• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.039 seconds

Design and Implementation of the Efficient Potted Plants Management System based on Home Network (홈 네트워크 기반의 효율적인 화분관리시스템 설계 및 구현)

  • Kwon, Soon-Ryang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1904-1910
    • /
    • 2011
  • At most of the home or office, we have planted ornamental plants raised in pots, but it is difficult to follow because of busy life and lack of expertise in plants management. In this paper, we intend to design and implement a home network-based potted plants management system to solve the difficulty of plants management. To attain this end, firstly, we designed the structure of the plants management system, information flows and operation control flows. Secondly, we implemented the system based on designed results. Finally, we verified the implemented system through the functionality test for 10 items. In the results, it is expected that we can manage the potted plants efficiently than existing ornamental plant management systems and home network systems focusing appliances.

Designing and Developing an Automatic Robot System for the Itemized Loading of Apple Boxes at the Agriculture Products Processing Center (거점산지유통센터의 사과박스 구분적재 자동화 로봇 시스템 설계 및 구현)

  • Kim, Myung-Sic;Kim, Kyu-Ik;Ryu, Keun Ho
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.11
    • /
    • pp.689-698
    • /
    • 2015
  • Currently, the itemized box loading operation at the Agriculture Products Processing Center which distributes agricultural products for the region is carried out manually. The process of loading agricultural products requires great manpower and had been resolved through the part-time employment of the residents of farm villages. However, recently it has become quite difficult to secure manpower as the aging within the rural community has been intensified. Hence, the necessity for countermeasures such as facility automation or use of robots have become necessary. This study suggests an automatic robot system for the itemized loading of apple boxes at the Agriculture Products Processing Center. The suggested method is to design and develop equipment such as a conveyer, robot, and bar code reader. In addition, a sorting plan, operational control, generation of control information, and software module that could monitor the inside of the Agriculture Products Processing Center is needed. After test-operating and evaluating the developed system, the existing manual work would be replaced with the automated robot system in order to enhance work efficiency and resolve safety issues.

Development of Statistical/Probabilistic-Based Adaptive Thresholding Algorithm for Monitoring the Safety of the Structure (구조물의 안전성 모니터링을 위한 통계/확률기반 적응형 임계치 설정 알고리즘 개발)

  • Kim, Tae-Heon;Park, Ki-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • Recently, buildings tend to be large size, complex shape and functional. As the size of buildings is becoming massive, the need for structural health monitoring(SHM) technique is ever-increasing. Various SHM techniques have been studied for buildings which have different dynamic characteristics and are influenced by various external loads. Generally, the visual inspection and non-destructive test for an accessible point of structures are performed by experts. But nowadays, the system is required which is online measurement and detect risk elements automatically without blind spots on structures. In this study, in order to consider the response of non-linear structures, proposed a signal feature extraction and the adaptive threshold setting algorithm utilized to determine the abnormal behavior by using statistical methods such as control chart, root mean square deviation, generalized extremely distribution. And the performance of that was validated by using the acceleration response of structures during earthquakes measuring system of forced vibration tests and actual operation.

Compensating algorithm for a measurement type CT considering hysteresis characteristic of the core (히스테리시스 특성을 고려한 측정용 변류기 보상 알고리즘)

  • Kang, Yong-Cheol;Zheng, Taiying;Lee, Byung-Eun;So, Soon-Hong;Lee, Hyun-Woong;Lee, Mi-Sun;Park, Jung-Ho;Choi, Hyun-Tae;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.44-45
    • /
    • 2007
  • This paper deals with error compensation in current transformers. Since the exciting current can be considered as the main error source, its evaluation can allow the compensation of its detrimental effects to be obtained. The exciting current required by the transformer in every king of steady state operation can be determined by simply acquiring the secondary current, provided that the examined CT has been preliminarily identified. This paper also proposed a new approach to the model of the exciting branch. The exciting branch can be divided into a non-linear core loss resistor, and a non-linear magnetizing inductor whose flux and current characteristic is not the same as the characteristic shown by the joined tips of the first quadrant of a family of hysteresis loops. The performance of the proposed algorithm was validated under various conditions using EMTP generated data. Test result show, in all cases an improvement in primary current reproduction accuracy, compared with that achieved using CT's ratio.

