An Experimental Study for Designing Electrostatic Precipitator: Focused on Collection Efficiency Variation per Area and corona Power

  • Kim, Jong-Ho;Cho, Yong-Kyun;Bong, Choon-Keun;Yun, Joong-Sup;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E2호
    • /
    • pp.79-84
    • /
    • 2000
  • The Electrostatic Precipitator is one of the most favorable device of particulate control systems because of the relatively higher collection efficiency and easier operation/maintenance. However, it requires very high initial coat especially for discharging electrodes and collecting plates. In dealing with such problems, development of optimum design can be one of the solutions. In this study, a bench-scale electrostatic precipitator was operated in terms of collection area and corona power, and its performances were analyzed focusing on collection efficiency. A result of this study, a more advanced approach for designing cost-effective precipitator by promoting corona power at a minimized collection area was proposed.

  • PDF

Expression of Modified Green Fluorescent Protein in Suspension Culture of Taxus cuspidata

  • Kim, Chang-Heon;Kim, Kyung-Il;Chung, In-Sik
    • Journal of Microbiology and Biotechnology
    • /
    • 제10권1호
    • /
    • pp.91-94
    • /
    • 2000
  • The suspension cells of Taxus cuspidata were transformed with Agrobacterium tumefaciens harboring binary vector pCAMBIE1302 encoding mgfp. Transient transfection efficiency was compared by using the fluoremetric measurement. The transient transfection efficiency was improved by transformation with DMSO and/or sonication treatment. Optimum conditions for DMSO and sonication treatment were 3% and 30sec, respectively. selection and maintenance of transformed cells were continued for 3 months. An insertion of the mgfp gene in transformed cells was detected by PCR and an expression of GFP confirmed by the western blot analysis.

  • PDF

전력용 변압기 예방진단 기준치 검토 (Investigation of the Preventive Diagnostic Criteria for Power Transformer)

  • 권동진;구교선;강연욱;우정욱;곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.592-596
    • /
    • 2005
  • The preventive diagnostic system prevents transformers from power failure by giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of transformer as well as to find location or cause of fault using accumulated data. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of preventive diagnostic system were settled but diagnostic algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the power transformer, investigated the preventive diagnostic criteria for power transformer.

  • PDF

저수지의 최적관리를 위한 생애체계 신뢰성 해석 연구 - 제체의 생애분포함수 유도 중심 - (Lifetime System Reliability for Optimum Management of Reservoirs for Irrigation)

  • 이준구;박광수;신수균;김관호;김명원;김한중
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.359-362
    • /
    • 2003
  • This research deriving the lifetime distribution function of embank as one of main components in reservoir was carried out by mining the data of precise safety diagnosis in 1995 to 2001 as one of researches that were performed for determining the propriety for making item at design for planning and considering optimal maintenance strategy for service life through acquiring the system function of reservoir as main resource for irrigation and analyzing the life cycle cost of it.

  • PDF

엔트로피에 의한 공동주택의 급수사용량에 관한 연구 (A Study on the Amount of Supply Water Consumption by Entropy in APT)

  • 안창환;공성훈;김종영
    • 한국주거학회논문집
    • /
    • 제11권3호
    • /
    • pp.125-136
    • /
    • 2000
  • The purpose of this study was to analyze water consumption in each apartment buildings influenced by several factors that are the income level of inhabitants, life style, the area apartments and climate. The automation of sanitary machines or facilities in recently built apartments has caused largely increases in amount of water consumption. Therefore, the design for water supply is very important for the maintenance of the optimum level or pressure of water supply. This study is based on the offer of basic data for improving the quality of water supply and employing the sanitary machines or sanitary facilities by analysis of amount increased of water consumption rapidly. Amount of water consumption data, the change in quality of entropy to the supply water pipe was analyzed and presented to indicate the necessary to basic materials for the design of an optimal water pipe.

