximately 19% higher than that of a plate without coating. Moreover, electrochemical impedance spectroscopy (EIS) analysis revealed that charge transfer resistance and membrane resistance decreased with the influence of the iodine charge transfer complex for fuel cells on the performance.

The Effect of $SO_2$ on the Degradation of Chlorophyll in Green perilla (Perilla frutescens Suwon No. 8) (($SO_2$ 에 의한 들깨(수원(水原) 8호(號))의 엽록체분해(葉綠體分解)에 대하여)

  • Kim, Jeong-Gyu;Lim, Soo-Kil
    • Korean Journal of Environmental Agriculture
    • /
    • v.6 no.2
    • /
    • pp.73-76
    • /
    • 1987
  • The effects of light, active oxygen, inorganic $SO_3\;^{-2}\;ion$, $SO_2$ fumigation duration, $SO_2$ concentration on the degradation of photosynthetic pigments in Green perilla (Perilla frutescens Suwon No. 8) fumigated by $SO_2$ were investigated inside a phytotron. The results were as follows: 1. With the increase of the $SO_2$ dosage, visible injury and the degradation of chlorophyll increased. 2. The degradation of chlorophyll b was less than that of chlorophyll a and the carotinoid was more easily degratated than chlorophyll b. 3. The degradation of chlorophyll by $SO_2$ fumigation was induced directly by $SO_2$, itself. 4. Light is necessary to the degradation of chlorophyll. $SO_2$ and $O_2^-$ made in the photolysis process of the water molecule were the major components in the degradation of chlorophyll.

  • PDF

CO/HO-1 Induces NQO-1 Expression via Nrf2 Activation

  • Kim, Hyo-Jeong;Zheng, Min;Kim, Seul-Ki;Cho, Jung-Jee;Shin, Chang-Ho;Joe, Yeon-Soo;Chung, Hun-Taeg
    • IMMUNE NETWORK
    • /
    • v.11 no.6
    • /
    • pp.376-382
    • /
    • 2011
  • Background: Carbon monoxide (CO) is a cytoprotective and homeostatic molecule with important signaling capabilities in physiological and pathophysiological situations. CO protects cells/tissues from damage by free radicals or oxidative stress. NAD(P)H:quinone oxidoreductase (NQO1) is a highly inducible enzyme that is regulated by the Kelch-like ECH-associated protein 1 (Keap1)/nuclear factor erythroid 2-related factor 2 (Nrf2)/antioxidant response element (ARE) pathway, which is central to efficient detoxification of reactive metabolites and reactive oxygen species (ROS). Methods: We generated NQO1 promoter construct. HepG2 cells were treated with CO Releasing Molecules-2 (CORM-2) or CO gas and the gene expressions were measured by RT-PCR, immunoblot, and luciferase assays. Results: CO induced expression of NQO1 in human hepatocarcinoma cell lines by activation of Nrf2. Exposure of HepG2 cells to CO resulted in significant induction of NQO1 in dose- and time-dependent manners. Analysis of the NQO1 promoter indicated that an antioxidant responsible element (ARE)-containing region was critical for the CO-induced Nrf2-dependent increase of NQO1 gene expression in HepG2 cells. Conclusion: Our results suggest that CO-induced Nrf2 increases the expression of NQO1 which is well known to detoxify reactive metabolites and ROS.

Formation of Calcareous Deposit on Steel Plate by using Waste Oyster Shell (강판상에 굴 패각을 이용한 탄산칼슘 피막의 형성)

  • Kim, Beomsoo;Kwon, Jaesung;Kim, Yeonwon;Lee, Myeonghoon;Yang, Jeonghyeon
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.531-535
    • /
    • 2017
  • Enormous amount of waste oyster-shell (OS) has a major disposal problem in coastal regions. OSs have attracted much attention for recycling, because these are mainly composed of calcium carbonate with rare impurities. In this study, we demonstrate the calcareous deposit films on steel plate by using OSs on the basic of cathodic protection technique. The composition of the OSs was analyzed by wavelength dispersive X-ray fluorescence spectrometer. Carbon dioxide gas was pumped into distilled water to make carbonic acid solution for dissolution of OS. The calcareous deposit was characterized by second electron microscope (SEM), energy dispersive X-ray analysis (EDX) and X-ray diffraction. Corrosion rates were estimated by measurements of anodic polarization and immersion test. It is confirmed that calcareous deposits on steel plate are formed under all condition of cathodic protection by using waste OS from the SEM and EDX results. Calcareous deposits on steel by OS provide good corrosion resistance by acting as a barrier to oxygen supply to the steel surface.

