• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.033 seconds

Performance Analysis of an ORC System for Two Different Working Fluids (두 종류의 다른 작동유체가 ORC 시스템의 성능에 미치는 영향)

  • Chang, Hong-Soon;Song, Yeong-Kil;Han, Young-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.413-417
    • /
    • 2013
  • The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.

The Development of Hydraulic-Coupling Experimental Apparatus Using Brake Load and Prediction of Torque Performance (브레이크 부하를 이용한 유체커플링 실험장치 개발과 토크 성능 예측)

  • 박용호;김기홍
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.100-107
    • /
    • 2000
  • The hydraulic couplings have been widely used in industries, automobile, and power-station drives including ships. A mathematical analysis by which the design and application of hydraulic couplings are made is used in conventional design formulae and general roto-dynamic theories. The fluid flow of hydraulic couplings can be considered to have two component, one circumferentially about the coupling axis, and the other passing fluid from the pump to the turbine in the plane of the coupling axis. Tests have been carried out on the full-scale production coupling. The performance test consists of taking measurement of torque of the fluid coupling for three different amount of working fluid inside with various loads to the output shaft. The purpose of this research is to construct the experimental test equipments and to establish a series of performance test for the domestically developed hydraulic couplings, and to obtain experimental results which can be used to improve the performance of the hydraulic coupling and to solve the practical problems confronted in operation.

  • PDF

Image Comparison Using Directional Expansion Operation

  • Yoo, Suk Won
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.173-177
    • /
    • 2018
  • Masks are generated by adding different fonts of learning data characters in pixel unit, and pixel values belonging to each of the masks are divided into 3 groups. Using the directional expansion operators, we expand the text area of the test data character into 4 diagonal directions in order to create the boundary areas to distinguish it from the background area. A mask with a minimum average discordance is selected as the final recognition result by calculating the degree of discordance between the expanded test data and the masks. Image comparison using directional expansion operations more accurately recognizes test data through 4 subdivided recognition processes. It is also possible to expand the ranges of 3 groups of pixel values of masks more evenly such that new fonts can easily be added to the given learning data.

S-N Curve Estimation of a KTX Structure for an Accelerated Life Testing (가속수명시험을 위한 KTX 구조물의 S-N 선도 추정)

  • Jung, Dal-Woo;Choi, Nak-Sam;Park, Su-Han
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.384-389
    • /
    • 2008
  • An accelerated fatigue test is essentially required to maintain the reliability of the actual structure of KTX under operation conditions. However, actual fatigue life cannot be obtained if specimens are not adequate to the conventional fatigue test. Moreover component maker did not provide data of loading stress (S) - cycles at the failure (N). In this study, we suggest a prediction method of the S-N curve for establishing an accelerating test under various load levels. Load history was acquired from the field tests. A Rainflow method was used on the cycle counting of the field load data, and then, an S-N curve was obtained through the iteration process under the condition that the damage index satisfies to 1 in the Miner's rule.

  • PDF

Study on Regenerative Energy Storage System in K-AGT Test Track (경량전철 시험선에서의 에너지저장시스템 연구)

  • Cho, Hong-Shik;Ryu, Sang-Hwan;Hwang, Hyeon-Chyeol;Lee, An-Ho;Kim, Gil-Dong;Lee, Han-Min
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.208-210
    • /
    • 2008
  • LRT System Application Project is performed for the purpose of technical advancement and stabilization of K-AGT system from the viewpoint of practical use and commercialization. For those purpose, the performance test and evaluation procedure for K-AGT signaling system are developed, and the scheme of verifying the performance and function of signaling system under multi-train and driverless control environment is being conducted. For the multi-train operation in K-AGT test track, we applied the regenerative energy storage system in addition to the existing electric facilities. This paper present the design, manufacturing, and testing results of regenerative energy storage system.

  • PDF

KSLV-I Assembly Complex System Design (KSLV-I 조립콤플렉스 시스템 설계)

  • Jin, Seung Bo;Park, Jung Ju
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.37-41
    • /
    • 2006
  • The KSLV-I satellite launch vehicle will be launched in a space center currently under construction. The Space Center which is an advance post base of space development of Korea is located on Oenaro island in Kohung, South Cholla Province. A Ground Complex of the Space Center consists of an AC(Assembly Complex), a LC(Launch Complex), and a MCC(Mission Control Center). Assembly and test facilities are located in the AC in which stage assembly, integrated assembly, check-up, certification test, and pre-launch test are made effectively. A launch pad, fuel supply facilities, a launch control center and associated supporting facilities are located in the LC, and the MCC has control over the space center. These ground complex facilities have diverse forms of an interface with mechanical device, electric device, and etc. These should also provide optimum condition and performance during launch operation processes of the launch vehicle. This paper introduces the result of R&D for the AC of the ground complex performed during system design period.

  • PDF

A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant (신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Chung, H.T.;Jung, Y.B.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF

A Study on the Pressure Pulsation Reduction for a Hydraulic Clutch Operating System (유압식 클러치 조작기구의 압력맥동저감에 대한 연구)

  • Lee, Choon-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.93-99
    • /
    • 2008
  • The clutch is a subcomponent of the transmission that is designed to engage and disengage power flow between the engine and the transmission. Recently, the engine power of automobile has been continuously increased because of customer's demand for the bigger one. As the engine power is increased, the vibration transmitted to the hydraulic clutch operating system has been increased. Therefore the demand for the reduction of clutch pedal vibration during the operation of the clutch system has been increased. This paper describes the pressure pulsation reduction characteristics of the damper cylinder which is applied to the hydraulic clutch operating system. And the purpose of this study is to confirm the availability of a simulation model and investigating the test results of hydraulic clutch operating system. The test results are compared with the simulation results. Therefore it may be concluded that the simulation model and test results will be very useful f3r the design of hydraulic clutch damper cylinder.

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.

A study on Requirements of the Test Flight Safety for a 350m Unmanned Airship (50m급 무인비행선 시험비행 안전성 요구사항에 관한 연구)

  • Jeong, B.G.;Shin, D.W.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.12 no.2
    • /
    • pp.1-15
    • /
    • 2004
  • In this study, we analyze technical requirements for a 50m unmanned airship order to assure safety in the test flight operation. The 50m class unmanned airship developed by Airship Group in Korea Aerospace Research Institute(KARI). The 50m class unmanned airship was developed as a scale-down model of 200m class stratosphere unmanned airship. This study reviews specifications and characteristics of 50m class unmanned airship and develops Airworthiness Requirements on the basis of current effective Aviation Act, Airworthiness standards, and relevant international documents. The developed requirements can be applied to the safety assessment of the 200m class stratosphere unmanned airship.

  • PDF