Study on the Electrode Characteristics for the Alkaline Water Electrolysis (알칼리 수전해용 전극에 관한 연구)

  • Choi, Ho-Sang;Yim, Doo-Soon;Rhyu, Cheol-Hwe;Kim, Jae-Chul;Hwang, Gab-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • Alkaline electrolysis needs the electrode having a low overvoltage and good corrosion resistance in alkaline solution such as KOH and NaOH, for the oxygen and hydrogen production. The commercial materials such as SUS(stainless steel)-316, Ni and NiFe were evaluated for the electrode in alkaline electrolysis. The test solution for the alkaline electrolysis used 1~9M NaOH and 1~9M KOH. The voltage increased with an increase of current density in each solution. As for the 15wt.% (about 5M) NaOH, the voltage of the tested electrode under the current density of 1.8A/$cm^2$ showed the almost same value. The voltage over the current density of 1.8A/$cm^2$ deceased in the order: Ni${\fallingdotseq}$NiFe$cm^2$ showed the almost same value. The voltage over the current density of 1.8A/$cm^2$ deceased in the order: NiFe${\fallingdotseq}$SUS-316. From the results, it was estimated that NiFe and Ni was suitable as the electrode for the alkaline water electrolysis using NaOH and KOH electrolyte.

Investigation on the Design Wave Forces for Ear-do Ocean Research Station II: Fluid Force in the Breaking Wave Field (이어도 종합해양과학기지에 대한 설계파력의 검토 II: 쇄파역에서의 유체력)

  • 전인식;심재설;최성진
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.4
    • /
    • pp.168-180
    • /
    • 2000
  • In the Part I, the three dimensional model testing with NNW deep water wave direction gave the results such that the occurrence of breaking waves over the peak of Ear-Do caused very small wave height at the structure position. But the measured wave forces were rather greater than the calculated forces based on deep water wave height. Furthermore, It was also perceived that the time series of the forces looked like corresponding to the case that waves were superimposed by an unidirectional current. In the present Part II, the current is presumed to be a flow secondly induced by breaking waves, and an extensive study to clarify the current in a quantitative sense is performed through numerical analysis and hydraulic experiment. The results showed that a strong circulation can surely occur in the vicinity of the structure due to radiation stress differentials given by the breaking waves. It was also recognized that the velocity of the induced current varied with the magnitude of energy dissipation rate introduced in the numerical analysis. The numerical analysis was tuned adjusting the dissipation rate so that the calculated wave field could closely match with the experimental results of Part I. The fluid force (in prototype) for the optimal match showed approximately 2.2% increased over the calculated value based on the deep water wave height (24.6m) whereas the force corresponding to the average of the experimental values showed the increase of about 13.0%.

  • PDF

Effect of Current Density on the Crystal Structure of Ni-W Alloys Prepared by Electrodeposition (Ni-W 합금도금의 결정구조에 미치는 전류밀도의 영향)

  • Kim, Won-Baek;Lee, Cheol-Gyeong;Lee, Jae-Cheon;Seo, Chang-Yeol
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.898-904
    • /
    • 1998
  • Ni-W alloys containing 10 to 50wt% W were prepared by electrodeposition. Tungsten content in the alloy increased with current density. X-ray diffraction analysis revealed that the alloy was crystalline phase when deposited at current densities lower than 50mA/${cm}^2$. Their crystal structure transformed to amorphous at higher current densities. In terms of tungsten content, the crystal -+ amorphous transition occurred at 40-46wt% which was identified by the 3 fold increase in the width of a diffraction peak. The lattice parameter of crystalline phase increased with W upto 40wt% which is higher than the solubility limit of W (about 30wt%) in Ni. Therefore, the alloys are considered to be Ni solid solution supersaturated with W. The amorphous Ni-W alloys were recrystallized by annealing them at temperatures over $400^{\circ}C$. This was evidenced by the appearance a strong [ 11 11 annealing texture. The supersaturated W was precipitated during the annealing at over $800^{\circ}C$. The current-density dependence of W content and crystallinity was utilized to produce alternating layers of crystalline (30wt% W) and amorphous (50wt%) phases which may exhibit unique mechanical and corrosion properties.

