• Title/Summary/Keyword: operation guideline

Search Result 413, Processing Time 0.031 seconds

A Study on Determination of Optimal Reclosing Guideline on Distribution Lines (배전선로 재폐로 최적 기준 산정에 관한 연구)

  • Cho, Jae-Hun;Lee, Sun-Jung;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.417-422
    • /
    • 2022
  • It is always desirable that the continuation of power flow through the lines should not be interrupted for a long time. The optimized guideline of reclosers on distribution lines is known to improve the reliability of power systems, the protection functions on distribution systems heavily rely on the number and placement of such reclosers. This study reviewed the effect of using protection settings methodology with the number of reclosing operations to reduce the damage sustained during faults on distribution networks. The aim of the study is to determine the number of reclosing operations and fault current conditions based on simulation data of PSCAD/EMTDC for standard distribution networks. It is found that the determination of the number of operations on reclosers, which are the protection function of feeders, helped to optimize the operation and reliability of distribution networks.

The Study of Usability Evaluation in the GUI of Mobile Computing - Based on Benchmark Testing in the interface design of WIPI (Mobile Computing의 GUI 개발에 있어 사용성 평가 연구 - WIPI 인터페이스 디자인을 위한 Benchmark Testing을 중심으로 -)

  • 정봉금;송연승
    • Archives of design research
    • /
    • v.17 no.1
    • /
    • pp.49-62
    • /
    • 2004
  • Due to the recent surge of wireless Internet and concurrent development of the end user terminal devices having standardized graphical user interface(GUI) and unified operation mechanism for better interactivity in information representation and ease of use, various efforts on the improvement of GUI is widely recognized as one of the key factors that will usher in the next stages of the wireless Internet for the users. Especially, improved usability along with unique visual effect are considered to be the key elements for GUI considering the rapid improvement of the resolution and color on the end user handset devices; thus, the study and research on the subject of GUI is expected to increase along with the wireless Internet using smart phones. User interface of the wires Internet end user handsets will have a definite and significant effect on the user interaction as well as productivity. Domestically, wireless Internet service providers and GUI design companies are making various efforts in producing a common GUI models for standardized operation scheme and improved graphical display capabilities of the hand phones, PDAs and smart phones. In the study, Nokia 3650 model and Microsoft Orange SPV model were chosen as test devices for usability comparison and data collection to collect directional benchmark data in developing next generation smart phone user interface integrating PDAs and phones. The mail purpose of this study is to achieve the most efficient user accessibility to WAP menu through intensive focus on developing WIPI WAP menu having most effective usability for the users in their twenties and thirties. The result of this study can also be used as the base research materials for WAP service development, VM browser development and PDA browser development. The result of this study along with the evaluation model is expected to provide effective analysis materials on the subject of user interface to the developers of the wireless Internet user devices, GUI designers and service planners while short listing key factors to consider in developing smart phones therefore serving as the GUI guideline of WIPI phones.

  • PDF

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Results of the Precision Monitoring (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(II): 도시가스 및 수송용 - 정밀모니터링 결과 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.57-66
    • /
    • 2019
  • This study carried out on-site investigation and precision monitoring to prepare proper design and operation technical guidelines for the use of bio gas in organic waste resources (fertilizing urine, food waste, food waste, food waste, etc.). According to the government's mid- and long-term policy on bio gasification, the expansion of waste resources is actively being pushed forward. However, facilities that use the biogas produced for urban gas and transportation are still under-efficient. Precision monitoring was carried out for biogasification facilities of organic waste resources in seven locations nationwide. When the results of precision monitoring were summarized with the four-season average, the efficiency analysis of each organic waste resource showed that the organic breakdown rate was 66.3% on average on VS basis. Analysis of biogas characteristics before and after pretreatment revealed that the $H_2S$ average of the entire facility was measured at 949.7 ppm using iron salts and desulfurization (dry, wet) and that the quality refining facility shearing and rear end was 29.0 ppm and 0.3 ppm. The methane content was found to be reduced by 65.6% at the rear of the fire tank, 63.5% at the back and 97.5% at the rear.

Clinical Practice Guideline of Acute Respiratory Distress Syndrome

  • Cho, Young-Jae;Moon, Jae Young;Shin, Ein-Soon;Kim, Je Hyeong;Jung, Hoon;Park, So Young;Kim, Ho Cheol;Sim, Yun Su;Rhee, Chin Kook;Lim, Jaemin;Lee, Seok Jeong;Lee, Won-Yeon;Lee, Hyun Jeong;Kwak, Sang Hyun;Kang, Eun Kyeong;Chung, Kyung Soo;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.4
    • /
    • pp.214-233
    • /
    • 2016
  • There is no well-stated practical guideline for mechanically ventilated patients with or without acute respiratory distress syndrome (ARDS). We generate strong (1) and weak (2) grade of recommendations based on high (A), moderate (B) and low (C) grade in the quality of evidence. In patients with ARDS, we recommend low tidal volume ventilation (1A) and prone position if it is not contraindicated (1B) to reduce their mortality. However, we did not support high-frequency oscillatory ventilation (1B) and inhaled nitric oxide (1A) as a standard treatment. We also suggest high positive end-expiratory pressure (2B), extracorporeal membrane oxygenation as a rescue therapy (2C), and neuromuscular blockage for 48 hours after starting mechanical ventilation (2B). The application of recruitment maneuver may reduce mortality (2B), however, the use of systemic steroids cannot reduce mortality (2B). In mechanically ventilated patients, we recommend light sedation (1B) and low tidal volume even without ARDS (1B) and suggest lung protective ventilation strategy during the operation to lower the incidence of lung complications including ARDS (2B). Early tracheostomy in mechanically ventilated patients can be performed only in limited patients (2A). In conclusion, of 12 recommendations, nine were in the management of ARDS, and three for mechanically ventilated patients.

