Study on Coal Combustion Characteristics with 1MWth Test Facility

1MWth 실험연소로를 이용한 석탄의 연소특성 연구

  • 장길홍 (한국중공업(주) 기술연구원) ;
  • 장인갑 (한국중공업(주) 기술연구원) ;
  • 정석용 (한국중공업(주) 기술연구원)
  • Received : 1999.04.27
  • Published : 1999.11.01

Abstract

Design and operation of $1MW_{th}$ pulverized coal combustion testing facility are described. Also the influence of air staging on NOx emission and burnout of coal flames was investigated in this facility. The test facility consisted of coal feeding system, firing system and flue gas treatment system. A top-fired externally air staging burner was adopted in order to avoid influence of gravity on the coal particles and for easy maintenance. Distribution of temperature and chemical species concentration of coal flames could be measured in vertical pass of furnace. Main fuel was pulverized (83.4% less than $80{\mu}m$) Australian high bituminous coal. From variety of test conditions, overall excess air ratio was selected at 1.2(20% excess air). Tho study showed that increasing the staged air resulted in lower NOx omission, and it was suggested to be more than 40% of the total combustion air for the substantial NOx reduction. Sufficient burnout was not achievable when NOx emission was less than 500ppm. Also, the amount of core air did not influence tho NOx reduction.