• Title/Summary/Keyword: operating rating

Search Result 152, Processing Time 0.025 seconds

Performance Test Circuit for a Valve of MMC Based HVDC Power Converter (MMC 기반 HVDC 전력변환기의 밸브 성능 시험회로)

  • Chi-Hwan Bae;Kwang-Rae Jo;Hak-Soo Kim;Eui-Cheol Nho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.76-81
    • /
    • 2023
  • A new test circuit for an MMC-based valve HVDC power converter is proposed. The proposed scheme satisfies the required clauses from IEC-62501. The valve test current contains second harmonic component and DC offset as well as a fundamental component that is quite similar to the real operating arm current of MMC based HVDC power system. The structure of the proposed test circuit is simple compared to conventional test circuits. Furthermore, the power supply voltage rating of the proposed test circuit is reduced dramatically around 20% of the conventional scheme with the same current rating. The validity of the proposed test circuit is verified through simulation and experimental results.

Effects of Distraction using Operating Doll on Preschool Children's Pain during an IV Catheter Insertion (작동인형을 이용한 관심전환이 정맥주사 시 학령전기 아동의 통증에 미치는 효과)

  • Lee Boon-Sim;Kwon In-Soo
    • Child Health Nursing Research
    • /
    • v.11 no.4
    • /
    • pp.490-497
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate the effect on pain of distraction with an operating doll in preschool children(3-6 years old) during an IV catheter insertion. Method: The research design was a nonequivalent control group posttest design, and the participants were 22 children in the experimental group, and 23 children in the control group. The children were hospitalized for enteritis and pharyngitis in a university hospital. The subjective pain was measured using FACES Pain Rating Scale by self report, and the pain behavior responses were scored using Procedure Behavior Check List by observing a film of the entire procedure, and changes in pulse and oxygen saturation as the physiological pain responses were measured by pulse oximeter. Data were analyzed with the SPSS Win 10.0 program. Result: The degree of subjective pain, pain behavior responses, and changes in pulse during IV catheter insertion were significantly lower in the experimental group. But there was no significant difference in $O_2$ saturation between the two groups. Conclusion: Distraction using an operating doll was effective in decreasing pain during inserting the IV catheter in preschool children.

  • PDF

A Numerical Study on Combustion-Stability Rating of Impinging-Jet Injectors Using Hot-Fire Simulation (연소해석을 이용한 충돌형 제트분사기의 연소 안정성 평가에 관한 수치적 연구)

  • Choi, Hyo-Hyun;Sohn, Chae-Hoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.24-31
    • /
    • 2010
  • Combustion-stability rating of impinging-jet injector is conducted numerically using hot-fire simulation in a subscale chamber with the five-element injector head. A sample F(fuel)-O(dxidizer)-O-F impinging-jet injector is adopted. In this work, instantaneous chemical reaction is adopted for hot-fire simulation based on the assumption that mixing process of fuel and oxidizer streams is controlling. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions. The present stability boundaries are in a good agreement with air-injection and hot-fire experimental data. The proposed numerical method can be applied cost-effectively to stability rating of jet injectors when mixing of fuel and oxidizer jets is the dominant process in instability triggering.

Study on Thermal Load Capacity of Transmission Line Based on IEEE Standard

  • Song, Fan;Wang, Yanling;Zhao, Lei;Qin, Kun;Liang, Likai;Yin, Zhijun;Tao, Weihua
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.464-477
    • /
    • 2019
  • With the sustained and rapid development of new energy sources, the demand for electric energy is increasing day by day. However, China's energy distribution is not balanced, and the construction of transmission lines is in a serious lag behind the improvement of generating capacity. So there is an urgent need to increase the utilization of transmission capacity. The transmission capacity is mainly limited by the maximum allowable operating temperature of conductor. At present, the evaluation of transmission capacity mostly adopts the static thermal rating (STR) method under severe environment. Dynamic thermal rating (DTR) technique can improve the utilization of transmission capacity to a certain extent. In this paper, the meteorological parameters affecting the conductor temperature are analyzed with the IEEE standard thermal equivalent equation of overhead transmission lines, and the real load capacity of 220 kV transmission line is calculated with 7-year actual meteorological data in Weihai. Finally, the thermal load capacity of DTR relative to STR under given confidence is analyzed. By identifying the key parameters that affect the thermal rating and analyzing the relevant environmental parameters that affect the conductor temperature, this paper provides a theoretical basis for the wind power grid integration and grid intelligence. The results show that the thermal load potential of transmission lines can be effectively excavated by DTR, which provides a theoretical basis for improving the absorptive capacity of power grid.

