• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.036 seconds

Design, Implementation, and Validation of KOMPSAT-2 Software Simulator

  • Lee, Sang-Uk;Lee, Byoung-Sun;Kim, Jae-Hoon;Cho, Sung-Ki
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.140-152
    • /
    • 2005
  • In this paper, we present design features, implementation, and validation of a satellite simulator subsystem for the Korea Multi-Purpose Satellite-2 (KOMPSAT-2). The satellite simulator subsystem is implemented on a personal computer to minimize costs and trouble on embedding onboard flight software into the simulator. An object-oriented design methodology is employed to maximize software reusability. Also, instead of a high-cost commercial database, XML is used for the manipulation of spacecraft characteristics data, telecommand, telemetry, and simulation data. The KOMPSAT-2 satellite simulator subsystem is validated by various simulations for autonomous onboard launch and early orbit phase operations, anomaly operation, and science fine mode operation. It is also officially verified by successfully passing various tests such as the satellite simulator subsystem test, mission control element system integration test, interface test, site installation test, and acceptance test.

  • PDF

The study for function and operation of the excitation equipment for short circuit generator (단락발전기 용 여자장치의 조작과 기능에 대한 고찰)

  • Kim, Sun-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.735-736
    • /
    • 2008
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, CLR, Back Up Breaker, Making Switch and Excitation Equipment etc. Gradually an allowable tolerance of the short circuit test voltage is become smaller by the standards for short circuit test. The excitation equipment of short circuit generator is very important for test voltage is adjusted by the excitation equipment. Especially the excitation equipment must be possessed character of exactitude, durability and inalterability because some times around 10,000 times opening and closing short circuit test is requested by clint, which must be done within one minute. The purpose of this study for function and operation of the excitation equipment which rated DC voltage is 1,000V, rated DC current is 300A, rated out put is 30kW and type is YNEX 97S-441/609, is to help operation of short circuit generator.

  • PDF

Analysis of Engine Operation Condition by Using Coastdown Test under Gear Engaged Condition (기어 물림 상태의 타행 주행 저항을 이용한 엔진 운전 조건의 분석)

  • Shim, Beom-Joo;Park, Kyoung-Suk;Park, Jun-Su;Min, Byeong-Du
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.6
    • /
    • pp.61-66
    • /
    • 2012
  • Conventional method to transform vehicle driving condition to engine operation mode is to use vehicle road load under neutral gear and mechanical efficiency of drivetrain. But this method requires additional measurement of efficiency of drivetrain on a test rig. And this measurement is normally done at fixed speed and thus estimated accuracy of engine operation mode is not considered to be high enough. This study suggests new method to calculate engine operation mode for prescribed driving mode such as NEDC using vehicle coastdown test under gear engaged condition without measurement of mechanical efficiency of drivetrain. Coastdown test was done under neutral and gear engaged condition for comparison and also trial to extract mechanical loss of drivetrain was carried out. Calculated engine torque by conventional and newly suggested method was compared with actually measured torque of a vehicle on a chassis dynamometer during NEDC. Newly suggested method showed slightly higher accuracy of accumulated brake work during NEDC.

Development of Process Model for Turbine Control Valve Test in a Power Plant (발전소 터빈제어 밸브시험 계통 모델 개발)

  • Woo, Joo-Hee;Choi, In-Kyu;Park, Doo-Yong;Kim, Jong-An
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.830-837
    • /
    • 2011
  • A turbine control system which has been operated for years in a nuclear power plant was retrofitted with a newly developed digital control system. After completion of the retrofit, turbine valve tests were performed to ensure the integrity of each valve's control function. The sequence of each valve test is composed of a closing process and a reopening process. To minimize megawatt variation which normally occurs during the test sequence, we employed a kind of compensator algorithm in the new digital control system which also have been used in the old system. There were difficulties finding optimal parameter settings for our new compensator algorithm because the power plant didn't allow us to perform necessary tuning procedures while the turbine is on load operation. Therefore an alternative measure for the compensator tuning which is independent of the turbine actual operation had to be implemented. So, a process model for the test was required to overcome this situation. We analyzed the operation data of the test and implemented the process model by use of input and output variable relations. Also we verified the process model by use of another condition's operating data. The result shows that the output of model is similar to the actual operation data.

An Aerodynamic and Acoustic Study of Nasalization in Cleft Palate Speakers. (구개열 언어의 비음화에 관한 공기역학 및 음향학적 연구)

  • Lee, Jong-Han;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.105-119
    • /
    • 1999
  • Cleft palate patients have general speech problems with resonance disorders and articulation disorders. The aim of this study is to find the aerodynamic and acoustic characteristics of the nasalization in cleft palate speakers. Thirteen control groups and three cleft palate patients pre- and post operation were selected for these studies. The test words are composed by polysyllabic words: consonants between high vowel /i/ analysis. The cleft palate patients repeated test words pre- and post-operation from one, three and six month periods. The subjects repeated test words on Macquirer and on Nasometer Model 6200-3. The aerodynamic and acoustic results of nasalization show as follows: (1) The nasal rate in overall airflow of aspirated consonant for cleft palate patients shows higher levels than that of the control group. It had decreased since one month after operation. (2) The overall airflow of cleft palate patients is higher than in the control group, however oral air pressure is lower than control group. (3) The nasal airflow and the nasal rate in overall airflow of cleft palate patients has higher than the control group, however its decreased after operation. (4) The nasalance scores of cleft palate patients were 40% higher than that of the control group. The scores did not decrease after operation. The nasalance score of lateral and fricative sounds did not decrease after operation.