  • PDF

The Implementation on the Traffic Signal Control Equipment of Intelligence Type Using the PLC (PLC를 사용한 지능형 교통 신호 제어 설비 구현)

  • 김태성;위성동
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.1
    • /
    • pp.74-81
    • /
    • 1998
  • It is not good joint that today's traffic control system that the course of traffic volume increase tendency is followed, in the traffic volume is approched into the time of my car. Accordingly when we analyzed the existing traffic signal control system, the traffic signal system is developed from the machine type that the motor was centered, to get up to date, to the intelligence electron signal control system. But yet, when we have a test and a A/S on the control circuit, the circuit that is designed to the center IC and ROM are complicated. Also, the time of pass lamp that the car line stream is going, can not extended automatically a time till the traffic volume is decreased to the same direction. This theme must be a real time intelligence control system that the time of pass lamp can extend aumatically. The circuit of sequence ladder diagram on the traffic signal control of a crossroads that is desinged, can be satisfied the complicated vehicle order. Therefore when the circuit is changed, the new developed system is economical with that dosen't needs any of components to require the circuit equipment, and the time is saved with needlessness of the circuit wiring again, and have a much trustworthy. The control method of pass signal lamp in the car line stream connecting among PLC and Relay and Temp Sensor, can be changed to hand operation and to semi-automation and to all-automation. New intelligence traffic signal system is composed with all-together system of T Sensor + Video Camera + IBM PC that is able to guiding the establishment of traffic order.

  • PDF

Analysis of Irrigation Efficiency and Pattern in Galshin Pumping District (갈신양수장 관개지구의 관개효율과 관개패턴분석)

  • Ryu, Bumhee;Park, Seungki
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.3
    • /
    • pp.91-102
    • /
    • 2020
  • The purpose of study was analyze the pumping characteristics, Irrigation Efficiency(IE), and irrigation pattern by period of rice growing stage with based on the performance of design irrigation water requirement and operational Galshin Pumping(GP) station in GP irrigation district constructed under rural water development project master plan. GP station was located in Yedang reservoir, Yesan-gun, Chungcheongnam-do and has been supplying irrigation water since 2006. The research data are the Irrigation Water Requirement(IWR) and the Pumping Water Amount(PWA) from 2006 to 2015 at the GP station, which is the supplied amount. The IWR were calculated using the Blaney-Criddle formula of the HOMWRS program, Hydrological Operation Model for Water Resource System, developed by Korea Rural Community Corporation. The Blaney-Criddle formula was used to calculate design irrigation water requirement of Galshin rural water development project master plan. During 2006-2015, the study period, the annual average IWR is 763.2(±149.1)mm, the annual PWA of the GP station is 397.4mm to 1,056.9mm, and those average annual PWA is 643.4(±208.4)mm. The annual IE of GP station 96.5% to 169.0%, and the average annual IE is 124.3%, which is higher than the research results conducted in other pumping stations. Analyzing the irrigation patterns of the GP irrigation district, the IWR Ratio per 10days(IWRR) and the PWA Ratio per 10days(PWAR) of the G P station were obtained. The IWRR is the percentage of IWR for each 10 days of a month to total IWR per year, and the PWAR is the percentage of PWA for each 10 days of a month to total PWA per year. The Kolmogorov- Smirnov(K-S) test results of IWRR and PWAR showed the characteristics classification by rice growing stage and stable normal distribution characteristics. Average IWRR(AIWRR) and Average PWAR(APWAR) are presented as irrigation patterns. Irrigation pattern analysis will be able to standardize comparison, analysis and probability calculation of the pumping station characteristics of different pumping stations and apply to objective evaluation of the pumping station district.

