• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.037 seconds

Design of CFL Linearisation Chip for the Mobile Radio Using Ultra-Narrowband Digital Modulation (디지털 초협대역 단말기용 CFL 선형화 칩 설계)

  • Chong Young-Jun;Kang Min-Soo;Yoo Sung-Jin;Chung Tae-Jin;Oh Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.671-680
    • /
    • 2005
  • The CFL linearisation chip which is one of key devices in ultra-narrowband mobile radio transmitter using CQPSK digital modulation method is designed and implemented with $0.35{\mu}m$ CMOS technology. The reduced size and low cost of transmitter are available by the use of direct-conversion and CFL ASIC chip, which improve the power effi챠ency and linearity of transmitting path. In addition, low power operation is possible through CMOS technology The performance test results of transmitter show -25 dBc improvement of IMD level at the 3 kHz frequency offset and then satisfy FCC 47 CFR 90.210 E emission mask in the operation of CFL ASIC chip. At that time, the transmitting power is about PEP(Peak-to-Envelope Power) 5 W. The main parameters to improve the transmitting characteristic and to compensate the distortion in feed back loop such as DC-offset, loop gain and phase value are interfaced with notebook PC to be controlled with S/W.

The correlation of bone probing, radiographic and histometric measurements (골탐침과 방사선학적 및 조직학적 계측의 상관관계)

  • Hwang, Sung-Joon;Kim, Chang-Sung;Lee, Doug-Youn;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.4
    • /
    • pp.615-624
    • /
    • 2003
  • The most accurate method to assess bone level is the histometric measurement. However it causes discomfort in patients and damage to the regenerated tissues. in the present study, we used 4 type regenerative therapies, The present study evaluated the clinical reliability and accuracy of bone probing measurements and radiographic bone level in the assessment of bone level by comparing those results with histometric confirmed bone level. Twentyfour(24) intrabony defects(4${\times}$4mm 1-wall intrabony defects) were surgically created in the mandibular second and fourth premolars of 6 beagle dogs. The control group underwent a conventional flap operation. Experimental group I was treated with calcium phosphate glass only, and while experimental group 2 was treated with GTR and experimental group 3 was treated with calcium phosphate glass and GTR. The subjects were sacrificed 8 weeks after the operation and a bone probing measurements, radiographic measurement and histometric measurement was performed. The correlation between bone probing measurements(BP) and histometric measurement(HL), and radiographic measurement(RL) and histometric measurement(HL) were analyzed with Spearman's rank correlation analysis and the statistical significance with respect to the type of regenerative therapies was analyzed with the Kruskal Wallis test. The coefficient of correlation to HL was 0.73 for RL and 0.90 for BP. The type of regenerative therapies had no significant effect on the difference between HL and other measurements. The results of this study suggests that bone probing measurements most closely represents actual bone level. So bone probing measurements may be a good clinical method for assessing the hone level following any type of periodontal regenerative therapies.

A Study on Strengthening Consequence Management System Against CBRN Threats (CBRN 위협에 대비한 사후관리체계 강화방안)

  • Kwon, Hyuckshin;Kwak, Minsu;Kim, Kwanheon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.429-435
    • /
    • 2020
  • North Korea declared itself complete with nuclear force after its sixth nuclear test in 2017. Despite efforts at home and abroad to denuclearize the Korean Peninsula, the prospects for the denuclearization are not bright. Along with political and diplomatic efforts to deter NK's WMD threats, the government is required to strengthen its consequence management capabilities against 'catastrophic situations' expected in case of emergency. Accordingly, this study was conducted to present measures to strengthen follow-up management against CBRN threats. The research model was partially supplemented and utilized by the THIRA process adopted and utilized by the U.S. Department of Homeland Security among national-level disaster management plan development models. Korea's consequence management (CM) system encompasses risk and crisis management on disaster condition. The system has been carried out in the form of a civil, government and military integrated defense operations for the purpose of curbing the spread or use of CBRNs, responding to threats, and minimizing expected damages. The preventive stage call for the incorporation of CBRN concept and CM procedures into the national management system, supplementing the integrated alarm systems, preparation of evacuation facilities, and establishment of the integrated training systems. In the preparation phase, readjustment of relevant laws and manuals, maintenance of government organizations, developing performance procedures, establishing the on-site support systems, and regular training are essential. In the response phase, normal operations of the medical support system for first aid and relief, installation and operation of facilities for decontamination, and development of regional damage assessment and control guidelines are important. In the recovery phase, development of stabilization evaluation criteria and procedures, securing and operation of resources needed for damage recovery, and strengthening of regional damage recovery capabilities linked to local defense forces, reserve forces and civil defense committees are required.

