• Title/Summary/Keyword: outside wall

Search Result 353, Processing Time 0.028 seconds

A Study on the Temperature Controlled Performance of Thermal Reflective Exterior Finishes (열반사성 외장마감재의 온도조절 성능에 관한 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck-Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.186-187
    • /
    • 2019
  • In modern times, due to the centralized urban structure, the interval between buildings is narrow and the increase of the heat island phenomenon due to the accumulation of the structure is becoming a social problem. In order to solve these problems, various materials for reducing the surface temperature of buildings are under study. Particularly, in the case of a wall part which is a part directly affected by the outside air of the building, it is a main structural part for determining the room temperature. The purpose of this study was to develop a material that can improve the thermal environment performance of the building by evaluating the temperature control performance of the exterior finishing material using the heat reflecting material as a method for controlling the temperature of the outer wall finishing material.

  • PDF

Immunochemical Localization of Tetrahydrocannabinol (THC) in Chemically Fixed Glandular Thrichomes of Cannabis (Cannabaceae)

  • Eun Soo Kim;Paul G. Mahlberg
    • Animal cells and systems
    • /
    • v.3 no.2
    • /
    • pp.215-219
    • /
    • 1999
  • Monoclonal antibody for delta-9-tetrahydrocannabiol (THC Ab), conjugated with protein A-gold, was employed as a probe to detect THC localization in the gland and subjacent cells of chemically fixed bracts of Cannabis. THC was detected in the outer wall of the disc cells, fibrillar matrix, the surface feature of secretory vesicles, and sheath throughout development of the secretory cavity. The probe was absent from vesicles. Label was also present in anticlinal walls of disc cells and walls of dermal and mesophyll cells. Little or no THC Ab was present in disc cells and none were detected in control tissues. This distribution pattern of THC Ab was similar to that in tissues prepared by high pressure cryofixation-cryosubstitution. Consistent association of THC with wall and wall-derived materials suggests that cannnabinoids are synthesized outside the plasma membrane and bound to a wall component, where-upon they are transported to the cavity with wall materials released from the disc cell wall during development of the secretory cavity.

  • PDF

A Comparison Analysis on Thermal Performance According to Shape of Steel Stud Applied to Steel House (스틸 하우스 적용 스틸 스터드의 형상에 따른 단열성능 비교 연구)

  • Jang, Cheol-Yong;Lee, Na-Eun;Um, Eun-Jung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.241-245
    • /
    • 2009
  • The dry wall using steel stud is used to buildings in the inside and outside of the country because it has the merit that application is possible to various architecture. The purpose of this study is to measure thermal performance of dry wall which uses steel stud transformed one by using measurement equipment to decrease heat bridge of steel stud and ensure heat performance as dry wall. As a comparative performance test result, dry wall which uses steel stud transformed one has a performance enhancement compare with the dry wall using general steel stud.

  • PDF

Examined of reinforcement for the fire protection of the outside insulation Urbantype Housing with flammable insulation material (가연성 단열재를 사용한 외단열 도시형 생활주택의 방화를 위한 보강재 검토)

  • Lee, Kwang-Hee;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.28-29
    • /
    • 2015
  • Due to the big fire in Uijeongbu, the status of construction, fireproof materials and structural method were examined to prevent fire propagation through outside insulation parts of urban living homes. Through research and experiments, the following results were obtained. It was confirmed that outside heat-insulation wall method was used in a large number of urban living homes which were made of materials and structures spreading fire easily.Through experiments, it was revealed that lightweight plate material, as a fireproof material, can save the cost as well as the period of construction and obtain more than 30 minutes of evacuation time which is twice the maximum evacuation time.

  • PDF

Numerical Analysis of Freezing Phenomena of Water in a U-Type Tube (U자형 배관 내 결빙에 대한 해석적 연구)

  • Park, Yong-Seok;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.52-58
    • /
    • 2019
  • This study numerically analyzed the icing process in a U-shaped pipe exposed to the outside by considering the mushy zone of freezing water. Numerical results showed that the flow was pulled outward due to the U-shaped bend in the freezing section exposed to the outside, which resulted in the ice wave formation on the wall of the bended pipe behind. At the same time, the formation of a corrugated ice layer became apparent due to the venturi effect caused by the ice. The factors affecting the freezing were investigated, including the change of the pipe wall temperature, the water inflow velocity, and the pipe bend spacing. It was found that, as a whole, the thickness of the freezing layer increased as the pipe wall temperature decreased. It was also found that the freezing layer became relatively thin when the inflow rate of water was increased, and that the spacing of the pipe bends did not significantly impact the change in the freezing layer.

