• Title/Summary/Keyword: optimal site

Search Result 830, Processing Time 0.029 seconds

Field Study on Application of Reactive Zone Technology Using Zero-Valent Iron Nanoparticles for Remediation of TCE-Contaminated Groundwater (TCE 오염 지하수의 정화를 위한 나노영가철 기반 반응존 공법의 현장 적용성 연구)

  • Ahn, Jun-Young;Kim, Cheolyong;Hwang, Kyung-Yup;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.80-90
    • /
    • 2014
  • The laboratory and field studies were conducted to identify an optimal injection concentration of nanoscale zero-valent iron particles (NZVI) and to evaluate the applicability of NZVI-based reactive zone technology to the site contaminated with trichloroethylene (TCE) DNAPL (Dense Non-Aqueous Phase Liquid). The laboratory test found an optimal injection concentration of NZVI of 5 g/L that could remove more than 95% of 0.15 mM TCE within 20 days. Eleven test wells were installed at the aquifer that was mainly composed of alluvial and weathered soils at a strong oxic condition with dissolved oxygen concentration of 3.50 mg/L and oxidation-reduction potential of 301 mV. NZVI of total 30 kg were successfully injected using a centrifugal pump. After 60 days from the NZVI injection, 86.2% of the TCE initially present in the groundwater was removed and the mass of TCE removed was 405 g. Nonchlorinated products such as ethane and ethene were detected in the groundwater samples. Based on the increased chloride ion concentration at the site, the mass of TCE removed was estimated to be 1.52 kg. This implied the presence of DNAPL TCE which contributed to a higher estimate of TCE removal than that based on the TCE concentration change.

Assessment of Physical Habitat and the Fish Community in Korea Stream

  • Hur, Jun Wook;Joo, Jin Chul;Choi, Byungwoong
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The purpose of this study is to provide essential data necessary to assess ecological flow requirements by understanding habitat conditions for fish species through monitoring an ecological environment in the Korea stream (Dal Stream) and building related database. On-site surveys were conducted for identifying ecological and habitat conditions at the four monitoring sites. Fish sampling was carried out at the selected four sites (St.) during the period ranging from September, 2008 to September, 2009. At the four sampling sites, we measured water surface elevation, depth and velocity at the cross-sections. Optimal Ecological Flowrates (OEFs) were estimated using the Habitat Suitability Index (HSI) established for four fish species Zacco koreanus (St.1), Pungtungia herzi (St.2), Coreoleuciscus splendidus (St.3), and Zacco platypus (St.4) selected as icon species using the Physical HABitat SIMulation system (PHABSIM). Eighteen species (56.3%) including Odontobutis interrupta, Coreoperca herzi and C. splendidus were found endemic out of the 32 species in eight families sampled during this study period. The endangered species was collected Acheilognathus signifier, Pseudopungtungia tenuicorpa and Gobiobotia macrocephala, and this relative abundance was 9.4%. The most frequently found one was Z. platypus (31.3%) followed by C. splendidus (17.6%) and Z. koreanus (15.7%). The estimated IBI values ranged from 27.3 to 34.3 with average being 30.3 out of 50, rendering the site ecologically poor to fair health conditions. For C. splendidus (St.3), the dominant fish species in the stream, the favored habitat conditions were estimated to be 0.3-0.5 m for water depth, 0.4-0.7 m/s for flow velocity and sand-cobbles for substrate size, respectively. An OEFs of 8.5 m3/s was recommended for the representative fish species at the St.3.

Optimal Groundwater Development Estimation to Prevent Saltwater Intrusion in Western Jeju Island (제주 서부 지역 해수침투 방지를 위한 적정 양수량 산정기법)

  • Kim, Min-Gyu;Chang, Sun Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.527-535
    • /
    • 2018
  • Agricultural activities of western Jeju island has suffered from saltwater intrusion seasonally. Objectives of this study are to prove the occurrence of saltwater intrusion in the coastal aquifer and to consider a management plan using MODFLOW-family code SEAWAT model. Model results show that the saltwater-freshwater interface intrudes inland only a few meters and that upconing phenomenon is rather the cause of the severe disaster of the agricultural water contamination. This study selected Gosan area as a representative site to estimate optimal groundwater development regulation against upconing by seasonal pumping for agriculture. The suggested optimal groundwater development estimation method considers the groundwater levels of representative monitoring wells for regulatory alarms.

An application of LAPO: Optimal design of a stand alone hybrid system consisting of WTG/PV/diesel generator/battery

  • Shiva, Navid;Rahiminejad, Abolfazl;Nematollahi, Amin Foroughi;Vahidi, Behrooz
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.67-84
    • /
    • 2020
  • Given the recent surge of interest towards utilization of renewable distributed energy resources (DER), in particular in remote areas, this paper aims at designing an optimal hybrid system in order to supply loads of a village located in Esfarayen, North Khorasan, Iran. This paper illustrates the optimal design procedure of a standalone hybrid system which consists of Wind Turbine Generator (WTG), Photo Voltaic (PV), Diesel-generator, and Battery denoting as the Energy Storage System (ESS). The WTGs and PVs are considered as the main producers since the site's ambient conditions are suitable for such producers. Moreover, batteries are employed to smooth out the variable outputs of these renewable resources. To this end, whenever the available power generation is higher than the demanded amount, the excess energy will be stored in ESS to be injected into the system in the time of insufficient power generation. Since the standalone system is assumed to have no connection to the upstream network, it must be able to supply the loads without any load curtailment. In this regard, a Diesel-Generator can also be integrated to achieve zero loss of load. The optimal hybrid system design problem is a discrete optimization problem that is solved, here, by means of a recently-introduced meta-heuristic optimization algorithm known as Lightning Attachment Procedure Optimization (LAPO). The results are compared to those of some other methods and discussed in detail. The results also show that the total cost of the designed stand-alone system in 25 years is around 92M€ which is much less than the grid-connected system with the total cost of 205M€. In summary, the obtained simulation results demonstrate the effectiveness of the utilized optimization algorithm in finding the best results, and the designed hybrid system in serving the remote loads.

Determination of Optimal Mixing Ratio of Phosphorescent Pigment to Develop Phosphorescent Paint for Road Line Marking (도로의 축광차선 도료 개발을 위한 축광안료 최적 배합비 산정에 관한 연구)

  • Lee, Yong Mun;Kim, Sang Tae;Kim, Heung Rae
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2015
  • PURPOSES : This study was conducted to derive the optimum mixing ratio of phosphorescent pigment for the development of phosphorescent line marking. METHODS: In this study, we utilized a literature review and case study methodology, to describe the domestic and foreign state of practice for the production and mixing of phosphorescent pigment for use in line marking. The optimal mixing ratio was derived by comparing the reduction in luminance over time for the various phosphorescent pigment mixing ratios identified in the literature. In addition, performance and construction characteristics were analyzed using field testing techniques. RESULTS : The results were as follows: 1) the results of the luminance performance standards tests showed that all of the phosphorescence test specimens satisfied the phosphorescent fire protection standard. As the phosphorescent pigment mixing ratio increased, the luminance value increased, 2) the luminance reduction rate was minimum at the mixing ratio of 50%. However, when compared to a mixing ratio 40%, a small difference was recorded, the luminance reduction rate from the mixing ratio of 40% is judged as being converged. Therefore, in view of the economic efficiency, it was determined that the optimal mixing ratio was 40%, 3) as a result of construction on the field, a mixing ratio of 40% was found to have a higher luminance value than the general line marking for up to three hours after sunset, 4) it was found that the phosphorescent line markings without glass beads spraying had a higher luminance value than the phosphorescent line markings with glass beads spraying. CONCLUSIONS : Through the results of the basic experiments of the line markings obtained by blending a phosphorescent pigment, the results could be applied to play an important role in the development of phosphorescent line marking paint technology and in establishing application planning for on-site construction characteristics.

Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline (상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석)

  • Lee, Hohyun;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.834-840
    • /
    • 2021
  • The management and installation methods of pressure gauges in water supply pipeline are not efficiently regulated and their installations are different in each site. In this paper, various domestic and overseas documents are examined about the pressure gauge. In order to improve the efficiency of operation management such as pipeline network and pump operation, water pressure needs to be measured as accurate as possible, by which decision making for optimal pipe network can be achieved. To get the goal, the installation of pressure gauge should be reviewed about where and how to install. In this study, an optimal horizontal distance test is conducted, in which pressure value variation is monitored and analyzed according to up and down stream distances and valve flow control, and a optimal vertical position test is also analyzed by installing the pressure gauges vertically from the up(180°) to the bottom (0°) of the pipeline.

Stability Analysis of Piezoelectric Module and Determine of Optimal Burying Location (압전발전 모듈의 안정성 해석 및 최적 매립위치 결정)

  • In-Soo Son;Ji-Won Kim;Hong-Hoi Joo;Dae-Hwan Cho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.193-199
    • /
    • 2023
  • In this study, an analysis was conducted to analyze the structural stability of the piezoelectric power generation module and to determine the optimal burying hole interval for concrete, the installation site of the power generation module. A piezoelectric element refers to a functional ceramic having a piezoelectric direct effect that converts mechanical energy into electrical energy and a piezoelectric reverse effect. In the analysis of the piezoelectric power generation module, the load condition was applied with about 16 tons and a total of 10 wheels in consideration of the container trailer. The purpose was to evaluate the stability of major components of the piezoelectric power generation module through finite element analysis. In order to determine the optimal burying location of the concrete ground for burying the piezoelectric power generation module, the stability of the ground structure according to the distance of the holes was determined. As a result of the analysis, the maximum stress of the piezoelectric power generation module was generated in the support spring, showing a stress of about 276.7 MPa. It was found that the spacing of holes for embedding the piezoelectric power generation module should be set to a minimum of 100 mm or more.

Effect of Fibrin Sealant in Extended Lattisimus Dorsi Flap Donor Site: Retrospective Study (확장 광배근 피판거상 시 공여부 장액종의 예방을 위한 피브린 실란트의 효과에 대한 후향적 연구)

  • Cho, Hyun Woo;Lew, Dae Hyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.267-272
    • /
    • 2008
  • Purpose: Donor site seroma is the most common complication of extended latissimus dorsi flap for breast reconstruction. One of preventive treatments is to use the fibrin sealant in donor site before closure. Experimentally, it has been used successfully in the prevention of latissimus donor site seroma, but its clinical efficacy and results were very controversial. Thus, the purpose of this study is to evaluate the clinical efficacy and to determine the optimal dose of fibrin sealant. Methods: A retrospective study was done of patients operated under same surgical conditions by one operator with variable doses of fibrin sealant. The study group consisted of 60 consecutive patients who underwent breast reconstruction with extended latissimus flap reconstructions from January 2005 to December 2006. Patients were divided into 4 group by applied fibrin sealant amount(group 1=0 mL, group 2=1 mL, group 3=2 mL, group 4=4 mL). Retrospective data were obtained from total postoperative drainage amount, time from surgery to drain removal, and incidence and quantity of seroma formation in matched patients group. Results: Total drainage amount decreased relative to the amount of fibrin sealant. The seroma formation rate of 30% in the study group 4 was significantly less than group 1 rate of 71%(p<0.05). It was an improvement over the rates of as much as 79% described previously in the literature. Also, time from surgery to drain removal was shortened significantly in group 4 patients(p<0.05). Conclusion: The use of fibrin sealant in the extended latissimus dorsi flap donor site appears effective in preventing seroma. However, important factors to obtain lower seroma formation rates are proper techniques and proper amounts such as the authors suggested amount: $0.01mL/cm^2$ with spray type fibrin sealant.

On-site Inventory Management Plan for Construction Materials Considering Activity Float Time and Size of a Stock Yard (공정별 여유시간과 야적장 규모를 고려한 건설자재의 현장 재고관리 방안 연구)

  • Kim, Yong Hwan;Yoon, Hyeong Seok;Lee, Jae Hee;Kang, Leen Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.79-89
    • /
    • 2023
  • The inventory of many materials requires a large storage space, and the longer the storage period, the higher the potential maintenance cost. When materials are stored on a construction site, there are also concerns about safety due to the reduction of room for movement and working. On the other hand, construction sites that do not store materials have insufficient inventory, making it difficult to respond to demands such as sudden design changes. Ordering materials is then subject to delays and extra costs. Although securing an appropriate amount of inventory is important, in many cases, material management on a construction site depends on the experience of the site manager, so a reasonable material inventory management plan that reflects the construction conditions of a site is required. This study proposes an economical material management method by reflecting variables such as the status of the preceding and following activities, site size, material delivery cost, timing of an order, and quantity of orders. To this end, we set the appropriate inventory amount while adjusting related activities in the activity network, using float time for each activity, the size of the yard, and the order quantity as the main variables, and applied a genetic algorithm to this process to suggest the optimal order timing and order quantity. The material delivery cost derived from the results is set as a fitness index and the efficiency of inventory management was verified through a case application.

Examination of Improved Tetracycline Inducible Gene Expression System In Vitro (새로운 Tetracycline 유도적 유전자 발현 System의 In Vitro 검정)

  • Kwon, Mo Sun;Kim, Teoan;Koo, Bon Chul
    • Reproductive and Developmental Biology
    • /
    • v.37 no.3
    • /
    • pp.109-115
    • /
    • 2013
  • Until recently the most popular tetracycline-inducible gene expression system has been the one developed by Gossen and Bujard. In this study, we tested the latest version of same system and the results are summarized as follows: Compared with previous one, the difference of new system are minor changes of nucleotide sequences in transactivator and tetracycline response element (TRE) regions. Sensitivity to the doxycycline (a tetracycline derivative) was improved. Leakiness of GFP marker gene expression in non-inducible condition was significantly decreased. Higher expression of the marker gene was observed when the cells were fed with doxycycline-containing medium. Optimal insertion site of woodchuck posttranscriptional regulatory element (WPRE) sequence which was known to increase gene expression was different depending on the origin of cells. In chicken embryonic fibroblast, location of WPRE sequence at 3' end of TRE resulted in the highest GFP expression. In bovine embryonic fibroblasts, 3' end of transactivator was the best site for the GFP expression.