A Study on the Curriculum of University Calculus Reflecting the 2015 Revised Curriculum (2015 개정 교육과정을 반영한 대학 미적분학 교과에 대한 탐색)

  • Kim, Yun Ah;Kim, Kyung Mi
    • Communications of Mathematical Education
    • /
    • v.31 no.3
    • /
    • pp.349-366
    • /
    • 2017
  • The 2015 revised curriculum is an integrated curriculum that reflects national and societal needs to foster creative convergent talent in the school curriculum. Along with these changes, the Ministry of Education introduced a system to change the major from 2017 to the fourth year of university. Therefore, each university should prepare to reflect the curriculum and institutional change before welcoming students who have completed the 2015 revised curriculum. The university needs to study the countermeasures for implementing the 2015 revised curriculum and expanding the period of major change when preparing the curriculum and contents of the calculus courses that freshmen take. Handong University has been studying the operation methods of new students who want to decide their major at the first grade, such as operating calculus courses at various levels and allocating appropriate proportions of calculus for preliminary examinations. This case is similar to the basic purpose of the revised curriculum in 2015, so it can suggest implications for the operation of the university calculus class after the curriculum revision. In this paper, we have analyzed the results of the recent freshman mathematics test for the recent 5 years and the students' calculus grades and compared them with the contents of the calculus curriculum operated by Handong University and the 2015 revised higher mathematics curriculum. As a result, we proposed five classes of calculus suitable for college major and it was found that the calculus curriculum should include the missing quadratic method in the 2015 revised curriculum.

Reduction of Hexavalent Chromium on PVC Filters (혜산산업보건학술상 수상논문 - PVC 여과지에 채취된 6가 크롬의 환원)

  • Sin, Yong-Cheol
    • 월간산업보건
    • /
    • s.356
    • /
    • pp.16-25
    • /
    • 2017
  • Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidationreduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 ; 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 ; 89.9) at 1 hour and 81.0% (78.3 ; 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 ; 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  • PDF

Development of a System to Measure Quality of Cut Flowers of Rose and Chrysanthemum Using Machine Vision (기계시각을 이용한 장미와 국화 절화의 품질 계측장치 개발)

  • 서상룡;최승묵;조남홍;박종률
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.231-238
    • /
    • 2003
  • Rose and chrysanthemum are the most popular flowers in Korean floriculture. Sorting flowers is a labor intensive operation in cultivation of the cut flowers and needed to be mechanized. Machine vision is one of the promising solutions for this purpose. This study was carried out to develop hardware and software of a cut flower sorting system using machine vision and to test its performance. Results of this study were summarized as following; 1. Length of the cut flower measured by the machine vision system showed a good correlation with actual length of the flower at a level of the coefficients of determination (R$^2$) of 0.9948 and 0.9993 for rose and chrysanthemum respectively and average measurement errors of the system were about 2% and 1% of the shortest length of the sample flowers. The experimental result showed that the machine vision system could be used successfully to measure length of the cut flowers. 2. Stem diameter of the cut flowers measured by the machine vision system showed a correlation with actual diameter at the coefficients of determination (R$^2$) of 0.8429 and 0.9380 for rose and chrysanthemum respectively and average measurement errors of the system were about 15% and 7.5% of the shortest diameter of the sample flowers which could be a serious source of error in grading operation. It was recommended that the error rate should be considered to set up grading conditions of each class of the cut flowers. 3. Bud maturity of 20 flowers each judged using the machine vision system showed a coincidence with the judgement by inspectors at ranges of 80%∼85% and 85%∼90% for rose and chrysanthemum respectively. Performance of the machine vision system to judge bud maturity could be improved through setting up more precise criteria to judge the maturity with more samples of the flowers. 4. Quality of flower judged by stem curvature using the machine vision system showed a coincidence with the judgement by inspectors at 90% for good and 85% for bad flowers of both rose and chrysanthemum. The levels of coincidence was considered as that the machine vision system used was an acceptable system to judge the quality of flower by stem curvature.

Applicability test of broad leaf samples stored at the NESB for biomonitoring of airborne pollutants (국가환경시료은행 활엽 시료를 활용한 지역별 대기침적 오염물질 모니터링 활용성 검토)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Jang, Heeyon
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.6
    • /
    • pp.532-541
    • /
    • 2016
  • The National Environmental Specimen Bank (NESB) has been collecting broad leave samples to monitor environmental pollution from five different designated sampling areas. In order to ensure the reproducibility and comparability of the results, all the procedures from selecting trees and pooling leaves to make the representative sample are defined in the standard operation procedures(the SOP). The representative samples were subjected to the chemical analyses for some heavy minerals and Polycyclic Aromatic Hydrocarbons(PAHs). The uncertainty levels involved in each step of the SOP, that is, the sampling and the chemical analysis, were derived using the Robust ANOVA, which enables the relative comparison among the different levels of pollutants concentrations with confidence. Furthermore, the effect of the varying degrees of precipitation on the pollutants concentration of the leaves was also examined. Overall, the biological difference estimated from the duplicate samples was found to exceed the variation across the site, implying even aerial deposition over site. Samples from Gwanak Mt. showed highest heavy metal concentrations than the other sites. Washing off effect of the pollutants adhering in the form of particles on the leaf surface was found to be affected by the cumulative precipitation.

