• Title/Summary/Keyword: orthodontics

Search Result 2,701, Processing Time 0.025 seconds

Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment

  • Oh, Eun-Ju;Nguyen, Thuy-Duong T.;Lee, Seung-Youp;Jeon, Young-Mi;Bae, Tae-Sung;Kim, Jong-Gee
    • The korean journal of orthodontics
    • /
    • v.44 no.5
    • /
    • pp.246-253
    • /
    • 2014
  • Objective: To evaluate the bioactivity, and the biomechanical and bone-regenerative properties of Ti6Al4V miniscrews subjected to anodization, cyclic precalcification, and heat treatment (APH treatment) and their potential clinical use. Methods: The surfaces of Ti6Al4V alloys were modified by APH treatment. Bioactivity was assessed after immersion in simulated body fluid for 3 days. The hydrophilicity and the roughness of APH-treated surfaces were compared with those of untreated (UT) and anodized and heat-treated (AH) samples. For in vivo tests, 32 miniscrews (16 UT and 16 APH) were inserted into 16 Wistar rats, one UT and one APH-treated miniscrew in either tibia. The miniscrews were extracted after 3 and 6 weeks and their osseointegration (n = 8 for each time point and group) was investigated by surface and histological analyses and removal torque measurements. Results: APH treatment formed a dense surface array of nanotubular TiO2 layer covered with a compact apatite-like film. APH-treated samples showed better bioactivity and biocompatibility compared with UT and AH samples. In vivo, APH-treated miniscrews showed higher removal torque and bone-to-implant contact than did UT miniscrews, after both 3 and 6 weeks (p < 0.05). Also, early deposition of densely mineralized bone around APH-treated miniscrews was observed, implying good bonding to the treated surface. Conclusions: APH treatment enhanced the bioactivity, and the biomechanical and bone regenerative properties of the Ti6Al4V alloy miniscrews. The enhanced initial stability afforded should be valuable in orthodontic applications.

Incorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties

  • Venugopal, Adith;Muthuchamy, Nallal;Tejani, Harsh;Anantha-Iyengar-Gopalan, Anantha-Iyengar-Gopalan;Lee, Kwang-Pill;Lee, Heon-Jin;Kyung, Hee Moon
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.3-10
    • /
    • 2017
  • Objective: Microbial aggregation around dental implants can lead to loss/loosening of the implants. This study was aimed at surface treating titanium microimplants with silver nanoparticles (AgNPs) to achieve antibacterial properties. Methods: AgNP-modified titanium microimplants (Ti-nAg) were prepared using two methods. The first method involved coating the microimplants with regular AgNPs (Ti-AgNP) and the second involved coating them with a AgNP-coated biopolymer (Ti-BP-AgNP). The topologies, microstructures, and chemical compositions of the surfaces of the Ti-nAg were characterized by scanning electron microscopy (SEM) equipped with energy-dispersive spectrometer (EDS) and X-ray photoelectron spectroscopy (XPS). Disk diffusion tests using Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans were performed to test the antibacterial activity of the Ti-nAg microimplants. Results: SEM revealed that only a meager amount of AgNPs was sparsely deposited on the Ti-AgNP surface with the first method, while a layer of AgNP-coated biopolymer extended along the Ti-BP-AgNP surface in the second method. The diameters of the coated nanoparticles were in the range of 10 to 30 nm. EDS revealed 1.05 atomic % of Ag on the surface of the Ti-AgNP and an astounding 21.2 atomic % on the surface of the Ti-BP-AgNP. XPS confirmed the metallic state of silver on the Ti-BP-AgNP surface. After 24 hours of incubation, clear zones of inhibition were seen around the Ti-BP-AgNP microimplants in all three test bacterial culture plates, whereas no antibacterial effect was observed with the Ti-AgNP microimplants. Conclusions: Titanium microimplants modified with Ti-BP-AgNP exhibit excellent antibacterial properties, making them a promising implantable biomaterial.

Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial

  • Rahman, Norma Ab;Wey, Mang Chek;Othman, Siti Adibah
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.11-20
    • /
    • 2017
  • Objective: This randomized controlled trial aimed to compare the stability of mandibular arch orthodontic treatment outcomes between passive self-ligating and conventional systems during 6 months of retention. Methods: Forty-seven orthodontic patients with mild to moderate crowding malocclusions not requiring extraction were recruited based on inclusion criteria. Patients (mean age $21.58{\pm}2.94years$) were randomized into two groups to receive either passive self-ligating ($Damon^{(R)}$ 3MX, n = 23) or conventional system (Gemini MBT, n = 24) orthodontic treatment. Direct measurements of the final sample comprising 20 study models per group were performed using a digital caliper at the debonding stage, and 1 month, 3 months, and 6 months after debonding. Paired t-test, independent t-test, and non-parametric test were used for statistical analysis. Results: A significant increase (p < 0.01) in incisor irregularity was observed in both self-ligating and conventional system groups. A significant reduction (p < 0.01) in second interpremolar width was observed in both groups. Mandibular arch length decreased significantly (p = 0.001) in the conventional system group but not in the self-ligating system group. A similar pattern of stability was observed for intercanine width, first interpremolar width, intermolar width, and arch depth throughout the 6-month retention period after debonding. Comparison of incisor irregularity and arch dimension changes between self-ligating system and conventional system groups during the 6 months were non-significant. Conclusions: The stability of treatment outcomes for mild to moderate crowding malocclusions was similar between the self-ligating system and conventional system during the first 6 months of retention.

Cone-beam computed tomography for the assessment of root-crown ratios of the maxillary and mandibular incisors in a Korean population

  • Choi, Sung-Hwan;Kim, Jung-Suk;Kim, Cheol-Soon;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2017
  • Objective: This retrospective, cross-sectional study aimed to establish reference data for normal crown and root lengths and the root-crown ratios (R/C ratios) for the mature maxillary and mandibular incisors in a Korean population by using cone-beam computed tomography (CBCT). Methods: We included 672 Korean patients (141 men and 531 women; mean age, $27.2{\pm}7.7years$) who underwent CBCT examinations during various dental treatments. Crown and root lengths and the R/C ratios of the maxillary and mandibular incisors were measured using CBCT data, which were analyzed to detect significant differences between demographic factors as well as sagittal and vertical skeletal or occlusal relationships. Results: Teeth of the same type in each half-arch were symmetrical. The mean R/C ratios varied from 1.1 to 1.2 for the maxillary incisors and from 1.3 to 1.4 for the mandibular incisors. Crown and root lengths were greater in men than in women, regardless of tooth type. Root lengths and R/C ratios for the mandibular incisors were significantly greater in patients with skeletal Class II malocclusion or an excessive overjet than in the other patients. The R/C ratios for the mandibular incisors were lower in patients with an open bite than in those with a normal or deep bite. Moreover, the R/C ratios for the mandibular incisors increased with age. Conclusions: The data obtained in our study can serve as reference values for crown and root lengths and the R/C ratios for the maxillary and mandibular incisors in the Korean population.

The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V)

  • Huang, Gui-Yue;Jiang, Heng Bo;Cha, Jung-Yul;Kim, Kwang-Mahn;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.306-312
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effect of commercially available fluoride-containing oral rinses on the corrosion behavior of titanium alloys, which are the main components of orthodontic miniscrews. Methods: Four commercially available oral rinses (solution A, pH 4.46/260 ppm fluoride; solution B, pH 4.41/178 ppm fluoride; solution C, pH 6.30/117 ppm fluoride; and solution D, pH 4.17/3.92 ppm fluoride) were tested on titanium alloy (Ti-6Al-4V) circular plates, and saline was used as the control. The open-circuit potential and potentiodynamic polarization of these materials were measured. Thereafter, all samples were evaluated under a field-emission scanning electron microscope. Results: Among the tested oral rinses, except solution D, the more the fluoride content was, the greater was the corrosion potential downtrend; the corrosion resistance of the titanium alloy sample was also lowered significantly (p < 0.05). Field-emission scanning electron microscopic analysis of the surface morphology of the titanium alloy samples revealed that all samples had some defects, crevices, or pitting after exposure to the oral rinses than before treatment. In particular, the samples in solution A showed the most changes. Conclusions: Commercially available oral rinses having a high fluoride concentration and a low pH may reduce the corrosion resistance of titanium alloys used in dental appliances such as orthodontic titanium miniscrews and brackets.

