• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.038 seconds

Four-axis CAM module for NC machining of rotational-free-surface (회전형상의 자유곡면가공을 위한 4축 CAM 모쥴의 개발)

  • 서석환;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.175-180
    • /
    • 1990
  • Rotational-free-surface (RFS) is a special type of free surface whose two boundaries coincide. For NC machining of PFS, a rotational axis as well as three Cartesian axes are required. In this paper, we develop a four-axis CAM module consisting of: a) Geometric modeling of RFS, b) CL-data generation, and c) Graphic simulation of machining operation. To test the validity and effectiveness of the developed module, several test cuts are made with Bridgeport CNC milling machine and compared with the graphic simulation.

  • PDF

Cooling Test of The HTS Power Cable (초전도케이블 냉각시험)

  • 염한길;고득용;홍용주;김익생;김춘동;김도형
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.295-297
    • /
    • 2003
  • Cryogenic systems is requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen or sub-cooled LN2. HTS power cable is needed for sufficient refrigeration to overcome its low temperature heat loading. This loading typically comes in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper is a explanation for the cooling test of 10m HTS power cable.

  • PDF

A Study on the Flight Simulator Certification System (비행 시뮬레이터 인증제도 연구)

  • Kim, Chang-Young;Choi, Ki-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.36-40
    • /
    • 2011
  • In this report US and Korea civil and military simulator certification system is researched, and a plan for improvement is proposed. Korean simulator certification system should adopt FAA's system and improve upon it. Certification criteria should have a basis on FAA certification criteria and add military operation characteristics selectively. Flight test data, used as comparison criteria in certification, should be acquired in package during aircraft development or overseas acquisition. The establishment of certification system is expected to improve external credibility and improve competitiveness in overseas market.

Automatic Multi-coupler Performance Evaluation for the PMC Rolling Stock (PMC 차량용 자동복합연결기 성능평가)

  • 이찬우;허현무
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.368-375
    • /
    • 1999
  • This paper describes the evaluation methods and criteria used verify field performance of automatic multi-coupler for the PMC rolling stock. Automatic multi-coupler was designed and manufactured by KRRI , Woojin electric machinery CO., and Yujinchajeon MFG.CO., LTD in 1999. Through field performance test of PMC rolling stock, vibration, brake system, assembly and disassembly of complex train were measured on the condition of service operation. As a result, test results meet the criteria proposed by KNR and KRRI.

  • PDF

Physical model test of Jintan underground gas storage cavern group

  • Chen, Yulong;Wei, Jiong
    • Geomechanics and Engineering
    • /
    • v.30 no.1
    • /
    • pp.45-49
    • /
    • 2022
  • In the present study, a physical model was built for the Jintan underground gas storage cavern group according to the similarity theory. In this regard, four ellipsoid caverns were built with scaled in-situ stresses and internal pressure. Then the stability of underground caverns was analyzed. The obtained results demonstrate that loss of internal pressure adversely affects the safety of caverns and attention should be paid during the operation of gas storage.

Design and Operational Test of 22.9kV, 30m, 3phase HTS Cable Cooling System

  • Kim Do-Hyung;Kim Choon-Dong;Park In-Son;Jang Hyun-Man;Lee Su-Kil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.46-49
    • /
    • 2006
  • The 30m, 3phase, 22.9kV HTS (High Temperature Superconducting) power cable system was produced by LS Cable Ltd. The project aims for a commercial HTS cable. The designing, the manufacturing and the initial operating of HTS cable system were completed by 2004. Then, we have performed a long term operational test since February, 2005. This paper mainly reports the result of the HTS cable cooling operation.

Development of Delay Test Architecture for Counter (카운터 회로에 대한 지연결함 검출구조의 개발)

  • 이창희;장영식
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.1
    • /
    • pp.28-37
    • /
    • 1999
  • In this paper. we developed a delay test architecture and test procedure for clocked 5-bit asynchronous counter circuit based on boundary scan architecture. To develope, we analyze the problems of conventional method on delay test for clocked sequential circuit in boundary scan architecture. This paper discusses several problems of delay test on boundary scan architecture for clocked sequential circuit. Conventional test method has some problems of improper capture timing, of same pattern insertion, of increase of test time. We suggest a delay test architecture and test procedure, is based on a clock count-generation technique to generate continuous clocks for clocked input of CUT. The simulation results or 5-bit counter shows the accurate operation and effectiveness of the proposed delay test architecture and procedure.

