• Title/Summary/Keyword: open and closed circuit

Search Result 55, Processing Time 0.033 seconds

Intelligent Video Surveillance Incubating Security Mechanism in Open Cloud Environments (개방형 클라우드 환경의 지능형 영상감시 인큐베이팅 보안 메커니즘 구조)

  • Kim, Jinsu;Park, Namje
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.5
    • /
    • pp.105-116
    • /
    • 2019
  • Most of the public and private buildings in Korea are installing CCTV for crime prevention and follow-up action, insider security, facility safety, and fire prevention, and the number of installations is increasing each year. In the questionnaire conducted on the increasing CCTV, many reactions were positive in terms of the prevention of crime that could occur due to the installation, rather than negative views such as privacy violation caused by CCTV shooting. However, CCTV poses a lot of privacy risks, and when the image data is collected using the cloud, the personal information of the subject can be leaked. InseCam relayed the CCTV surveillance video of each country in real time, including the front camera of the notebook computer, which caused a big issue. In this paper, we introduce a system to prevent leakage of private information and enhance the security of the cloud system by processing the privacy technique on image information about a subject photographed through CCTV.

Fabrication and effect of different temperatures on the supported thin Anode for molten carbonate fuel cell (용융탄산염 연료전지에서 지지체를 사용한 얇은 연료극의 제작과 각기 다른 온도에서의 영향)

  • Park, Dongnyeok;Giulio, Nicola Di;Seo, Dongho;Yoon, Sungpil;Shul, Yonggun;Han, Jonghee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.82.1-82.1
    • /
    • 2010
  • Recently, Molten carbonate fuel cells(MCFCs) have been developing to get a good durability and economic feasibility for commercialization. To achieve these objectives, the cost of nickel based electrodes should be reduced. Regular anode thickness used in MCFCs is normally 0.7mm. Thus, in our study, the purpose was to reduce anode thickness up to 0.3 mm keeping MCFC performance on standard levels. In-situ sintering has been used, with 2 different fabrication methods (method A and B) and 2 different supports (support 1 and 2). Voltage losses at different temperature (600,620,640,$650^{\circ}C$) and after 1000 hours showed the higher performance that can be obtained using method B and support 2. After single cell test, an open-circuit voltage(OCV) of 1.075 V and a closed-circuit voltage(CCV) of 0.829V were obtained, at current density of $150mV/cm^2$. Also the voltage loss ratio at different cell temperature was lower in the case of method B and support 2. According to these results, the cost of anode fabrication can be reduced in the future, contributing for the economical feasibility of MCFCs.

  • PDF

Relationship between Contrast Ratio of Conductive Particle and Contact Resistance on COG Bonding using ACF (ACF를 이용한 COG 접합 공정에서 도전볼의 음영비와 접촉 저항과의 관계)

  • Jin, Songwan;Jeong, Young Hun;Choi, Eun Soo;Kim, Bosun;Yun, Won-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.831-838
    • /
    • 2014
  • Chip on glass (COG) bonding using anisotropic conductive film (ACF) is a key technology to assemble a driver IC onto a LCD glass panel. In this paper, an experimental investigation was conducted to investigate the correlation between contact resistance and characteristics of image taken by machine vision based inspection system. The results show that the contact resistance was strongly influenced by the contrast ratio of conductive particle rather than the number of conductive particles. Also, number of conductive particles whose contrast ratio is below 0.75 is crucial for determining the quality of the assembled samples. On the other hand, in the result of high temperature high humidity storage test, the contrast ratio of samples was increased. However, in the case of open-circuit samples after temperature humidity storage test, the number of conductive particles whose contrast ratio is above 0.75 was more than that of the closed-circuit samples.

Comparative Study on the Basal Metabolism used by Douglas-Scholander and Sanborn Metabulator Method (기초대사 측정에 있어 Douglas-Scholander법과 Sanborn-Metabulator를 사용한 성적의 비교검토)

  • Kim, Dong-Jun;Kim, Myung-Hee;Chung, Ae-Soon
    • The Korean Journal of Physiology
    • /
    • v.11 no.2
    • /
    • pp.57-61
    • /
    • 1977
  • Two methods have been widely used for measuring basal metabolic rates (BMR), Douglas-Scholander (open circuit) and Sanborn-Metabulator (closed circuit ) methods. The latter has been used more by clinicians, since the Process is simple. But it is not as accurate as the Douglas-Scholander method. We measured the BMR of 938 healthy individuals who were selected at random, using a Douglas-Scholander method. The lowest value of the 6 measurments in three days was taken from each subject in the basal state. A single determination of BMR also was made with the Metabulator for 684 individuals. We applied both methods for 13 subjects among them who have same physical conditions. The results obtained were as follows: 1. The mean value of BMR with the Metabulator is significantly higher than Douglas-Scholander method by 9.2%. 2. The Metabulator can be used for measuring BMR, since the normal value is generally less than 15% of BMR. But one may considered that there is likely errors about 10% in Metabulator method.