  • PDF

스크롤기구를 적용한 신형식 스털링 엔진 (New-Type Stirling Engine Employing the Scroll Mechanism)

  • 김영민;신동길;이장희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1709-1716
    • /
    • 2003
  • Stirling engine is a heat engine with a high potential efficiency, multi-fuel capability, its low emission, quiet operation, very low maintenance requirement and long life. The Stirling cycle can ideally achieve optimum thermodynamic efficiency of the Carnot cycle. But the actual efficiency of practical reciprocating Stirling engine is much less than that of ideal Stirling cycle due to several mechanical limits. This paper presents a new-type Stirling engine employing the scroll mechanism superior to the reciprocating Stirling engine. The new-type Stirling engine is characterized as traits of continuous and wholly seperated compression and expansion, one-way flow, direct cooling and heating through the extensive surfaces of scroll wraps. By means of this traits, the new-type Stirling engine can achieve thermodynamic cycle closer to the ideal Stirling cycle and have many mechanical merits. Also, the new-type Stirling cycle can be applied as Stirling refrigerator and Duplex Stirling machine.

  • PDF

Using System Reliability to Evaluate and Maintain Structural Systems

  • Estes, Allen C.;Frangopol, Dan M.
    • Computational Structural Engineering : An International Journal
    • /
    • 제1권1호
    • /
    • pp.71-80
    • /
    • 2001
  • A reliability approach to evaluate structural performance has gained increased acceptability and usage over the past two decades. Most reliability analyses are based on the reliability of an individual component without examining the entire structural system. These analyses often result in either unnecessary repairs or unsafe structures. This study uses examples of series, parallel, and series-parallel models of structural systems to illustrate how the component reliabilities affect the reliability of the entire system. The component-system reliability interaction can be used to develop optimum lifetime inspection and repair strategies for structural systems. These examples demonstrate that such strategies must be based on the reliability of the entire structural system. They also demonstrate that the location of an individual component in the system has a profound effect on the acceptable reliability of that component. Furthermore, when a structure is deteriorating over time, the reliability importance of various components is a1so changing with time. For this reason, the most critical component in the early life of the structure may not tie the most critical later.

  • PDF

VE 기법을 이용한 철도 설계관리에 관한 기초연구 (Basic Study on Electrified Railway Design Management using VE(Value Engineering) Techniques)

  • 조래혁;황성광
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.849-855
    • /
    • 2005
  • Railway fields are complicatedly connected with engineering such as physics, civil engineering, architecture engineering, electrical engineering (Telecommunication, signal, catenary, system), machine engineering and performance phase of project in domestic railway can be divided with four steps : planning, design, supervision, construction. Value Engineering is needed to reduce the cost of long period construction duration and periodically maintenance. Currently, railway design is difficult to act optimum design due to limited time, short of manpower, downsized of design company. therefore, VE concept in Design must require In order to solve this problem. it is called Design Management. This paper presents both item of design management and total design management tool of practical aspects, and describes LCC (Life Cycle Cost) analyze process and accomplishment process for applying VE concept

  • PDF

종곡선/평면곡선 경합 시 승차감을 고려한 선형최적화에 관한 연구 (A Study on the Optimization of the Alignment Considering the Ride Comfort in the Case of the Superimposition of Vertical and Horizontal Curves)

  • 엄주환;양신추;최일윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1943-1950
    • /
    • 2010
  • Superimposition of horizontal and vertical curves may hamper the ride comfort and the running stability of train and largely affect the maintenance cost. However, in many cases, it's not easy to make a track plan because of the fixed points (bridge, tunnel, turnout, catenary system, etc.) to be avoided due to the geographic conditions or to be passed for utilization of existing structures. In this study, when the horizontal and vertical curves are superimposed, in order to optimize the horizontal curve in aspect of the ride comfort, the object function $P_{CT}$ was developed and verified by vehicle dynamic analysis. Also, the solution algorithm for simplified evaluation method was presented.

  • PDF

Tidal Current Power Generation by a Darrieus Type Water Turbine at the Side of a Bridge Pier

  • Kyozuka, Yusaku;Wakahama, Hisanori
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.99-104
    • /
    • 2006
  • There are several advantages to make use of a bridge pier for the tidal power generation. Current velocity increases near the pier, therefore the tidal power generation becomes more efficient because the power is proportional to the cubic of the current velocity. The pier is convenient for access and maintenance of the hydraulic turbine and the power unit. The project is now underway at the Ikitsuki Bridge in Tatsuno-Seto Strait of Nasasaki Prefecture, where the tidal current was measured by the bottom mount ADCP for almost one year. Model experiments for a Darrieus water turbine with two and three straight blades were carried out in the circulating water channel, in which the power coefficients of the turbine were obtained as a function of blade section and the attaching angle of a blade to the rotor. Those experimental results are discussed to obtain an optimum Darrieus turbine for tidal power generation.