• Title/Summary/Keyword: over-current

Search Result 5,914, Processing Time 0.043 seconds

A Study on the Influence of Change of Electrical Stimulation Time on Body Regions Affects on Threshold of People Over Age 60 (60세이상 노인의 신체 부위별 전기자극시간에 따른 역치 변화에 대한 연구)

  • Lee, Jae-Kap;Choi, Jung-Hyun
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.29-37
    • /
    • 2009
  • Background: The purpose of this study was influence of change of electrical stimulation time on body regions affects on electrical current threshold. Methods: The present study is to examine the effect of silver spike point (SSP) electrical stimulation (1Hz), transcutaneous electrical nerve stimulation (TENS, 100Hz), and interferential current therapy (ICT, 50Hz) from the low back and scapulodorsal and knee joint regions on stimulation-induced current thresholds from the elderly (over sixty) people (male:72, female:91) in senior welfare center. Result: The low back region, but not scapulodorsal and knee joint region, significantly increased the TENS and ICT, but not SSP, electrical stimulation, significantly increased the time-dependent current thresholds in elderly patients. Conclusion: Therefore, these results, in part, suggest that the TENS and ICT were shown to be a more adaptable method of stimulation, and that needed of the development of senile specialized physical therapy and the utilization of senior leisure facilities such as senior welfare center the others.

  • PDF

Leakage Current of Hydrogenated Amorphous Silicon Thin-Film Transistors (수소화된 비정질규소 박막트랜지스터의 누설전류)

  • Lee, Ho-Nyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.738-742
    • /
    • 2007
  • The variations in the device characteristics of hydrogenated amorphous thin-film transistors (a-Si:H TFTs) were studied according to the processes of pixel electrode fabrication to make active-matrix flat-panel displays. The off-state current was about 1 pA and the switching ratio was over $10^6$ before fabrication of pixel electrodes; however, the off-state current increased over 10 pA after fabrication of pixel electrodes. Surface treatment on SiNx passivation layers using plasma could improve the off-state characteristics after pixel electrode process. $N_2$ plasma treatment gave the best result. Charge accumulation on the SiNx passivation layer during the deposition of transparent conducting layer might cause the increase of off-state current after the fabrication of pixel electrodes.

  • PDF

ON THE CONSTRUCTION OF MDS SELF-DUAL CODES OVER GALOIS RINGS

  • HAN, SUNGHYU
    • Journal of Applied and Pure Mathematics
    • /
    • v.4 no.3_4
    • /
    • pp.211-219
    • /
    • 2022
  • We study MDS(maximum distance separable) self-dual codes over Galois ring R = GR(2m, r). We prove that there exists an MDS self-dual code over R of length n if (n - 1) divides (2r - 1), and 2m divides n. We also provide the current state of the problem for the existence of MDS self-dual codes over Galois rings.

Implementation of High Frequency Current Controller for Self-Sensing Induction Motors (유도전동기 자가 진단 및 상수 추정을 위한 고주파 전류 제어기 구현)

  • Kwon, Young-Su;Seok, Jul-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.144-146
    • /
    • 2007
  • High frequency voltage signal injection have been widely used but they have some problems like over current protection. High frequency current signal injection and feedback control are more stable than voltage signal injection. In this paper, high frequency current controller for self-sensing and parameter estimation of induction motors is presented.

  • PDF

The development of laser system for cancer (암치료용 레이저 시스템 개발)

  • 이동진;김주명;김선학;임현수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.08a
    • /
    • pp.154-155
    • /
    • 2001
  • A laser system for therapy of cancer is proposed in this paper. In order to accuracy and statistical output control we used the constant current control method and designed the power source to protect the resonator from the over -current, rush-current and electrical fault. The most important things are the radiation type for cancer therapy in laser system, we developed the radiation type of cw, pulse, and burst pulse. The experimental result show that laser beam power increase linearly from 100mW to 300mW for input current increasing and the exposure time.

  • PDF

To Ensure A Product Reliability The Study on Accelerated Stress Tests for Magnetic Switch Used in Power Distribution System (제품 신뢰성 확보을 위한 배전 계통에 사용되는 전자개폐기 가속스트레스시험에 관한 연구)

  • Ryu, Haeng-Soo;Park, Sang-Yong;Han, Gyu-Hwan;Kwon, Young-Il;Yoon, Nam-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.377-380
    • /
    • 2005
  • In this paper, accelerated stress test(AST) for Magnetic Switch (MS) are applied to assure specified reliability of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, AST for product assembly are developed in order to improve the weak point so that increase the product reliability. Also we will show the basic information for the accelerated life test(ALT). The proposed AST results and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in the world markets.