  • PDF

Development of an active gust generation mechanism on a wind tunnel for wind engineering and industrial aerodynamics applications

  • Haan, Fred L. Jr.;Sarkar, Partha P.;Spencer-Berger, Nicholas J.
    • Wind and Structures
    • /
    • v.9 no.5
    • /
    • pp.369-386
    • /
    • 2006
  • A combination Aerodynamic/Atmospheric Boundary Layer (AABL) Wind and Gust Tunnel with a unique active gust generation capability has been developed for wind engineering and industrial aerodynamics applications. This facility is a cornerstone component of the Wind Simulation and Testing (WiST) Laboratory of the Department of Aerospace Engineering at Iowa State University (ISU). The AABL Wind and Gust tunnel is primarily a closed-circuit tunnel that can be also operated in open-return mode. It is designed to accommodate two test sections ($2.44m{\times}1.83m$ and $2.44m{\times}2.21m$) with a maximum wind speed capability of 53 m/s. The gust generator is capable of producing non-stationary gust magnitudes around 27% of the mean flow speed. This paper describes the motivation for developing this gust generator and the work related to its design and testing.

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

A Mind Switch using EEG (EEG를 이용한 마인드 스위치 제작)

  • Ahn, Soon-Kwan;Jun, Sang-Beom;Kim, Sung-June
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.211-212
    • /
    • 1998
  • In this experiment, we developed a mind switching device which uses $\alpha$-wave with its amplitude varying between the eye-open and closed states. If the subject closes eyes, the switch toggles with a small delay. The circuit consists of an amplifier, a filter and a switch. An instrument amplifier is used fur high CMRR and for high input impedance. An 8th order Butterworth filter was able to reduce noise satisfactorily. The signal is then converted to a DC level, and finally a Schmitt trigger was used to generate a switching pulse.

  • PDF

Conformance Test and Analysis for Interoperability of Video Surveillance System based on ONVIF (ONVIF 기반 영상보안시스템 상호연동 적합성 평가 및 분석)

  • Lee, Gilbeom;Lim, Chaehun;Kwon, Donghyun;Lee, Eunhyang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.381-383
    • /
    • 2016
  • 본 논문에서는 영상보안시스템을 구성하는 장비 간의 상호연동 적합성을 평가하는 방법과 분석 결과를 제시한다. 꾸준한 성장세를 보이고 있는 영상보안시스템 분야는 기존의 아날로그 CCTV(Closed Circuit TeleVision) 체계 대신 네트워크 인터페이스 기반의 시스템으로 변화하고 있다. 이에 따라 IP(Internet Protocol) 기반의 네트워크 환경에서 장비 간 연동을 위해 국제적으로 ONVIF(Open Network Video Interface Forum), PSIA(Physical Security Interoperability Alliance)와 같이 여러 CCTV 제조사들이 모인 산업계 포럼에서 장비 간 상호호환성을 위해 인터페이스 프로토콜을 정의하고 자체 표준화를 주도하고 있다. 이에 본 논문은 TTA에서 국내 영상보안시스템의 상호운용성을 위해 개발한 ONVIF 기반의 상호연동 인증 기준을 기반으로 영상보안시스템 장비 중 하나인 IP 카메라와 NVR(Network Video Recorder)에 대해 상호연동 적합성을 평가하는 방법을 설명하고 분석 결과를 제시한다.

  • PDF

Hybrid Type Structure Design and DLT-Replacement Circuit of the High-Speed Frequency Synthesizer (고속 스위칭 동작의 주파수 합성기를 위한 하이브리드형 구조 설계와 DLT 대체 회로 연구)

  • Lee Hun-Hee;Heo Keun-Jae;Jung Rag-Gyu;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.12 s.91
    • /
    • pp.1161-1167
    • /
    • 2004
  • The conventional PLL(phase locked loop) frequency synthesizer takes a long switching time because of the inherent closed-loop structure. The digital hybrid PLL(DH-PLL) which includes the open-loop structure into the conventional PLL synthesizer has been studied to overcome this demerit. It operates in high speed, but the hardware complexity and power consumption are the serious problem because the DLT(digital look-up table) is usually implemented by the ROM which contains the transfer characteristic of VCO(voltage controlled oscillator). This paper proposes a new DH-PLL using a very simple DLT-replacement digital logic instead of the complex ROM-type DLT. Also, a timing synchronization circuit for the very small over-shoot and shorter settling time is designed for the ultra fast switching speed at every frequency synthesis. The hardware complexity gets decreased to about $28\%,$ as compared with the conventional DH-PLL. The high speed switching characteristic of the frequency synthesis process can be verified by the computer simulation and the circuit implementation.

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF