• Title/Summary/Keyword: operator mean

Search Result 178, Processing Time 0.023 seconds

Unaided Stapling Technique for Pure Single-Incision Distal Gastrectomy in Early Gastric Cancer: Unaided Delta-Shaped Anastomosis and Uncut Roux-en-Y Anastomosis

  • Suh, Yun-Suhk;Park, Ji-Ho;Kim, Tae Han;Huh, Yeon-Ju;Son, Young Gil;Yang, Jun-Young;Kong, Seong-Ho;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.15 no.2
    • /
    • pp.105-112
    • /
    • 2015
  • Purpose: Intracorporeal anastomosis is the most difficult procedure during pure single-incision distal gastrectomy (SIDG) that affects its generalization. We introduced unaided delta-shaped anastomosis (uDelta), a novel anastomosis technique, for gastroduodenostomy after pure SIDG, and compared the results with those of previously reported Roux-en-Y anastomosis (RY). Materials and Methods: Between March 2014 and March 2015, SIDG with D1+ lymph node dissection was performed for early gastric cancer through a 2.5-cm transumbilical incision without any additional port. uDelta was performed by the operator alone, without any intracorporeal assistance. Results: uDelta was performed on 11 patents, and uncut RY was performed on 5-patients without open or multiport conversion. R0 resection was performed in all cases. No significant differences were observed in mean age and body mass index between patients who underwent uDelta or RY. Mean operation times were $214.5{\pm}36.2$ minutes for uDelta and $240.8{\pm}65.9$ minutes for RY, which was not significantly different. Reconstruction time for uDelta was shorter than that for RY, with marginal statistical significance ($26.1{\pm}8.3$ minutes vs. $38.0{\pm}9.1$ minutes, P=0.05). There were no intraoperative transfusions, 30-day mortality, or anastomosis-related complications in either group. Average length of hospital stay was $8.2{\pm}1.9$ days in the uDelta group and $7.2{\pm}0.8$ days in the RY group (P=0.320). Conclusions: After carefully considering indications, uDelta can be a feasible and can be a reproducible reconstruction method after SIDG in early gastric cancer.

A Study on Accuracy in Determining the Hinge Axis Location (접번축(蝶番軸) 위치(位置) 결정시(決定時)의 정밀성(精密性)에 대(對)한 연구(硏究))

  • Kim, Choon-Ho;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.17-26
    • /
    • 1986
  • The purpose of this study was to investigate true hinge axis location with different times (8:00-9:00 A.M.,2:00-3:00 P.M.) and with experienced and inexperienced groups. 25 subjects, 23-27 years of age , with functionally acceptable occlusion, and no clinical signs of temporomandibular joint dysfunction were participated in this study. In this study arbitrary hinge axis point was located 13 mm anterior to the posterior margin of the tragus on a line from the center of the tragus to the outer canthus of the eye and then the true hinge axis point was located with T.M.J. hinge axis locator. The discrepancies of distance and the direction between true hinge axis point and arbitrary hinge axis point were studied according to times and two groups. The results obtained were as follows : 1. The mean distance from arbitrary hinge axis point to the true hinge axis point on the right and left sides was as follows : Experienced group: linear distance: $1.228{\pm}3.145mm$, vertical distance: $-1.128{\pm}2.515mm$, horizontal distance: $-0.484{\pm}1.806mm$. Inexperience group: linear distance: $1.628{\pm}3.158mm$, vertical distance: $-1.169{\pm}2.090mm$, horizontal distance: $-1.133{\pm}2.367mm$. Horizontal distance between experienced and inexperienced groups was significant statistically. (P<0.1) 2. True hinge axis points located within 5 mm of arbitrary hinge axis point were 86.7% in the experienced group and 84% in the inexperienced group. 3. For experienced operator A with time, the mean distance from arbitrary hinge axis point to true hinge axis point was as follows: Horizontal distance: AM: $-0.613{\pm}1.966mm$, PM: $-0.860{\pm}2.156mm$. Vertical distance: AM: $-0.886{\pm}2.518mm$, PM : $-1.226{\pm}2.660mm$. True hinge axis points had tendency to be located posterior-inferiorly to tragus-canthus line in the afternoon than in the morning, but there was not significant statistically. (P>0.1)

  • PDF

Comparing Validity of Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Disease Risk Factors in Korean Elderly (한국노인에서 심장혈관계 질환 위험인자에 대한 비만지표인 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 타당도 비교)

  • Moon Hyun-Kyung;Kim Eu-Gene
    • Journal of Nutrition and Health
    • /
    • v.38 no.6
    • /
    • pp.445-454
    • /
    • 2005
  • The purpose of this study was to compare the validity of obese index among body mass index (BMI), waist to hip ratio (WHR), and waist circumference (WC) and to determine which is the best in relation to cardiovascular disease (CVD) risk in Korean elderly more than 65 ages. Data from the 1998 Korean Health and Nutrition Survey were used (n=1017). Anthropometric indices and CVD risk factors were measured, and chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator Characteristic (ROC) curves were used in the analysis. Anthropometric values were decreased in both male and female when ages were goes up. In female elderly, it specially showed the characteristics of upper body fat and systolic blood pressure risk (p<0.05). Among life style factors the current smokers were prevalent in obese male (p<0.05), but not prevalent in female having obese or upper body fat. Also, person with upper body obesity have more exercise than that of normal group (p<0.01). Mean BMI values of the current smoker was lower than that of normal group in both sexes (p<0.01). Mean BMI value of person with other risk factors were higher than that of normal groups (p<0.05). Among 7 CVD risk factors in partial correlation analysis, WC had the highest correlation coefficient in 5 in male, whereas BMI in 4 in female. In ROC analyses of 12 risk factors and health conditions, the largest area under curve of obese indices for risk factors were WC>WHR>BMI in male and BMI>WHR>WC in female. The optimal cutoff values of each index (BMI : WHR : WC) for one or more risk factors were 19.02 : 0.84 : 71.3 in male and 19.04 : 0.88 : 85.6 in female. In conclusion, Most Korean elderly showed non-obese and abdominal obesity likewise other Asians. Also CVD risk factors were prevalent in Korean elderly within normal limits of obese indices. Therefore the upper body fat indices reflected in the aged whose muscle mass is replaced by fat must be used as an indicator of CVD risk together with BMI. Although WHR was the worst index based on partial correlation analysis and so located between BMI and WC in ROC curve analysis in both sexes, it need to be use with WC to screen the cardiovascular risk group.

Speed-Power Performance Analysis of an Existing 8,600 TEU Container Ship using SPA(Ship Performance Analysis) Program and Discussion on Wind-Resistance Coefficients

  • Shin, Myung-Soo;Ki, Min Suk;Park, Beom Jin;Lee, Gyeong Joong;Lee, Yeong Yeon;Kim, Yeongseon;Lee, Sang Bong
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.294-303
    • /
    • 2020
  • This study discusses data collection, calculation of wind and wave-induced resistance, and speed-power analysis of an 8,600 TEU container ship. Data acquisition system of the ship operator was improved to obtain the data necessary for the analysis, which was accomplished using SPA (Ship Performance Analysis, Park et al., 2019) in conformation with ISO15016:2015. From a previous operation profile of the container, the standard operating conditions of mean draft were 12.5 m and 13.6 m, which were defined with the mean stowage configuration of each condition. Model tests, including the load-variation test, were conducted to validate new ship performance and for the speed-power analysis. The major part of the added resistance of container ship is due to the wind. To check the reliability of wind-resistance calculation results, the resistance coefficients, added resistance, and speed-power analysis results using the Fujiwara regression formula (ISO15016:2015) and Computational fluid dynamics (Ryu et al., 2016; Jeon et al., 2017) analysis were compared. Wind speed and direction measured using an anemometer were used for wind-resistance calculation and the wave resistance was calculated using the wave-height and direction-data from weather information. Also, measured water temperature was used to calculate the increase in resistance owing to the deviation in water density. As a result, the SPA analysis using measured data and weather information was proved to be valid and able to identify the ship's resistance propulsion performance. Even with little difference in the air-resistance coefficient value, both methods provide sufficient accuracy for speed-power analysis. The differences were unnoticeable when the speed-power analysis results using each method were compared. Also, speed-power analysis results of the 8,600 TEU container ship in two draft conditions show acceptable trends when compared with the model test results and are also able to show power increase owing to hull fouling and aging. Thus, results of speed-power analysis of the existing 8,600 TEU container ship using the SPA program appropriately exhibit the characteristics of speed-power performance in deal conditions.