Comparison of treatment effects between four premolar extraction and total arch distalization using the modified C-palatal plate

  • Jo, Sung Youn;Bayome, Mohamed;Park, Justyn;Lim, Hee Jin;Kook, Yoon-Ah;Han, Seong Ho
    • The korean journal of orthodontics
    • /
    • v.48 no.4
    • /
    • pp.224-235
    • /
    • 2018
  • Objective: The purpose of this study was to compare the skeletal, dental, and soft-tissue treatment effects of nonextraction therapy using the modified C-palatal plate (MCPP) to those of premolar extraction (PE) treatment in adult patients with Class II malocclusion. Methods: Pretreatment and posttreatment lateral cephalographs of 40 adult patients with Class II malocclusion were retrospectively analyzed. The MCPP group comprised 20 patients treated with total arch distalization of the maxillary arch while the PE group comprised 20 patients treated with four PE. Fifty-eight linear and angular measurements were analyzed to assess the changes before and after treatment. Descriptive statistics, paired t-test, and multivariate analysis of variance were performed to evaluate the treatment effects within and between the two groups. Results: The MCPP group presented 3.4 mm of retraction, 1.0 mm of extrusion, and $7.3^{\circ}$ lingual inclination of the maxillary central incisor. In comparison, the PE group displayed greater amount of maxillary central incisor retraction and retroclination, mandibular incisor retraction, and upper lip retraction (5.3 mm, $14.8^{\circ}$, 5.1 mm, and 2.0 mm, respectively; p < 0.001 for all). In addition, the MCPP group showed 4.0 mm of distalization and 1.3 mm of intrusion with $2.9^{\circ}$ distal tipping of the maxillary first molars. Conclusions: These findings suggest the MCPP is an effective distalization appliance in the maxillary arch. The amount of incisor retraction, however, was significantly higher in the PE group. Therefore, four PE may be recommended when greater improvement of incisor position and soft-tissue profile is required.

Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial

  • Gelin, Emilie;Seidel, Laurence;Bruwier, Annick;Albert, Adelin;Charavet, Carole
    • The korean journal of orthodontics
    • /
    • v.50 no.6
    • /
    • pp.373-382
    • /
    • 2020
  • Objective: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainless-steel fixed retainers over a 12-month study period. Methods: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.

Part I. What drives Korean adults to seek orthodontic treatment: Reliability and validity of a measurement instrument for the perception of orthodontic treatment

  • Oh, Min-Hee;Kim, Eun-A;Park, Ae-Hyun;Kim, MinSoo;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.50 no.6
    • /
    • pp.363-372
    • /
    • 2020
  • Objective: To develop a standardized instrument to measure the level of cognition for orthodontic treatment in adults, and verify its reliability and validity for assessing perceptions of orthodontic treatment in adults. Methods: A total of 406 adults aged 19-64 years were surveyed by an internet research system. A tool was developed through the instrument development and verification stages. The data were analyzed by correlation analysis, exploratory factor analysis, confirmatory factor analysis, and Cronbach's α test. Results: The instrument consisted of 11 items covering four factors related to orthodontic treatment. Three items were related to general perception, four described the perception of the treatment for adults, two related to the treatment effects, and two related to the retention of orthodontic treatment. In the reliability test, Cronbach's α was 0.845 for the 11 items. In assessments for individual components, Cronbach's α was 0.764 for the general perception of orthodontic treatment, 0.705 for the perception of this treatment for adults, 0.707 for the effects of the treatment, and 0.701 for the retention of orthodontic treatment. Finally, a measurement instrument for the perception of orthodontic treatment in adults was designed to assess the 11 items on a four-point Likert scale. Conclusions: This study developed a standard measurement instrument for assessing the perception of orthodontic treatment in adults. The proposed instrument will enable additional studies on the influence of an adult's perception of orthodontic treatment on the decision to undergo treatment.