  • PDF

A Study on Control of Fume for Various Parameters in CO2 Welding (CO2 용접에서 용접변수의 변화에 따른 용접흄 제어방법에 관한 연구)

  • Oh, Kwang-Joong;Kim, Hyun-Soo;Shon, Byung-Hyun;Jee, Hae-Sung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.76-87
    • /
    • 1998
  • The concentration of welding fume was measured by 221 welders themselves in chassis frame workplace of the manufactory from February, 1, 1996 to May, 31, 1997. Welding parameters were the welding current and the distance between helmet and arc. Those two optimum conditions were proposed by excess probability analysis using logistic regression, so the best position in the workplace was proposed considering two factors to control the welding fume. The results are as followings; 1) The excess proability of welding fume TLV was over 99% in above 260 Amperes of welding current and also in below 30cm of distanced between helmet and arc. 2) The equation from logistic regression analysis using SPSS/PC+5.02 had the welding current as a independent variable and the excess of welding fume TLV as a dependent variable (p<0.05). Logit(welding fume TLV) = 0.1296 ${\times}$ wlding currnet - 28.8750 3) The equation from logistic regression analysis using SPSS/PC+5.02 had the distance between helmet and arc as a independent variable and the excess of welding fume threshold limit value a, a dependent variable (p<0.05). Logit (welding fume TLV) = -0.6809 ${\times}$ distance between helmet and arc +25.1665 4) Considering both cases or 2) and 3). the result equation is following. (p<0.05). Logit (welding fume TLV) = 0.1346 ${\times}$ welding current -0.3859 ${\times}$ distance between helmet and arc -15.7382 5) The excess probability of welding fume threshold limit value was 100% in above 240 Ampere of welding current. Thus, below 220 Ampere can be suggested to reduce the 40% number of welders who have a excess welding fume threshold limit value. 6) The excess probability of welding fume TLV was 100% in below 34cm of distance between helmet and arc. Thus, over 38cm can be suggested to reduce the 33% number of welders who have a excess welding fume TLV. 7) Considering both 5) and 6) cases, first of all, the best welding current can be 200 Ampere to have a below 15% of welding fume excess probability for the welders who works in distance of 34-37cm. Secondly, to have a below 30% excess probability of welding fume TLV, the working distance must be over 38cm in 220 Ampere and 32cm in 200 Ampere. 8) To reduce the average exposure concentration of welding fume ($8.21{\pm}5.83mg/m^3$), the movable local exhaust system equipped with flexible hoods can be used.

  • PDF

Analysis of the Melting Characteristics of a Blade Type Fuse Used for Vehicles Due to Overload (과부하에 따른 차량용 블레이드형 퓨즈의 용단특성 해석)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.38-43
    • /
    • 2010
  • The purpose of this study is to secure the basis for judgment on the cause of an accident by analyzing the melting characteristics of a blade type fuse used for vehicles due to overload. In order to increase the reliability of the test, it was conducted by connecting the electrical system with conditions similar to those of an actual vehicle to apply the load. Carbonization pattern experiment of fuse by outside flame applied Korean Standard (KS). The fuse melted by the overcurrent showed a smooth cross-section while the test terminals, clear plastic body, etc., burnt out by the external flame was badly deformed. When 185% of the rated current (27.8A) was applied to a cable of 15A rated current onto which an over-capacity fuse (20A) was installed, the fuse melting time was 217 seconds. In addition, when a load current of 28.8[A] (139%) was applied, the fuse's test terminal and terminal blade were not burnt out although foam was observed on some parts of the plastic body. When a load capacity of 28.2[A] (141%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melting time was approximately 10 seconds. When a load current of 35.8[A] (119%) was applied, the fuse's test terminal and terminal blade were not burnt out, although some parts of the plastic body was swelled. However, it was observed that the switch terminal melted if approximately six minutes lapsed under such conditions. When a load capacity of 39.4[A] (131%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melted in approximately 69 seconds, and the test terminal and terminal blade were not burnt.