The role of the iliotibial band cross-sectional area as a morphological parameter of the iliotibial band friction syndrome: a retrospective pilot study

  • Park, Jiyeon;Cho, Hyung Rae;Kang, Keum Nae;Choi, Kun Woong;Choi, Young Soon;Jeong, Hye-Won;Yi, Jungmin;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • v.34 no.2
    • /
    • pp.229-233
    • /
    • 2021
  • Background: Iliotibial band friction syndrome (ITBFS) is a common disorder of the lateral knee. Previous research has reported that the iliotibial band (ITB) thickness (ITBT) is correlated with ITBFS, and ITBT has been considered to be a key morphologic parameter of ITBFS. However, the thickness is different from inflammatory hypertrophy. Thus, we made the ITB cross-sectional area (ITBCSA) a new morphological parameter to assess ITBFS. Methods: Forty-three patients with ITBFS group and from 43 normal group who underwent T1W magnetic resonance imaging were enrolled. The ITBCSA was measured as the cross-sectional area of the ITB that was most hypertrophied in the magnetic resonance axial images. The ITBT was measured as the thickest site of ITB. Results: The mean ITBCSA was 25.24 ± 6.59 ㎟ in the normal group and 38.75 ± 9.11 ㎟ in the ITBFS group. The mean ITBT was 1.94 ± 0.41 mm in the normal group and 2.62 ± 0.46 mm in the ITBFS group. Patients in ITBFS group had significantly higher ITBCSA (P < 0.001) and ITBT (P < 0.001) than the normal group. A receiver operator characteristic curve analysis demonstrated that the best cut-off value of the ITBT was 2.29 mm, with 76.7% sensitivity, 79.1% specificity, and area under the curve (AUC) 0.88. The optimal cut-off score of the ITBCSA was 30.66 ㎟, with 79.1% sensitivity, 79.1% specificity, and AUC 0.87. Conclusions: ITBCSA is a new and sensitive morphological parameter for diagnosing ITBFS, and may even be more accurate than ITBT.

Development of new artificial neural network optimizer to improve water quality index prediction performance (수질 지수 예측성능 향상을 위한 새로운 인공신경망 옵티마이저의 개발)

  • Ryu, Yong Min;Kim, Young Nam;Lee, Dae Won;Lee, Eui Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.2
    • /
    • pp.73-85
    • /
    • 2024
  • Predicting water quality of rivers and reservoirs is necessary for the management of water resources. Artificial Neural Networks (ANNs) have been used in many studies to predict water quality with high accuracy. Previous studies have used Gradient Descent (GD)-based optimizers as an optimizer, an operator of ANN that searches parameters. However, GD-based optimizers have the disadvantages of the possibility of local optimal convergence and absence of a solution storage and comparison structure. This study developed improved optimizers to overcome the disadvantages of GD-based optimizers. Proposed optimizers are optimizers that combine adaptive moments (Adam) and Nesterov-accelerated adaptive moments (Nadam), which have low learning errors among GD-based optimizers, with Harmony Search (HS) or Novel Self-adaptive Harmony Search (NSHS). To evaluate the performance of Long Short-Term Memory (LSTM) using improved optimizers, the water quality data from the Dasan water quality monitoring station were used for training and prediction. Comparing the learning results, Mean Squared Error (MSE) of LSTM using Nadam combined with NSHS (NadamNSHS) was the lowest at 0.002921. In addition, the prediction rankings according to MSE and R2 for the four water quality indices for each optimizer were compared. Comparing the average of ranking for each optimizer, it was confirmed that LSTM using NadamNSHS was the highest at 2.25.