  • PDF

Design on the efficient BILBO for BIST allocation of ASIC (ASIC의 BIST 할당을 위한 효과적인 BILBO 설계)

  • 이강현
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.9
    • /
    • pp.53-60
    • /
    • 1997
  • In this paper, an efficient BILBO(named EBILBO) is proposed for batch testing application when a BIST (built-in self test) circuit is implemented on ASIC. In a large and complex circuit, the proposed algorithm of batch testing has one pin-count that can easily control 4 test modes in the normal speed of circuit operation. For the implementation of the BIST cifcuit, the test patern needed is generated by PRTPG(pseudo-random test pattern generator) and the ouput is observed by proposed algorithm is easily modified, such as the modelling of test pattern genration, signature EBILBO area and performance of the implemented BIST are evaluated using ISCAS89 benchmark circuits. As a resutl, in a circuit above 600 gates, it is confirmed that test patterns are genrated flexibly about 500K as EBILBO area is 59%, and the range of fault coverage is from 88.3% to 100%. And the optimized operation frequency of EBILBO designed and the area are 50MHz and 150K respectively. On the BIST circit of the proposed batch testing, the test mode of EBILBO is able to execute as realtime that has te number of s$\^$+/n$\^$+/(2s/2p-1) clocks simultaneously with the normal mode of circuit operation. Also the proposed algorithm is made of the library with VHDL coding thus, it will be widely applied to DFT (design for testability) that satisfies the design and test field.

  • PDF

Development of selectable observation point test architecture in the Boundry Scan (경계면스캔에서의 선택가능한 관측점 시험구조의 개발)

  • Lee, Chang-Hee;Jhang, Young-Sig
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.87-95
    • /
    • 2008
  • In this paper, we developed a selectable observation Point test architecture and test procedure for clocked 4-bit synchronous counter circuit based on boundary scan architecture. To develope, we analyze the operation of Sample/Preload instruction on boundary scan architecture. The Sample/Preload instruction make Possible to snapshot of outputs of CUT(circuit under test) at the specific time. But the changes of output of CUT during normal operation are not possible to observe using Sample/Preload in typical scan architecture. We suggested a selectable observation point test architecture that allows to select output of CUT and to observe of the changes of selected output of CUT during normal operation. The suggested a selectable observation point test architecture and test procedure is simulated by Altera Max 10.0. The simulation results of 4-bit counter shows the accurate operation and effectiveness of the proposed test architecture and procedure.

  • PDF

Convergence study on Effects of Music Therapy in Patients Undergoing Prostatectomy with Spinal Anesthesia (척추마취 전립선절제술환자의 음악요법효과에 대한 융합연구)

  • Lee, Young-Eun;Kim, Ju-Sung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.97-106
    • /
    • 2017
  • The purpose of this convergence study was to identify the effects of favorite music therapy on anxiety, fatigue, and vital signs of patients undergoing prostatectomy with spinal anesthesia. This study used a nonequivalent control group design. A sample of 45 patients was included. The experimental group was given music therapy during operation. The data were collected using a structured questionnaire and monitoring at 30 min before operation, at 20 min and 40min undergoing operation, and at arrival recovery room after operation. Data were analyzed using descriptive statistics, ${\chi}^2-test$, Fisher's exact test, t-test, repeated measures ANOVA. The experimental group reported significantly lower anxiety and lower fatigue than the control group(p=.001; p=.020). However there were no significant differences in the systolic blood pressure, diastolic blood pressure and pulse rate between groups(p=.821; p=.473; p=.782). This findings indicate that the tailored favorite music therapy can be an effective nursing intervention for patient undergoing prostatectomy with spinal anesthesia to reduce anxiety and fatigue related to operation.

The evaluation for the operation surface mounters using a dynamic network (동적 네트워크를 이용한 표면실장기 운영 평가)

  • 이달상
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.570-573
    • /
    • 1996
  • The evaluation test for the operation of rotary type surface mounters which consist of the reel axis, the index table and the X-Y table, has been performed by comparing the new method with the old one in only fields. Because the problem seeking for the optimal operation of rotary type surface mounters, is NP complete, it is almost impossible to get the optimal solutions of large problems. This paper deals with a dynamic network modeling, which can reduce the effort, the cost, and the time used for the performance test of rotary type surface mounters.

  • PDF