• Title/Summary/Keyword: operation characteristic

Search Result 1,478, Processing Time 0.03 seconds

A Study on the Integrated Operation of Product Certification and System Authentication (제품 인증과 시스템 인증의 통합운영에 대한 연구)

  • Choi, Weon-Yong;Rhee, Jong-Tae
    • IE interfaces
    • /
    • v.16 no.4
    • /
    • pp.496-506
    • /
    • 2003
  • This study examines the background and necessity of the product certification (KS) and the system authentication (ISO 9000), and their characteristic so as to compare and analyze the possibility of interaction of product certification and system authentication. It tries to suggest an efficient operation system as an integrated management system and analyzes the certification case of K, a manufacturer of kitchen utensils. We believe that the study will help companies minimize their expenses and efforts to establish, operate, and maintain the corporate standard system. In addition, to effectively achieve our goal, we have also made a study of both literature and case and suggested technical guidance to get integrated management system certification. By these methods, we analyzed the effects and problems that come with the introduction and application of the integrated system of product certification and system authentication in order to set up a system to fit to the mechanism of Korean companies. Moreover, we have suggested the model of integrated operation and the benefits that come after acquiring certification.

Control of Booster Output Voltage in Fuel Cell Power Plant (연료전지발전용 부스터의 출력전압제어 연구)

  • Han, Soo-Bin;Jung, Bong-Man;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1038-1040
    • /
    • 1992
  • Booster is used widely as one of the step-up DC/DC power converter in power conversion process for fuel cell power plant which have the electrical characteristic of the high current density and low cell voltage. In view of control system, booster can be unstable when it is operated in broad operation range because the transfer function of booster has zero in right half plane of s-domain. So for reliable operation, controller must make the system stable in whole working range. In this paper, the two control method such as digital PID control and fuzzy control is studied for booster output voltage regulation in fuel cell plant. The design procedure of PID control and fuzzy control is described. And the experiment of designed controller action is performed in various operation points for controller performance test.

  • PDF

A Computing Switching Angle for Optimal Operation of SRM with Variable Speed Operation (가변속도 구동용 SRM의 최적운전을 위한 스위칭각 산정)

  • Choi Kyeong-Ho;Kim Nam-Hun;Kim Min-Huei;Baik Won-Sik;Kim Dong-Hee;Hwang Don-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.239-243
    • /
    • 2004
  • This paper presents a proper switching angle calculation method of Switched Reluctance Motor (SRM) for drill. The characteristic of SRM drive is very related to the scheduling of commutation angle and current waveforms. Therefore, a selection method of switching turn-on and turn-off angle is suggested for adaptational operation of SRM with varied rotor speed and load. Simulation and experimental results are presented for the validation of proposed method.

  • PDF

The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting (고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석)

  • Song, Jae-Joo;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF

Experimental Analysis of Wheel Radiation Noise of HANVIT 200 Train in Curve Lines (곡선부에서의 한빛 200 열차 차륜방사 소음 특성)

  • Lee, Chan-Woo;Kim, Jae-Chul
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.907-910
    • /
    • 2008
  • The wheel radiation noise characteristic of Korean tilting train(Hanvit 200) on curved rail under the field test conditions is analyzed in this paper. The test railroad track was selected from Seodaejon to Songjeongri in Honam line. $5^{th}$ and $6^{th}$ car are decided to measure radiation noise level among a train of six cars. The test subject curve radius executed from R400, R500, R600, R700 and R800 segments. The speed of test trains when from R600 and R800 curves existing operation speed and speed up 20% of existing speed. On curved rail at the time of operation speed of Hanvit 200 trains from below 95km/h wheel radiation noise level at $94dBA{\sim}99dBA$, the operation speed from between $100km/h{\sim}144km/h$ wheel radiation noise level at $100dBA{\sim}106dBA$.

  • PDF

Wireless Parallel Operation Control of N+1 Redundant UPS System (독립제어구조를 갖는 N+1 모듈형 UPS 시스템의 병렬운전)

  • Cho Jun-Seok;Han Jae-Won;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.734-738
    • /
    • 2002
  • In this paper, a novel wireless parallel operation algorithm of N+1 redundant UPS system with no control interconnections is presented. The load sharing of multiple UPS modules are controlled by Q-V droop and $P-\delta$ droop algorithm. This algorithm compensates for inverter parameter variation and line impedance imbalances with wireless auto-tuning method. And to increase the reliability of transient characteristic under parallel operation, a virtual injected Impedance is proposed to decrease a circulation current between inverter modules. Simulation results are provided to prove the novel wireless algorithm.

  • PDF

Extraction of the Surface Roughness in Grinding Operation by Acoustic Emission Signal (AE 신호에 의한 연삭가공 표면거칠기 검출)

  • Chung, Sung-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.147-153
    • /
    • 1999
  • An in-process extraction method of the ground surface roughness is a bottle-neck and essential field in conventional machining process. We define the D.A.R.F(Dimensionless Average Roughness Factor) that has a roughness characteristic of ground surface. D.A.R.F include the absolute average and the standard deviation values which are the analytic parameters of the AE(Acoustic Emission) signal generated during the grinding operation. The theoretical equation between the surface roughness and the D.A.R.F has been derived from the linear regressive analysis and verified its availability through the experimentation on the surface grinding machine.

  • PDF

Design of Passivity Tele-Operation System Using Fuzzy Wave Variables (퍼지 웨이브 변수를 이용한 수동성 원격 시스템 설계)

  • Park, Beom-Seok;Yoo, Sung-Goo;Chong, Kil-To
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.258-263
    • /
    • 2011
  • In the bilateral tele-operation system, time delay may be a critical problem. Even if system modeling error or time delay occurs, when applied to wave transformation system, the system's stability can be achieved. Using the characteristic b which is an important parameter of wave transformation, the system can display robust performance for time delay. However, since assuming and that the time delay was fixed developing a theory, a stability cannot be guaranteed about the time-varying delay. Therefore, In the paper, Therefore, in this paper, we studied for the method that controls this by applying the fuzzy algorithm which surveyed the timevarying delay characteristics and can adjust the b according to it adaptively.

Parallel Operation Control Technique of On-line UPS System (온라인 무정전전원장치의 병렬운전 제어기술)

  • Cho J.S.;Kang B.H.;Gho J.S.;Choe G.H.;Kim J.H.;Chung S.E.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

Analysis of the Heart Rate Variability Signal in Each Anesthesia Stage using Wigner-Ville Distribution Method (워그너_빌 분포 변환 기법을 이용한 마취단계별 심박변이율 신호 분석)

  • Jeon, Gye-Rok;Kim, Myung-Chul;Yoo, Ju-Yeon;Lee, Hae-Lim;Park, Seong-Min;Shon, Jung-Man;Ye, Soo-Young;Ro, Jung-Hoon;Kim, Gil-Jung;Baik, Seung-Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.103-117
    • /
    • 2010
  • In this study, the heart rate variability(HRV) signal of operating patient was acquired according to anesthesia progress and identified to evaluation possibility of depth of anesthesia in each anesthesia stage. The HRV signal was analyzed time-frequency domain applied to Wigner-Ville distribution method, the characteristic parameters were extracted for evaluation of depth of anesthesia in each anesthesia stage. The progress of general anesthesia was divided into the states of pre-operation, induction of anesthesia, operation, awaking and post-operation.