An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory (자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가)

  • Jeong, Jee Yeon;Park, Seunghyun;Yi, GwangYong;Lee, Naroo;You, Ki Ho;Park, Junsun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF

Measurement of Operator Exposure During Treatment of Fungicide Difenoconazole on Grape Orchard (포도 과수원에서 살균제 Difenoconazole의 농작업자 노출량 측정)

  • Cho, ll Kyu;Park, Joon Seong;Park, So Hyun;Kim, Su Jin;Kim, Back Jong;Na, Tae Wong;Nam, Hyo Song;Park, Kyung Hun;Lee, Jiho;Kim, Jeong-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.4
    • /
    • pp.286-293
    • /
    • 2016
  • BACKGROUND: 18% of difenoconazole+iminoctadin triacetate microemulsion (3%+15%) formulation were mixed and sprayed as closely as possible to normal practice on the ten of farms located in the Youngju of South Korea. Patches, cotton gloves, socks, masks and XAD-2 resin were used to measure the potential exposure for applicators wearing standardized whole-body outer and inner dosimeter (WBD). This study has been carried out to determine the dermal and inhalation exposure to difenoconazole during preparation of spray suspension and application with a power sprayer on a grape orchard. METHODS AND RESULTS: A personal air monitor equipped with an air pump IOM sampler and cassette and glass fiber filter were used for inhalation exposure. The field studies were carried out in a grape orchard. The temperature and relative humidity were monitored with a thermometer and a hygrometer. Wind speed was measured using a pocket weather meter. All mean field fortification recoveries were between 97.3% and 119.6% in the level of 100 LOQ (limit of quantification) while the LOQ for difenoconazole was $0.025{\mu}g/mL$ using HPLC-UVD. The arms exposure to difenoconazole for the mixer/loader (0.0794 mg) was higher than other body parts (head, hands, upper body, legs). The exposure to difenoconazole in the legs for applicator (3.78 mg) was highest in the parts of body. The dermal exposure for mixer/loader and applicator were 0.02 and 2.28 mg on a grape orchard, respectively. The inhalation exposure during application was estimated as 0.02 mg. The ratio of inhalation exposure to dermal exposure was equivalent to 0.9% of the dermal exposure. CONCLUSION: The inhalation exposure for applicator indicated $18.8{\times}10^{-3}mg$, which was level of 0.9% of the dermal exposure (2.28 mg). Operator exposure (0.004 mg/kg bw/day) to difenoconazole during treatment for grape is calculated as 2.5% of the established AOEL (0.16 mg/kg bw/day).

A Study on the Effect of Organizational Trust of the Container Terminal Operators' Employee on Organizational Citizenship Behavior -Focusing on the Moderating Effect of Organizational Support- (컨테이너터미널 운영사 구성원의 조직신뢰가 조직시민행동에 미치는 영향 -조직적 후원의 조절효과를 중심으로-)

