• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.033 seconds

Study on Coal Combustion Characteristics with 1MWth Test Facility (1MWth 실험연소로를 이용한 석탄의 연소특성 연구)

  • Jang, Gil Hong;Chang, In Gab;Jeong, Seok Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1464-1472
    • /
    • 1999
  • Design and operation of $1MW_{th}$ pulverized coal combustion testing facility are described. Also the influence of air staging on NOx emission and burnout of coal flames was investigated in this facility. The test facility consisted of coal feeding system, firing system and flue gas treatment system. A top-fired externally air staging burner was adopted in order to avoid influence of gravity on the coal particles and for easy maintenance. Distribution of temperature and chemical species concentration of coal flames could be measured in vertical pass of furnace. Main fuel was pulverized (83.4% less than $80{\mu}m$) Australian high bituminous coal. From variety of test conditions, overall excess air ratio was selected at 1.2(20% excess air). Tho study showed that increasing the staged air resulted in lower NOx omission, and it was suggested to be more than 40% of the total combustion air for the substantial NOx reduction. Sufficient burnout was not achievable when NOx emission was less than 500ppm. Also, the amount of core air did not influence tho NOx reduction.

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

Electricity Market Design for the Incorporation of Various Demand-Side Resources in the Jeju Smart Grid Test-bed

  • Park, Man-Guen;Cho, Seong-Bin;Chung, Koo-Hyung;Moon, Kyeong-Seob;Roh, Jae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1851-1863
    • /
    • 2014
  • Many countries are increasing their investments in smart grid technology to enhance energy efficiency, address climate change, and trigger a green energy revolution. In addition to these goals, Korea also seeks to promote national competitiveness, prepare for the growth of the renewable energy industry, and export industrialization through its strategic promotion of the smart grid. Given its inherent representativeness for Korean implementation of the smart grid and its growth potential, Jeju Island was selected by the Korean government as the site for smart grid testing in June 2009. This paper presents a new design for the electricity market and an operational scheme for testing Smart Electricity Services in the Jeju smart grid demonstration project. The Jeju smart grid test-bed electricity market is constructed on the basis of day-ahead and real-time markets to provide two-way electricity transaction environments. The experience of the test-bed market operation shows that the competitive electricity market can facilitate the smart grid deployment in Korea by allowing various demand side resources to be active market players.

Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR 제어봉집합체 낙하성능시험)

  • Lee, Young Kyu;Kim, Hoe Woong;Lee, Jae Han;Koo, Gyeong Hoi;Kim, Jong Bum;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.

Hardware and Software Implementation of a GPS Receiver Test Bed Running from PC (PC 기반 GPS 수신기 하드웨어 모듈 및 펌웨어 개발)

  • Long, Nguyen Phi;Hieu, Nguyen Hoang;Lee, Sang-Hoon;Park, Ok-Deuk;Kim, Hyun-Su;Kim, Han-Sil
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.394-396
    • /
    • 2006
  • When developing a new GPS receiver module, the essential problems are evaluation of reliable algorithms, software debugging, and performance comparison between algorithms to find optimal solution. Most GPS receiver modules nowadays use a correlator to track signals from satellites and an MCU (Micro Controller Unit) to control operations of the entire module. The problem of software evaluation from MCU is very difficult, due to limitation of MCU resources and low ability of interfacing with user. Normally, user has to expense special tool kit for a limiting access to MCU but it is also hard to use. This article introduces an implementation of a GPS receiver test bed using correlator GP2021 interfacing with ISA (Industry Standard Architecture) PC bus. This way can give user complete control and visibility into the operation of the receiver, then user can easily debug program and test algorithms. For this article, the least square method is implemented to test the hardware and software performance.

  • PDF

The Supply Water Algorithm for a Condensing Gas Boiler Control (콘덴싱가스보일러 제어를 위한 공급수알고리즘)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.

