• Title/Summary/Keyword: optimum operation

Search Result 1,182, Processing Time 0.026 seconds

Experiences of Optimization of Flocculation Basins in Water Treatment Plants (정수장 응집공정의 최적운전조건 결정 사례)

  • Han, Moo-Young;Chung, Young-Kyun;Park, Yong-Hyo;Kim, Jeong-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.311-317
    • /
    • 2000
  • The operation of flocculation process and the evaluation thereof have been mainly based on G, t and $G{\times}t$ values which are available from design guidelines and texts. However, their suggested ranges are too wide to find the optimum condition specific to a particular water treatment plant and none of the existing method can be used to evaluate and suggest the optimum operational condition. Recently, a commercially available particle counter is found to be useful in determining the flocculation process based on the particle dynamics. The optimum condition is defined as one that best suits the purpose of flocculation; the number of small particles should decrease, while that of large particles should increase. The experiments were performed at two conventional water treatment plants in Korea, one with horizontal mechanical flocculators, and another with vertical type mechanical flocculators. In this paper, experiences to evaluate the flocculation process and to suggest the optimum operation condition will be presented. Although particle counting method is found to be beneficial compared to any other existing methods, the optimum condition is very much site-specific and should be evaluated at each water treatment plant for different conditions.

  • PDF

Influence of the Operation Modes on the Optimum Refrigerant Charge Amount of a Heat Pump (다양한 운전모드에서 물대물 열펌프의 성능 및 최적충전량 변화에 관한 연구)

  • Boahen, Samuel;Lee, Kwang Ho;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.2
    • /
    • pp.15-22
    • /
    • 2018
  • As heat pump application has been extending to residential, commercial, and industrial fields, the heat pump should have many operation modes. It is required to optimize refrigerant charge amount at all operation modes in order to enhance the annual performance of heat pumps. In this study, the performance analysis of the heat pump which has cooling, heating, cooling-hot water, heating-hot water, and hot water modes was executed with the variation of refrigerant charge amount. As the refrigerant charge amount changed, the maximum COPs of the heat pump at different operation modes were changed within ${\pm}10%$. Therefore, it is highly recommended to select optimum charge amount for the heat pump based on the analysis of annual load for each operation modes.

A Study on the Optimum Design of Cylinder Block in Swash Plate Type Oil Hydraulic Piston Pump

  • Baek, Il-Hyun;Cho, Ihn-Sung;Jung, Jae-Youn;Choi, Byung-In;Oh, Seok-Hyung
    • KSTLE International Journal
    • /
    • v.8 no.2
    • /
    • pp.29-34
    • /
    • 2007
  • Recently, requirements relating to performance, environment and noise in the oil hydraulic system of the heavy construction equipment have been reinforced continuously. In order to solve these technical trends, studies on the system compactness, operation under high pressure and great rotating speed, electronic control, substitute oil, and noise reduction have been progressed briskly. Among these recent studies, the system operation under high pressure is quite difficult to carry into effect due to mechanical limitations; that is, for realizing the system operation in the hydraulic pump under high pressure, the improvements or innovations on the design techniques, the manufacturing techniques, and the lubrication performance of the working oil are required. Accordingly, in this study, the stress distribution and optimum design factors under the maximum pressure were discussed by using stress analysis on the cylinder block of the hydraulic axial piston pump, which is one of the most important relative sliding regions.

An Optimal Conjunctive Operation of Water Transmission Systems from Multiple Sources with applying EPAnet and KModSim Model (KModSim 모형(模型)에 의한 도시지역(都市地域) 다중수원(多衆水源) 송수관망간(送水管網間) 최적(最適) 연계(連繫) 운영(運營) 연구(硏究))

  • Ryu, Tae-Sang;Cheong, Tae-Sung;Ko, Ick-Hwan;Ha, Sung-Ryong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.500-504
    • /
    • 2008
  • The objective of this paper is to evaluate the feasibility of using an optimization model as a effective way to search conjunctive operation scheme to meet two conditions; one is to minimize the electric cost for pumping and another is to meet the water demand for satisfying customers. The feasibility is confirmed as comparing the best combinations of pumps between multi-regional water supply networks from multiple sources which are obtained through an optimization modeling and EPAnet modeling. KModsim model, a network optimization model, was used to determine conjunctive operation scheme in the pipe system. KModsim, based on Lagrangian Relaxation algorithm, is useful for modeling network system and obtaining simultaneously pump combination and water allocation with given input option such as energy unit cost supplying from a source into a consumer, operating pumping combination. This study develops the procedure of determining optimal conjunctive operation scheme with using KModsim model. As a study region, the water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. The EPAnet hydraulic simulation result(Ryu et al, 2007, KSWW) gave input data for optimization model; energy unit price(won/$m^3$), water service available area etc.. It was assured that the combination of pump operation through optimum conjunctive operation is to be optimum scheme to obtain the best economic water allocation with comparison to the hydraulic simulation result such as electric cost and pump combination cases. The results obtained through the study are as follows. First, It was found that a well-allocated water supply scheme, the best combination of pump operation through optimum joint operation, promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. Second, an application of KModSim, a network model, gave the amount of water allocation from each source to a consumer with consideration of economic supply. Finally, in a service area available to supply through conjunctive operation of existing inter-regional water supply networks within short distance, a conjunctive operation is useful for determining each transmission pipeline's service area and maximizing the effectiveness of optimizations in pumping operation time.