  • Kim, Ik-Seong;Seon, Hwa;Kim, Hyun-Deok
    • Journal of Korea Port Economic Association
    • /
    • v.39 no.1
    • /
    • pp.65-100
    • /
    • 2023
  • This study examines the effects of organizational trust of the container terminal operators' employee on organizational citizenship behavior and the moderating effect of organizational support in the relationship between the two variables. In order to efficiently achieve the purpose of this study, an empirical analysis was conducted by distributing a literature review and a questionnaire, and the results of the study are as follows... First, the organizational trust of the container terminal operators' employee was found to have a significant positive (+) effect on organizational citizenship behavior, and trust in the company appeared to be more important than trust in the superior, indicating trust in the institutional aspect. This means that formation has more influence on organizational citizenship behavior... Second, it was confirmed that the organizational support of the container terminal operators' employee can lead to active participation in organizational citizenship behavior through the expansion of educational compensatory support. Third, among the organizational support of container terminal operators, emotional support and educational compensatory support were found to have a partial moderating effect on the relationship between organizational trust and organizational citizenship behavior." Emotional support has a moderating effect on caring and active participation behaviors in the relationship between trust in the company and organizational citizenship behaviors, and a moderating effect on caring, active participation, and non-complaining behaviors in the relationship between trust in superiors and organizational citizenship behaviors. It was analyzed that there is Compensatory educational support has a moderating effect on altruistic, caring, active participation, and non-complaining behavior in the relationship between trust in the company and organizational citizenship behavior. It was analyzed that there was a moderating effect on active participation and non-complaining behavior. These analysis results mean that members' trust in the company further increases through the container terminal operator's emotional support and educational reward support. As uncertainty grows, it is very important to increase the trust of organizational members in the organization. sense of belonging to the organization, Emotional support that can increase immersion, improvement of work environment, provision of educational opportunities, and education-compensatory support such as a fair compensation system will increase organizational trust and induce effective organizational citizenship behavior to realize sustainable growth of the organization.

Hemodynamic changes associated with a novel concentration of lidocaine HCl for impacted lower third molar surgery

  • Ping, Bushara;Kiattavorncharoen, Sirichai;Durward, Callum;Im, Puthavy;Saengsirinavin, Chavengkiat;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.121-128
    • /
    • 2015
  • Background: The authors studied the hemodynamic effect influent by using the novel high concentration of lidocaine HCl for surgical removal impacted lower third molar. The objective of this study was to evaluate the hemodynamic change when using different concentrations of lidocaine in impacted lower third molar surgery. Methods: Split mouth single blind study comprising 31 healthy patients with a mean age of 23 years (range 19-33 years). Subjects had symmetrically impacted lower third molars as observed on panoramic radiograph. Each participant required 2 surgical interventions by the same surgeon with a 3-week washout period washout period. The participants were alternately assigned one of two types of local anesthetic (left or right) for the first surgery, then the other type of anesthetic for the second surgery. One solution was 4% lidocaine with 1:100,000 epinephrine and the other was 2% lidocaine with 1:100,000 epinephrine. A standard IANB with 1.8 ml volume was used. Any requirement for additional anesthetic and patient pain intra-operation was recorded. Post-operatively, patient was instructed to fill in the patient report form for any adverse effect and local anesthetic preference in terms of intra-operative pain. This form was collected at the seven day follow up appointment. Results: In the 4% lidocaine group, the heart rate increased during the first minute post-injection (P < 0.05). However, there was no significant change in arterial blood pressure during the operation. In the 2% lidocaine group, there was a significant increase in arterial blood pressure and heart rate in the first minute following injection for every procedure. When the hemodynamic changes in each group were compared, the 4% lidocaine group had significantly lower arterial blood pressure compared to the 2% lidocaine group following injection. Post-operatively, no adverse effects were observed by the operator and patient in either local anesthetic group. Patients reported less pain intra-operation in the 4% lidocaine group compared with the 2% lidocaine group (P < .05). Conclusions: Our results suggest that a 4% concentration of lidocaine HCl with 1:100,000 epinephrine has better clinical efficacy than 2% lidocaine HCl with 1:100,000 epinephrine when used for surgical extraction of lower third molars. Neither drug had any clinical adverse effects.