A Systematic Approach to Decide Maximum Berthing Ship Size Coupled with Berth Design Criteria - A Case of Port of Ulsan - (부두 설계기준을 고려한 접안가능 최대선형의 결정에 관한 연구 - 울산항을 중심으로 -)

  • Jun, Sang-Yup;Kim, Young-Mo;Woo, Byung-Goo;Chung, Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • "Summer Deadweight Tonnage(SDWT)" is used as the criteria of the berthing capacity when establishing port entry limits under current guideline. The important factors affecting to the maximum ship size of possible berthing are mass, length and breath of the ship rather than deadweight. Therefore this guideline should be modified to ensure safety and efficient operation of berth. This study aimed to propose a rational guideline to adjust the berthing capacity. In order to decide proper berthing capacity, three berths of Port of Ulsan were selected and systematic evaluations for the safety of passage transit, berthing maneuvers, ship motions at berth and stabilities of structures were conducted. Small changes of ship size had little effect on those characteristics and little significant differences were found according to the increase of ship size at the same displacement. The evaluation results of the increasement of 50% of berthing capacity at 20,000 DWT, 25% at 40,000 DWT and 13% at 150,000 DWT were within the design criteria in which the berths were built. Therefore, if the channel width, diameter of turning circle, berth length and mooring arrangements are satisfied with the criteria, the current berth limitations should be adjusted by the displacement. as substitute for the deadweight.

  • PDF

A Basic Study for Securing the Business Continuity of Local Governments in the Event of Earthquake and Tsunami (지진 및 지진해일 발생 시 지방자치단체의 업무연속성 확보를 위한 기초 연구)

  • Shin, Hojoon;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.227-234
    • /
    • 2015
  • In this study, the theoretical review was carried out on the concepts regarding the continuity of operation plan and business continuity management plan, international standard ISO22301 and common required functions for disaster response, and the business continuity guideline of local governments in Japan and establishment cases were analyzed to draw matters to be reflected for establishing the business continuity plan of local governments according to the occurrence of earthquake and tsunami. In conclusion, the standard guideline of central government should be prepared for establishing the business continuity plan of local governments and the foundation to establish the plan smoothly based on such guideline should be provided. Also, the business continuity plan should be prepared based on the previous established safety management plans by reflecting the regional characteristics of local governments. And, in order to establish the business continuity plan that fits the region, proper investigations can be carried out to examine the characteristics of each organizations, resources, facilities and environments. Lastly, detailed scenario on the scale of earthquake and tsunami occurrence and damages is prepared to establish the business continuity plan of local governments and conditions for prompt countermeasures according to the scale.

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Optimization of Multi-reservoir Operation considering Water Demand Uncertainty in the Han River Basin (수요의 불확실성을 고려한 한강수계 댐 연계 운영 최적화)

  • Chung, Gun-Hui;Ryu, Gwan-Hyeong;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.89-102
    • /
    • 2010
  • Future uncertainty on water demand caused by future climate condition and water consumption leads a difficulty to determine the reservoir operation rule for supplying sufficient water to users. It is, thus, important to operate reservoirs not only for distributing enough water to users using the limited water resources but also for preventing floods and drought under the unknown future condition. In this study, the reservoir storage is determined in the first stage when future condition is unknown, and then, water distribution to users and river stream is optimized using the available water resources from the first stage decision using 2-stage stochastic linear programming (2-SLP). The objective function is to minimize the difference between target and actual water storage in reservoirs and the water shortage in users and river stream. Hedging rule defined by a precaution against severe drought by restricting outflow when reservoir storage decreases below a target, is also applied in the reservoir operation rule for improving the model applicability to the real system. The developed model is applied in a system with five reservoirs in the Han River basin, Korea to optimize the multi-reservoir system under various future water demand scenarios. Three multi-purposed dams - Chungju, Hoengseong, and Soyanggang - are considered in the model. Gwangdong and Hwacheon dams are also considered in the system due to the large capacity of the reservoirs, but they are primarily for water supply and power generation, respectively. As a result, the water demand of users and river stream are satisfied in most cases. The reservoirs are operated successfully to store enough water during the wet season for preparing the coming drought and also for reducing downstream flood risk. The developed model can provide an effective guideline of multi-reservoir operation rules in the basin.

Evaluation of Residual Radioactivity and Dose Rate of a Target Assembly in an IBA Cyclotron (IBA 사이클로트론 표적집합체에서의 잔류 방사화 분석 및 선량률 평가)

  • Hwang, Seon Yong;Kim, Youngju;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.643-649
    • /
    • 2016
  • When a cyclotron produces $^{18}F^-$, accelerated protons interact with metal parts of the cyclotron machine and induces radioactivity. Especially, the target window and chamber of the target assembly are the main parts where long-lived radionuclides are generated as they are incident by direct beams. It is of great importance to identify radionuclides induced in the target assembly for the safe operation and maintenance of a cyclotron facility. In this study, we analyzed major radionuclides generated in the target assembly by an operation of the Cyclotron 18/9 machine and measured dose rates after the operation to establish the radiation safety guideline for operators and maintenance personnel of the machine. Gamma spectroscopy with HPGe was performed on samples from the target chamber and Havar foil target window to identify the radionuclides generated during the operation for production of $^{18}F^-$- isotope and their specific activity. Also, the dose rates from the target were measured as a function of time after an operation. These data will help improve radiological safety of operating the cyclotron facilities.

Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration (2단 망간모래여과에 의한 고농도 망간 처리)

  • Kim, Chung H.;Yun, Jong S.;Lim, Jae L.;Kim, Seong S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.