A New BUCK ZC-ZVS DC-DC Converter (새로운 강압형 영전류-영전압 컨버터)

  • Lee, Yo-Seob;Won, Young-Jin;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2097-2099
    • /
    • 1998
  • This paper proposed an improvement in the Buck ZC-ZVS converter Presented in [1]. This is achieved by change the auxiliary switch position, which reduces its rating power. By employing saturable inductor, the maximum voltage stress across the main switch becomes constant and independent of the load current. Operating principle of Buck proposed topolo described and confirmed by simulation results.

  • PDF

A Study on the Acoustic Power Estimation in the Blower for a Vehicle Air-handling System (승용차 공조계용 블로우어의 음향출력 평가에 관한 연구)

  • Kim, Seock-Hyun;Yoo, Sung-Woo
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.87-93
    • /
    • 1997
  • A Special purpose program, based on the dimensional analysis, was developed to estimate the wide band turbulent noise in the blower of vehicle airhandling system. Acoustic power level was measured at 4 rating points around the operating condition. The experiment was performed on the reference blower model using international standard chamber, which could measure acoustic power according to the air-handling performance. Analytical model of the blower noise was determined by the measured data. Using the analytical acoustic model, it was possible to estimated the effect by the change of the operating condition, such as flow rate, static pressure and wheel rotating speed, furthermore, the diameter and the width of blower.

  • PDF

A Speed and Power Control of DFIG Using the Exciting Frequency for Wind Power Generating (풍력발전용 권선형 유도발전기의 회전자 여자주파수를 이용한 속도와 출력제어)

  • Lee, U-Seok;O, Cheol-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.349-356
    • /
    • 1999
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed and power control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. For the speed control analysis, torque simulation is performed whereby the different slip between operating motor driving frequency and synchronous frequency of M-G system applied. To keep the output rating of the generator, the exciting frequency and voltage attenuation are applied.

  • PDF

A Study on the Parameter Determination of Synchronous Compensator in AC network with HVDC system (HVDC계통에서 동기조상기의 파라미터 선정에 관한 연구)

  • Lee, Seok-Jin;Lee, Heung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1353-1359
    • /
    • 2010
  • This paper presents the determination of synchronous compensator(S.C) rating and parameter in Cheju AC network. The role of S.C is to supply Inertia and reactive power to HVDC system which is a kind of a generator without the function of reactive power control and Inertia. Therefore, the parameters of S,C have to be determined by considering HVDC operating characteristics. The background of this paper is the determination of S.C parameters in Cheju AC network in the case of replacing current operating S,C to new S.C type.

Design and Implementation of a Broadband Power Divider (광대역전력분배기의 설계 및 제작)

  • Kang, Sanggee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.560-562
    • /
    • 2014
  • Broadband power divider operating over the frequency band assigned for all domestic mobile communications is designed and implemented. The implemented power divider with 20Watts power rating has the maximum insertion loss of 3.49dB, input reflection coefficient of below -18.48dB and output reflection coefficient of below -20.2dB, above 24.7dB isolation and -141.2dBc of 3rd PIMD over the operating frequency of 810 ~ 2620MHz.

A Study of Traction Power System Reliability (철도 급전시스템 신뢰도 평가 연구)

  • Kim Hyungchul;Cha Jun-Min;Kim Jin-O;Han Moonseob
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.806-812
    • /
    • 2005
  • This paper proposes a new reliability evaluation for traction power system. The electric railway consists of traction power systems, various vehicles, operating equipment, track, overhead line and electric equipment. It is a fundamental function of traction power systems that supply customers with reasonable price, acceptable reliability and high quality power. In a general way, the power system reliability deals with the ability to satisfy load demands in supply capability or rating of every factor. On the other hand, the reliability of traction power systems has been focused on train time delay caused by power outage. In this paper, we make a selection optimum reliability indices for the reliability evaluation of electric traction power systems. The reliability study not only applies a plan for traction supply system after detecting the vulnerable point of existing traction supply systems but also makes a role in stable operating railway.

  • PDF