  • PDF

Preparation of ITO Thin Films for Display Application with $O_2$ Gas Flow Ratio and Input Current by FTS (Facing Targets Sputtering) System

  • Kim, H.W.;Keum, M.J.;Lee, K.S.;Kim, H.K.;Kim, K.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1477-1479
    • /
    • 2005
  • In this work, the ITO thin films were prepared by FTS (Facing Targets Sputtering) system under different sputtering conditions which were varying $O_2$ gas flow, input current at room temperature. As a function of sputtering conditions, electrical and optical properties of prepared ITO thin films were measured. The electrical, optical characteristics and surface roughness of prepared ITO thin films were measured. In the results, as increasing $O_2$ gas 0.1[sccm] to 0.7[sccm], resistivity of ITO thin film was increased with a decreasing carrier concentration, $O_2$ gas over 0.3[sccm] the carrier mobility have a similarly value. Transmittance of prepared ITO thin films were improved at increasing $O_2$ gas 0.1[sccm] to 0.7[sccm]. And transmittance of all of the prepared ITO thin films was over 80%. We could obtain resistivity $6.19{\times}10^{-4}[{\omega}{\cdot}cm]$, carrier mobility $22.9[cm^2/V{\cdot}sec]$, carrier concentration $4.41{\times}10^{20}[cm^{-3}]$ and transmittance over 80% of ITO thin film prepared at working pressure 1mTorr, input current 0.4A without any substrate heating.

  • PDF

A Study on Accelerated Life Tests for Magnetic Switch Used in Distribution System (배전선로에 사용되는 전자개폐기(Magnetic Switch)의 가속수명시험에 관한 연구)

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Kwon, Young-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.536-540
    • /
    • 2002
  • In this paper, accelerated life test (ALT) models and procedures for Magnetic Switch (MS) are developed and applied to assure specified reliability of the products at development phase and guarantee the life of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, ALT models for MS are developed using the relationship between stresses and life characteristics of products. Using the ALT models, we performed life tests and analyzed the tests results. The proposed ALT models and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in world markets.

  • PDF

Effect of Transcranial Direct Current Stimulation on Visuomotor Coordination Task in Healthy Subjects

  • Kwon, Yong Hyun;Cho, Jeong Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.6
    • /
    • pp.386-390
    • /
    • 2014
  • Purpose: We aimed to investigate whether visuomotor function would be modulated, when healthy subjects performed tracking task after tDCS application over the primary sensorimotor cortex (SM1) in the non-dominant hemisphere. Methods: Thirty four right-handed healthy participants were enrolled, who randomly and evenly divided into two groups, real tDCS group and sham control group. Direct current with intensity of 1 mA was delivered over SM1 for 15 minutes. After tDCS, tracking task was measured, and their performance was calculated by an accuracy index (AI). Results: No significant difference in AI at the baseline between the two groups was observed. The AI of the real tDCS group was significantly increased after electrical stimulation, compared to the sham control group. Two way ANOVA with repeated measurement showed a significant finding in a large main effects of time and group-by-repeated test interaction. Conclusion: This study indicated that application of the anodal tDCS over the SM1 could facilitate higher visuomotor coordination, compared to sham tDCS group. These findings suggest possibility that tDCS can be used as adjuvant brain modulator for improvement of motor accuracy in healthy individuals as well as patients with brain injury.

A clinical study of ADL and health related Behaviors of elders Aged 65 or over in An urban Area (도시지역 노인의 ADL과 건강관리에 대한 임상적 연구)

  • Hur, Young-Gu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.4 no.1
    • /
    • pp.45-58
    • /
    • 1998
  • This study was carried out to find out general characteristics and health-related behaviors of elders aged 65 or over and factors related to their activities of daily living. and thus to contribute to their health maintenance and promotion. The subjects were 200 elders who had resided at Tae Jean city, with males and females was scaled 1 : 3. To collect data for study, the field survey was conducted from March 20 to October 31, 1997 with questionaire. 1. 65.0% of the subjects were 65-75 years old, while 35.0% were 75 years old or over, 20.5% of them were illterate, 46.5% could read and write Korean. graduated from elementary school, and 11.5% middle school or higher level. 2. 28.5% of subjects perceived their current health status, 46.0% of men and 38.0% of women as fair, In genal elderly men perceived their health status better than elderly women. Among the subjects, 62.0% of men and 57.0% of women reported that they experienced one or more illnesses during the last year. 3. 76.0% of men and 33.0% of women were current smokers. 55.0% of current smokers. 55.0% of current make smokers smoked 11-12 cigarettes per day and 53.2% of current female smokers smoked less than 10 cigarettes per day. 4. 76.0% of men and 37.3% of women drank alchol currently. 5. 56.0% of men and 34.7% of women practiced regular exercise for their health maintenance and promotion. 6. In general, 38.5% of subjects needed other's assistance for doing one or more Activites such as doing heavy home work, Walking up and down stairs or walking half a mile. 7. Common disease of the subjects were hypertention, depenerative arthritis and diabetes mellitus in order.

  • PDF