Effects of Therapeutic Play Program on the Pre-operative Anxiety of the Preschooler (치료적 놀이 프로그램이 학령전 아동의 수술 전 불안에 미치는 효과)

  • Kim, Jong-Sun
    • Korean Parent-Child Health Journal
    • /
    • v.12 no.2
    • /
    • pp.119-130
    • /
    • 2009
  • Purpose: This study was designed to examine the effects of Therapeutic Play Program on the pre-operative anxiety of the preschoolers. The design of this study is a quasi experimental study of non-equivalent control group pre-test/post-test design. Method: The subjects of this study were the hospitalized preschoolers receiving an operation in C University Hospital. These totalled 60 and were divided into a 30-person-control-group and a 30-person-experimental-group. The data was collected from June 1 to October 5, 2002. The Experimental treatment was carried out according to Therapeutic Play Program developed by Researcher. The instruments used in this study were the observational records for Hospitalized preschooler's Anxiety behavior response, pulse rate, and respiration rate of the preschooler's. The collected data were analyzed with real numbers, percentage, t-test, and $X^2$-test, using SPSS WIN 11.0 program. Result: Hypothesis, "The experimental group provided with a Therapeutic Play Program would show a lower score of the pre-operative anxiety behavior(t=13.79, p=.00), pre-operative pulse(t=4.50, p=.00) and pre-operative respiration rate(t=4.29, p=.00) response than when the control group was not provided", was supported. Conclusion: Therapeutic Play Program is determined to be useful for reducing Pre-operative anxiety of the preschoolers.

  • PDF

IN-PILE PERFORMANCE OF HANA CLADDING TESTED IN HALDEN REACTOR

  • Kim, Hyun-Gil;Park, Jeong-Yong;Jeong, Yong-Hwan;Koo, Yang-Hyun;Yoo, Jong-Sung;Mok, Yong-Kyoon;Kim, Yoon-Ho;Suh, Jung-Min
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.423-430
    • /
    • 2014
  • An in-pile performance test of HANA claddings was conducted at up to 67 GWD/MTU in the Halden research reactor in Norway over a 6.5 year period. Four types of HANA claddings (HANA-3, HANA-4, HANA-5, and HANA-6) and a reference Zircaloy-4 cladding were used for the in-pile test. The evaluation parameters of the HANA claddings were the corrosion behavior, dimensional changes, hydrogen uptake, and tensile strength after the claddings were tested under the simulated operation conditions of a Korean commercial reactor. The oxide thickness ranged from 15 to 37 mm at a high flux region in the test rods, and all HANA claddings showed corrosion resistance superior to the Zircaloy-4 cladding. The creep-down rate of all HANA claddings was lower than that of the Zircaloy-4 cladding. In addition, the hydrogen content of the HANA claddings ranged from 54 to 96 wppm at the high heat flux region of the test rods, whereas the hydrogen content of the Zircaloy-4 cladding was 119 wppm. The tensile strength of the HANA and Zircaloy-4 claddings was similarly increased when compared to the un-irradiated claddings owing to the radiation-induced hardening.

Test Item Set and Evaluation Result Analysis of the Students' Science Inquiry Experiment Tournament (학생 과학탐구 실험대회의 출제와 평가 결과 분석)

  • Lee, Yeung-Ho;Gu, Duc-Kil;Bae, Young-Bu;Paik, Seoung-Hey
    • Journal of The Korean Association For Science Education
    • /
    • v.15 no.1
    • /
    • pp.27-38
    • /
    • 1995
  • The purposes of the 'Students' Science Inquiry Experiment Tournament' which is one of the 'Students' Science Inquiry Olympic Tournaments' are; 1) cultivate students' intellectual interests, inquiry abilities, and scientific attitude dealing with students' scientific reasoning abilities, problem solving abilities, and experimental apparatuses operation abilities. 2) contribute substantiality of science education through experimental inquiry learning. 3) make the ground of basic science development of the future society by selecting excellent students who have talents for science. 4) elevate science teachers' morale by this tournament. The test items set and evaluation results of the tournament were analysed in this study. The results of this study were ; 1) the discrimination ability of the paper-and pencils test and the experiments were low because the students' scores of the items were not normally distributed and standard deviations were very small values. 2) most of the tournament participation students did not answered to the subjective type test items. 3) according to the responses of the tournament participation students, the tournament contribute to the students' interests in science. But the opinion was dominant that the tournament didn't contribute to school science education improvement.

  • PDF

Performance Characteristics of Broadband PLC at Out-door Field Test-bed (저압 인입선에서의 고속 전력선통신 특성 분석)

  • Park Byung-Seok;Yoo Dong-Hee;Hyun Duck-Hwa;Choi Young-Lim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.264-273
    • /
    • 2005
  • Broadband power line communications have been receiving tremendous interest In recent years because this technology enables utilities to deploy a communication network over existing power line infrastructures. Despite the enormous potential, there is some skepticism about the technology and its commercial viability. In this paper, we investigate the performance characteristic of PLC through field test carried out in actual households. Also it addresses major field deployment aspects, such as range, coverage, the number of node for operation and maintenance.