Current concept for anti-inflammatory mechanism of acupuncture;based on the latest studies (침의 염증 제어 기전에 관한 최근 견해;최신 연구를 바탕으로)

  • Jo, Jong-Hyun;Ahn, Seong-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.25 no.2
    • /
    • pp.43-55
    • /
    • 2008
  • Objectives : The acupuncture has been in the classic arsenal of Oriental medicine over inflammatory diseases. Its physiological mechanism is not fully understood but being known better everyday. We reviewed several papers to describe current concepts over anti-inflammatory mechanism of acupuncture. Methods : Some computerized literature searches were done using the key words of 'acupuncture' AND 'Anti-inflammatory' in Medline via Pubmed between March 2007 and December 2007. Only rationally-designed studies were picked among practically associated materials. A well-known hypothesis on acupunctural physiology was adapted for integration. Result : 18 studies were selected. 17 studies were laboratory experiment and 1 was a clinical study. Data was classified into some comprehensive categories. Author's opinion was added at the end of each category. Study results supported the hypotheses on acupunctural physiology; Acupuncture has some influences on autonomic nerve system(ANS). And it stimulates several receptors from target cells like macrophage, and finally inhbits cytokines like TNF-${\alpha}$, IL-1${\beta}$ andIL-10 which are inflammation-mediated. Acupuncture increases the opioid releasing therefore relieves inflammation. And acupuncture inhibits cyclooxgenase(COX) but its mechanism is controversial until now. Conclusion : Current concepts over anti-inflammatory mechanism of acupuncture are as follows. Acupucture suppresses inflammation by stimulation of ANS, increasing of opioid releasing and inhibition of COX. But more studies are needed to fully describe the anti-inflammatory effect of acupuncture.

  • PDF

The numerical simulation on variation of phytoplankton maximum region in the estuary of Nakdong river -II. The numerical simulation on variation of phytoplankton maximum region- (낙동강 하구지역의 식물플랑크톤 극대역 변동에 관한 수직시뮬레이션 -II. 식물플랑크톤 극대역 변동의 수치시뮬레이션-)

  • 이대인
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.375-384
    • /
    • 2000
  • It is very important to interprete and simulate the variation of phytoplankton maximum region for the prediction and control of red tide. This study was composed of two parts first the hydrodynamic simulation such as residual current and salinity diffusion and second the ecological simulation such as phytoplankton distribution according to freshwater discharge and pollutant loads. Without the Nakdong river discharge residual current was stagnated in inner side of this estuary and surface distribution of salinity was over 25psu. On the contrary with summer mean discharge freshwater stretched very far outward and some waters flowed into Chinhae Bay through the Kadok channel and low salinity extended over coastal sea and salinity front occurred. From the result of contributed physical process to phytioplankton biomass the accumulation was occurred at the west part of this estuary and the Kadok channel with the Nakdong river discharge. When more increased input discharge the accumulation band was transported to outer side of this estuary. The frequently outbreak of red tide in this area is caused by accumulation of physical processes. The phytoplankton maximum region located inner side of this estuary without the Nakdong river discharge and with mean discharge of winter but it was moved to outer side when mean discharge of the Nakdong river was increased. The variation of input concentration from the land loads was not largely influenced on phytoplankton biomass and location of maximum region. When discharge was increased phytoplankton maximum region was transferred to inner side of the Kadok channel. ON the other hand when discharge was decreased phytoplankton maximum region was transferred to inner side of this estuary and chlorophyll a contents increased to over 20$\mu\textrm{g}$/L Therefore if any other conditions are favorable for growth of phytoplankton. decreas of discharge causes to increase of possibility of red tide outbreak.