Characterization of dental phenotypes and treatment modalities in Korean patients with Parry-Romberg syndrome

  • Yim, Sunjin;Yang, Il-Hyung;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.50 no.6
    • /
    • pp.407-417
    • /
    • 2020
  • Objective: To investigate the dental phenotypes and treatment modalities (Tx-Mod) in Korean patients with Parry-Romberg syndrome (PRS) using longitudinal data. Methods: The samples consisted of 10 PRS patients, who were treated and/or followed-up at Seoul National University Dental Hospital between 1998 and 2019. Using a novel PRS severity index based on the numbers of the atrophy-involved area and asymmetry-involved item, we classified them into mild (n = 3), moderate (n = 2), and severe (n = 5). Dental phenotypes, including congenitally missing tooth (Con-Missing-Tooth), microdontia, tooth with short root (Short-Root), tooth with dilacerated root, and delayed eruption/impacted tooth, were investigated along with Tx-Mod. Results: The side of occurrence of all dental phenotypes showed 100% concordance with the side of PRS involvement. The most two common dental phenotypes were Con-Missing-Tooth and Short-Root (n = 29 and n = 17 in six patients). The sums of the average number of Con-Missing-Tooth and Short-Root increased from mild PRS to moderate PRS and severe PRS cases (1.0, 6.0, and 6.2). In terms of Tx-Mod, growth observation due to mild atrophy, fixed orthodontic treatment, and grafting were used for mild PRS cases. Tx-Mod for moderate PRS cases involved growth observation for surgery due to an early age at the initial visit. For severe PRS cases, diverse Tx-Mod combinations including unilateral functional appliance, fixed orthodontic treatment, growth observation, grafting, and orthognathic surgery were used. Conclusions: The novel PRS severity index may be useful to provide primary data for individualized diagnosis and treatment planning for PRS patients.

Histomorphometric analysis of microcrack healing after the installation of mini-implants

  • Shin, Soobin;Park, Pan-Soo;Baek, Seung-Hak;Yang, Il-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.62-68
    • /
    • 2015
  • Purpose: The goal of this study was to investigate the histomorphometric characteristics of the healing process of microcracks in the cortical bone after the installation of mini-implants (MIs). Methods: Self-drilling MIs were inserted into the tibial diaphysis of twelve adult male New Zealand rabbits. Four MIs per rabbit were placed randomly. The animals were divided into four groups according to the length of the healing period: group A was sacrificed immediately, group B was sacrificed after one week, group C was sacrificed after two weeks, and group D was sacrificed after four weeks. Cortical bone thickness was measured using micro-computed tomography, and histomorphometric analyses of the cumulative length of the microcracks (CLCr) and the total number of microcracks (NCr) were performed using hematoxylin and eosin staining. Results: The microcracks were radially and concentrically aligned in the peri-MI bone. The CLCr decreased significantly one week after the surgery, mainly due to healing of the concentrically aligned microcracks. The CLCr showed another significant decrease from two weeks after the surgery to four weeks after the surgery, mainly reflecting healing of the radially aligned microcracks. A statistically significant decrease in the NCr occurred as the microcracks healed from zero weeks to two weeks. However, no significant difference in the NCr was found between groups C and D. Conclusions: In order to improve the primary stability of MIs, delayed loading and a healing period of a certain length are recommended to ensure the optimal healing of microcracks and bone remodeling.