  • PDF

A Study on the Evaluation Method for optimal Tensile NOL Ring Composite Specimen Manufactured by Filament Winding Process-to manufacture and elvaluate the composite turbine blade of wind generator system- (필라멘트 와인딩 공법으로 제조된 복합재료 NOL Ring 시험편의 최적 인장강도의 평가법에 관한 연구 -풍력발전용 복합재료 터빈블레이드 제조 및 평가를 목적으로-)

  • 배창원;권순철;임철문;엄수현;김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.87-94
    • /
    • 2001
  • Filament winding process is a comparatively simple operation in which continuous reinforcements in the form of roving are wound over a rotating mandrel. And now it is well established as a versatile method for storage tanks and pipe for the chemical and other industries. In this study, tensile strength of a filament wound ring specimens were evaluated by split disk test fixture and dress disk test fixture. The results obtained from experiments were compared with the theoretical values obtained by the rule of mixture. And the purpose of this paper is to suggest an appropriate test method for the evaluation of tensile properties of filament wound structures. The tensile strength of a ring specimens tested by the dress disk test showed better agreement with the theoretical values than of a ring specimen tested by the split disk test because the stress concentration in edges of s split disk test fixture is more severe than the that of dress disk test fixture. The results showed that the tensile strength of a ring specimen was influenced by the geometry of test fixture, the continuity of fibers, fiber-tension, fiber-end and stress concentration in specimen.

  • PDF

Ground Vibration Test for Korea Sounding Rocket - II PFM (과학로켓 2호(KSR-II) 준비행 모델의 지상 진동 시험)

  • 우성현;김홍배;문상무;이상설;문남진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.546-551
    • /
    • 2001
  • Space Test Department at KARI(Korea Aerospace Research Institute) plans to carry out the GVT(Ground Vibration Test) for the KSR(Korea Sounding Rocket)-III FM(Flight Model) which is being developed by Space Technology R&D Division. KSR-III will be an intermediate to the launch vehicle capable of carrying satellites to their orbits. GVT offers very important information to predict the behavior of KSR in its operation, and to develop the flight control and aerodynamic analysis. For development of test facilities, testing and analysis methods which can be used for the future test, Space Test Department has performed the GVT with KSR-II PFM(Proto-Flight Model) at Satellite Integration & Test Center of KARl This paper discusses the procedures, techniques and the results of it. In this test, to simulate free-free condition, test object hung in the air by 4 bungee cords specially devised. The GVT was carried out using pure random excitation technique with MIMO(Multi-Input-Multi-Output) method with three electromagnetic shakers, and poly-reference parameter estimation was used to identify the modal parameters. As the result of the test, 11 mode shapes and modal parameters below 200㎐ were identified and compared with analytical results.

  • PDF

Large Eddy Simulation of Turbulent Channel Flow Through Estimation of Test Filter Width (Test Filter 너비의 추정을 통한 난류 채널 유동의 Large Eddy Simulation)

  • Choi, Ho-Jong;Lee, Sang-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.853-858
    • /
    • 2003
  • The suitable estimation of the filter width in the dynamic eddy viscosity model were investigated in high Reynolds number channel flow. In this study, the improvement on matters by optimizing the test filter shape was attempted through the numerical experiment. The way that select optimum test filter width is recommended. Some test filters, one is based on a discrete representation of the top-hat filter and another are based on a high-order filtering operation, are evaluated in simulations of the turbulent channel flow at Reynolds number 1020, based on friction velocity and channel half width. It appears that the estimation of test filter width practically can decrease the dissipative nature of dynamic eddy viscosity model with explicit test filter. It shows that the value of the filter width ratio used in the dynamic procedure must match the properties of the test filter actually used in the calculation.