A Study of Big data-based Machine Learning Techniques for Wheel and Bearing Fault Diagnosis (차륜 및 차축베어링 고장진단을 위한 빅데이터 기반 머신러닝 기법 연구)

  • Jung, Hoon;Park, Moonsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.75-84
    • /
    • 2018
  • Increasing the operation rate of components and stabilizing the operation through timely management of the core parts are crucial for improving the efficiency of the railroad maintenance industry. The demand for diagnosis technology to assess the condition of rolling stock components, which employs history management and automated big data analysis, has increased to satisfy both aspects of increasing reliability and reducing the maintenance cost of the core components to cope with the trend of rapid maintenance. This study developed a big data platform-based system to manage the rolling stock component condition to acquire, process, and analyze the big data generated at onboard and wayside devices of railroad cars in real time. The system can monitor the conditions of the railroad car component and system resources in real time. The study also proposed a machine learning technique that enabled the distributed and parallel processing of the acquired big data and automatic component fault diagnosis. The test, which used the virtual instance generation system of the Amazon Web Service, proved that the algorithm applying the distributed and parallel technology decreased the runtime and confirmed the fault diagnosis model utilizing the random forest machine learning for predicting the condition of the bearing and wheel parts with 83% accuracy.

Clinical Roles of Continuous Lumbar Drainage in Acute Hydrocephalus Patients (급성 수두증 환자에서 지속적 요추지주막하 배액의 임상적 역할)

  • Yang, Geun Jin;Kim, Mun Chul;Chung, Hoon;Lee, Sang Pyung;Choi, Gi Whan;Yeo, Hyung Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.644-649
    • /
    • 2000
  • Objective : Acute hydrocephalus can be caused by many pathologic conditions such as sub- arachnoid hemorrhage, intraventricular hemorrhage, inflammatory diseases. External ventricular drainage(EVD) through trephination of the skull is essential procedure for progressing or persistent symptomatic acute hydrocephalus. If the EVD can not be removed in short period, the chance of ventriculitis increases and periodic transposition of the draining catheter should be considered. Shunt procedure can not be performed in acute hemorrhage or infectious condition because of the risk of shunt malfunction or intra-abdominal spreading of the infection, respectively. The authors replaced EVD with continuous lumbar drainage(CLD) for the purpose of controlling acute hydrocephalus and preventing ventriculitis simultaneously, or treating ventriculitis more effectively in case of infection which had already broken out. CLD has many advantages over EVD, although, it can complicate disastrous downward brain herniation in patients with elevated intracranial pressure. The authors performed CLD with EVD maintained and then tested the possibility of the brain herniation with quite simple method. If the CLD was proven as safe through the test, EVD could be replaced with it without terrible herniation. Material and Method : Between September 1998 and April 1999, 10 patients underwent CLD in replacement of EVD. Among them, 5 were patients with aneurysmal subarachnoid hemorrhage, 2 were patients with thalamic hematoma and intraventricular hemorhage and 3 were patients with traumatic intracranial hemorrhage. Results : In eight of them the replacements were successfully done and one of them died on account of medical illness. In two of them the replacement could not be performed because of the risk of herniation and all expired owing to ventriculitis. Two patients required permanent shunt operation. Conclusion : This article provides a valuable alternative method of treatment for persistent symptomatic hydrocephalus which can not be managed with shunt operation immediately.

  • PDF

DEVELOPMENT OF CCD IMAGING SYSTEM USING THERMOELECTRIC COOLING METHOD (열전 냉각방식을 이용한 극미광 영상장비 개발)

  • Park, Young-Sik;Lee, Chung-Woo;Jin, Ho;Han, Won-Yong;Nam, Uk-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E(768$\times$512 pixels) CCD chip, thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of $-25^{\circ}C$. We employed an Uniblitz VS25s shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO) ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of $-10^{\circ}C$, a linearity 99.9$\pm$0.1%, gain 4.24e-/adu, and system noise is 25.3e-(rms). For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry($\pm$0.01mag) even though the CCD is not at 'conventional' cryogenic temperatures(140k). The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  • PDF