Image Noise Reduction Filter Based on Robust Regression Model (로버스트 회귀모형에 근거한 영상 잡음 제거 필터)

  • Kim, Yeong-Hwa;Park, Youngho
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.5
    • /
    • pp.991-1001
    • /
    • 2015
  • Digital images acquired by digital devices are used in many fields. Applying statistical methods to the processing of images will increase speed and efficiency. Methods to remove noise and image quality have been researched as a basic operation of image processing. This paper proposes a novel reduction method that considers the direction and magnitude of the edge to remove image noise effectively using statistical methods. The proposed method estimates the brightness of pixels relative to pixels in the same direction based on a robust regression model. An estimate of pixel brightness is obtained by weighting the magnitude of the edge that improves the performance of the average filter. As a result of the simulation study, the proposed method retains pixels that are well-characterized and confirms that noise reduction performance is improved over conventional methods.

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng;Yan, Changqi;Meng, Zhaoming;Chen, Kailun;Song, Shaochuang;Yang, Zonghao;Yu, Jie
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1321-1329
    • /
    • 2016
  • To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

The Treatment of Gynecomastia using Ultrasound-Assisted Liposuction with Pull-Out Method or Excision through Periareolar Incision (다양한 술식을 이용한 여성형 유방증의 치료: 초음파 지방흡입술과 풀아웃법 또는 유륜절개를 통한 절제술)

  • Sim, Hyung Bo;Yoon, Sang Yub
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.237-242
    • /
    • 2007
  • Purpose: Gynecomastia is an abnormal increase in the volume of the male breast. Patients affected by gynecomastia with significant glandular enlargement may respond to suction alone and/or sharp dissection and excision. The purpose of this report is to introduce the indications and results of authors' two techniques. Methods: The diameter of parenchyme was determined by a pinch test after liposuction. For the parenchymal diameter less than 4 cm, ultrasound-assisted liposuction was performed, in conjunction with the "pull-out technique" to effectively remove the fibrofatty tissue of the male breast through a single 5-7 mm incision. For the parenchymal diameter more than 4 cm, ultrasound-assisted liposuction and excision were applied through 2.5 cm periareolar approach. Results: A total of 94 patients (185 breasts) underwent the operation from October 2000 to October 2003 and mean follow-up period was 12 months. The volume of aspirates ranged from 50 to 450 cc per breast. There were no major complications such as skin flap necrosis. Five reoperations were performed for 1 hypertrophic scar, 2 under-resected and 2 hematoma cases. The patient's satisfaction was high and most of them were pleased with the shape of the breasts and scars. Conclusion: These procedures can minimize scars and reduce the incidence of contour problem such as saucer deformity, and provides consistent results. Patients can return to full activities in 48 hours. It can be offered as an option for the treatment of gynecomastia.

Risk Factors of Tissue-Expander Infection in Breast Reconstruction (유방재건술에서 조직확장기 감염의 위험인자)

  • Han, Sung-Bum;Lee, Dong-Won;Lew, Dae-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.621-626
    • /
    • 2011
  • Purpose: Implant-based breast reconstruction has multiple advantages such as decreased morbidity, shorter operative time and faster recovery. However, postoperative infection with tissue expander increases medical cost and causes a delay in concurrent antineoplastic treatment. To reduce tissue expander infection, it is important to identify related risk factors and minimize them when possible. Methods: A retrospective review of patient records in a single breast cancer center was performed. Eighty-six tissue expanders were placed in 80 women for postmastectomy breast reconstruction. Variables including patients'age, body mass index (BMI), preoperative breast volume, operation time, drain indwelling time, postoperative seroma/hematoma formation, chemotherapy, and radiation therapy were evaluated. Infection was defined as the status that shows any symptom of local inflammation and identification of pathogens. Representative values were compared through Student's t-test and univariate and multivariate analyses. Results: We examined 86 postmastectomy tissueexpanders which were placed between June 2004 and April 2010. Seven cases of tissue expander infection (8.1%) were identified. The infected tissue expander was removed in three of the cases. The relationship between BMI, and preoperative breast volume and that between infection and non-infection groups were significant ($p$ <0.05). Univariate analysis showed significant association between BMI ($p$=0.023) and preoperative breast volume ($p$=0.037). Multivariate analysis revealed that BMI and preoperative breast volume were independent variables regarding tissue expander infection. Conclusion: Certain characteristics of implant-based breast reconstruction patients increase infection rate of tissue expander. These risk factors should be monitored and evaluated before surgeries for more successful outcome.