Characterization of Alpha-Ga2O3 Template Grown by Halide Vapor Phase Epitaxy (HVPE 방법으로 성장한 Alpha-Ga2O3의 특성 분석)

  • Son, Hoki;Ra, Yong-Ho;Lee, Young-Jin;Lee, Mi-Jai;Kim, Jin-Ho;Hwang, Jonghee;Kim, Sun Woog;Lim, Tae-Young;Jeon, Dae-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.357-361
    • /
    • 2018
  • We demonstrated a crack-free ${\alpha}-Ga_2O_3$ on sapphire substrate by horizontal halide vapor phase epitaxy (HVPE). Oxygen-and gallium chloride-synthesized Ga metal and HCl were used as the precursors, and $N_2$ was used as the carrier gas. The HCl flow and growth temperature were controlled in the ranges of 10~30 sccm and $450{\sim}490^{\circ}C$, respectively. The surface of ${\alpha}-Ga_2O_3$ template grown at $470^{\circ}C$ was flat and the root-mean-square (RMS) roughness was ~2 nm. The full width at half maximum (FWHM) values for the symmetric-plane diffractions, were as small as 50 arcsec and those for the asymmetric-plane diffractions were as high as 1,800 arcsec. The crystal quality of ${\alpha}-Ga_2O_3$ on sapphire can be controlled by varying the HCl flow rate and growth temperature.

Combustion Characteristics and Design of Fiber Mat Catalytic Burners (매트 형태 연소촉매를 사용하는 촉매버너의 구조와 연소특성)

  • Song, Kwang-Sup;Jung, Nam-Jo;Kim, Hee-Yeon
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.100-106
    • /
    • 2008
  • Flameless fiber mat catalytic burners have been known as an effective heat source in industrial drying processes since heat obtained from combustion can be transferred to absorptive body by far-infrared radiation. In order to extend the application of fiber mat catalytic burner, novel fiber mat catalytic burners were manufactured and combustion characteristics of them were investigated. For diffusive catalytic burners, the efficiency of combustion was significantly affected by the installation direction and the temperature of catalytic bed perimeter influenced on the diffusion rate of oxygen which determined the combustion efficiency of catalytic burner. It was seen in premixed catalytic combustion that air content in premixed fuel gas was optimized at slightly higher than theoretical amount of air. Combustion heat released higher than 70% by radiant heat in premixed catalytic combustion likewise diffusive catalytic combustion.

The Study of Pyrolysis Characteristics of Dioxin Precursor Chlorophenol (다이옥신 전구물질인 Chlorophenol 의 열분해에 관한 연구)

  • Jeong, Tae-Seop;Kim, Jong-Guk;Kim, Kyoung-Soo;Yoon, Byeng-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.179-185
    • /
    • 2000
  • In this study, we examined the movement of chlorophenol as a precursor of the dioxin in the after-combustion to minimize the creation and emission of dioxin in a municipal waste incinerator. The CPs was injected to the electric incinerator in temperature $300{\sim}500^{\circ}C$, using $N_2$ gas to control the reaction time, The oxygen quantity supplied into the $CP_s's$ isomer combustion was added with the value of experience formula. When the space velocity in reactor was 60~80/sec, the removal efficiency of CP was obtained in the presence of Mo-V catalyst and non catalyst. The efficiency in non-catalyst was 74% to 80% mono-CP, di-CP 55~66%, tri-CP 50~58%, while mono-CP 90~99.9%, di-CP 96~97%, tri-CP 76~99% in a catalyst. Consequently, it was shown that these were 20~30% more efficienct than those.

  • PDF

Computer Simulation for Smelting Tretment of Waste Casting Sand (폐주물사의 용융처리에 관한 Computer Simulation)

  • Chung, Won-Sub;Min, Dong-Jun;Kim, Yong-Ha
    • Resources Recycling
    • /
    • v.5 no.3
    • /
    • pp.24-30
    • /
    • 1996
  • The computcr s~mulatiun model in vanaus s~nelllng process for melling waste cashhg sand was developed by using energy and malcrial balance concept. This modcl can prcdict the coal, flux and oxygen conaumptron and thc volume and temperature of off-gas The ~niljor critical varlablcs for smclting process can be crplained by using the analysis of energy and malc~ialb alance. Thc Innst lmportarlt variables lor smelting process were h i ~ hpo st-combust~anr atla, high heat transfer crficiency and refractory pratcclion lechnalogy. For saving encrg), in this smelting proccss, selection of caw marerials i.e coal, flus was important, cspacially ubi~go f low volatile coal was prufitahle.

  • PDF

The Characteristics of a Superposed Discharge Type Ozonizer Using Vacuum Discharge Tube (진공 방전관을 이용한 고농도 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Chang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.60-67
    • /
    • 2005
  • The superposed discharge type ozonizer of high ozone concentration using vacuum discharge tube has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode), is a superposed silent discharge type ozonizer for which the AC high voltages applied to the central electrode within discharge tube and the internal electrode has a $180{[^\circ]}$ phase difference and for which the external electrode is a ground. Ozone is generated by overlapping silent discharge between central electrode and external electrode, and silent discharge between internal electrode and external electrode. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, high ozone concentration can be obtained 8840[ppm].