  • PDF

On optimal correction of gunfire errors (포 사격오차의 최적 수정에 관한 연구)

  • 이양원;김영주;김경기;김경기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.109-112
    • /
    • 1989
  • Gun system operation is represented as a first-order Markov process, and an optimum linear filter is derived for closed-loop control of mean square error. Potential improvement is then estimated by contrasting the variance in performance and the auto correlation for open-loop system with that for the optimum linearly corrected process.

  • PDF

High Efficiency Design Considerations for the Self-Driven Synchronous Rectified Phase-Shifted Full-Bridge Converters of Server Power Systems

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.634-643
    • /
    • 2015
  • This paper presents a high frequency design approach for improving efficiency over a wide load range in the self-driven phase-shifted full-bridge converters for server power systems. In the proposed approach, a detailed ZVS analysis of the lagging leg switches in both the continuous conduction mode (CCM) and the discontinuous conduction mode (DCM) is presented. The optimum dead time and the determination of the appropriate operation mode are given for high efficiency according to the load conditions. Finally, the optimum operation conditions are defined to achieve a high-efficiency. A laboratory prototype operating at 80 kHz, rated 1 kW (12 V-83.3 A), is built to verify proposed theoretical analysis and evaluations. The experimental results show that the maximum efficiency is achieved as 95% and 83.5% at full load and 5% load conditions, respectively.

A Study on the Determination of Dosing Rate for the Water Treatment using Genetic-Fuzzy (유전-퍼지를 이용한 정수장 응집제 주입률 결정에 관한 연구)

  • 김용열;강이석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.7
    • /
    • pp.876-882
    • /
    • 1999
  • It is difficult to determine the feeding rate of coagulant in the water treatment process, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the genetic-fuzzy system was used in determining the feeding rate of the coagulant. The genetic algorithms are excellently robust in complex optimization problems. Since it uses randomized operators and searches for the best chromosome without auxiliary informations from a population consists of codings of parameter set. To apply this algorithms, we made the lookup table and membership function from the actual operation data of the water treatment process. We determined optimum dosages of coagulant(LAS) by the fuzzy operation, and compared it with the feeding rate of the actual operation data.

  • PDF

A Study on the Coagulant Dosage Control in the Water Treatment Using Real Number Genetic-Fuzzy (실수형 유전-퍼지를 이용한 정수장 응집제주입제어에 관한 연구)

  • Kim, Yong-Yeol;Kang, E-Sok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.312-319
    • /
    • 2004
  • The optimum dosage control is presumably the goal of every water treatment plant. However it is difficult to determine the dosage rate of coagulant, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the real number genetic-fuzzy system was used in determining the dosage rate of the coagulant. The genetic algorithms are excellently robust in complex optimization problems. Since it uses randomized operators and searches for the best chromosome without auxiliary informations from a population which consists of codings of parameter set. To apply this algorithms, we made the real number rule table and membership function from the actual operation data of the water treatment plant. We determined optimum dosages of coagulant(LAS) using the fuzzy operation and compared them with the dosage rate of the actual operation data.

Investigation on the Lab Scale Corrugator's Optimum Operating Conditions for Making Microflute Corrugated Paperboards (마이크로플루트 골판지생산을 위한 실험용 코루게이터의 최적 운전조건 탐색)

  • Cho, Yong-Min;Um, Gi-Jeung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.2 s.120
    • /
    • pp.54-59
    • /
    • 2007
  • Cereal, computer software, wine, small appliances, and fast foods are examples of products that have switched from folding carton to microflute corrugated paperboard. Microflute corrugated paperboards have their unique wonderful packaging characteristics that are driving forces for people to use more and more. Good strength property, excellent shock absorbing ability, and beautiful outer appearance of microflute corrugated paperboards go hand and hand with their environmental advantages. It is known that physical properties of microflute corrugated paperboards depend on not only properties of base paper but corrugator operating conditions. This study was carried out to investigate on the corrugator's optimum operating conditions for making micro flute corrugated paperboards. Lab-scaled micro flute corrugator was installed and run with systematic changes of operation conditions to investigate the effects of operation conditions on physical properties of micro flute corrugated paperboards.

The operation properties of DBD reactors in air pressure with varying the capacitance of reactors (정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.

  • PDF