Measurement of Thermal Characteristics of Electric Unit for Sancheon High-Speed Railcar (고속열차 산천 전장품 발열특성 측정)

  • Park, Won-Hee;Yun, Su-hwan;Park, Choonsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3672-3679
    • /
    • 2015
  • The heat generated by electrical components during train operation was estimated by measuring the wall temperature in a locomotive, as well as the temperature and speed of the air entering from the outside and then returning to the outside. The temperatures of the electrical components and wall surface in a high-speed train were measured using an infrared camera. The heat generated by the electrical components was exhausted to the outside through a duct installed on the ceiling of the high-speed train. Thus, the temperature and speed of this exhaust air were measured, as well as those of the air entering the locomotive from the outside. The temperatures at the surfaces of the electrical components and walls in the locomotive were also measured using an attachment-type temperature sensor. In addition, the measurement results were applied to analyze how the heat characteristics of the electrical components were affected by the train operation.

A Study on the Performance Evaluation of Waterproof Sealant Materials for the Exterior Wall of PC Apartment House (PC 공동주택 외벽용 방수 실란트 자재의 성능 평가 연구)

  • Ko, Hyo-Jin;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.221-222
    • /
    • 2023
  • In this study, the performance evaluation of waterproof sealant materials applied to the outer wall of PC apartment houses was conducted. The sealant for PC members must have resistance to movement, and since it is exposed to outside air, weather resistance and water resistance are required.

  • PDF

A Study on the Double-Wall Greenhouse Filled with Styrene Pellets (입자충전형 이중벽 온실에 관한 연구)

  • 이석건;이종원;이현우
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • This study was conducted to develope the automatic insulation system which control inside temperature of the greenhouse. For this purpose, the double- wall greenhouse and system which could automatically supply and discharge styrene pellets were constructed and abrasion of the pellets, blower ability, insulating property, transmittance and shading effect were analyzed by the experiments. The results obtained from this study can be summarized as follows : 1. It took an hour and fifteen minutes to supply and discharge about 2㎥ pellets in the experimental greenhouse. However, it is possible to reduce the operation time by proper selection of the blower and exhaust port, and by proper control of the supply and return pipe. 2. It was founded that the indirect delivery way was more profitable than the direct one in the supply and return of pellets. 3. When the transmittance was measured between 10 a.m. and 3 p.m., the average light transmissivity rate was 67%. 4. In winter nighttime, the inside temperature of the double- wall greenhouse with out the pellets was higher than the outside temperature by 3.4$^{\circ}C$ on an average. However, the inside temperature of the double - wall greenhouse with insulated area 73% was higher than the outside by one 6.6$^{\circ}C$ on an average, and the inside temperature of the greenhouse with insulated area 100% was higher than outside one by 13.5$^{\circ}C$ on an average. Therefore, it was proved that the insulating ability of the double - wall greenhouse in nighttime was excellent. 5. When the outside temperature was 36.9$^{\circ}C$ on an average, the inside temperature of the double- wail greenhouse with insulated area 100% was 3$0^{\circ}C$ on an average. As the inside temperature was lower than the outside one by 7$^{\circ}C$ on an average, we could know that the shading effects of the double- wall greenhouse were excellent in summer daytime.

  • PDF

Electron Microscopic Study of Protoplast Formation from the Conidiospore of Trichoderma koningii (Trichoderma koningii의 conidiospore로부터의 원형질체 생성에 관한 전자현미경적 연구)

  • Park, H.M.;Lim, H.M.;Hong, S.W.;Hah, Y.C.
    • Applied Microscopy
    • /
    • v.14 no.2
    • /
    • pp.38-51
    • /
    • 1984
  • Fine structure of dormant and swollen conidiospore from Trichoderma koningii and the mechanism of protoplasting from the conidiospore were studied by scanning and transmission electron microscopy. The cell wall of dormant conidiospore was two-layered structure which consisted of electron dense outer layer and electron transparent inner layer. After 8.5 hrs incubation. the conidiospore was swollen and the outer layer of cell wall shown unequal thickness and partial breakage. Protoplast was released through the pore which has been formed by the breakage of outer layer and dissolution of newly synthesized cell wall for germ-tube formation. Swollen conidiospore and protoplast in releasing process contained various cell organelles and vacuoles with electron dense materials. The protoplast contained looser cytoplasm and had no cell wall materials outside of plasmamembrane.

  • PDF

Design of RC dual system building using special seismic detail (내진특수상세를 적용한 RC 이중골조 건물의 설계)

  • Lee, Han-Seon;Ko, Dong-Woo;Sun, Sung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.190-193
    • /
    • 2006
  • The definition of the Dual system is that the total seismic force resistance is to be provided by the combination of the moment frame and the shear walls or braced frames in proportion to their stiffness and the moment frame shall be capable of resisting at least 25% of the design force in Korean Building Code 2005 (KBC 2005). But, the definition of moment frame is ambiguous whether the moment frame include the imaginary columns in the shear wall (Case I) or include only the columns outside the shear wall (Case II). 60-story RC building was designed as dual system for Case I and Case II, and the required strength and reinforcement are compared. Moment and axial capacity of the shear wall of Case II decreased about 5% due to the absence of the column in the shear wall. The requirement of upper and bottom reinforcement of slab in Case II increased 13% and 40%, respectively, when compared to those of Case I. The required longitudinal reinforcement in columns for Case II is about 1.5 times larger than that of Case I.

  • PDF