• Title/Summary/Keyword: oneM2M standards

Search Result 148, Processing Time 0.029 seconds

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.

Synthesis, Sytructure, and Magnetic Properties of One-Dimensional Thiophoshates, $Al_2NiP_2S_6$ (A=Rb, Cs) (1차원 구조를 갖는 Thiophoshates, $Al_2NiP_2S_6$ (A=Rb, Cs)의 합성, 구조 및 자기적 성질)

  • Dong, Yong Kwan;Lee, Kun Soo;Yun, Ho Seop;Hur, Nam Hwi
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.3
    • /
    • pp.242-246
    • /
    • 2001
  • The quaternary thiophosphates, $A_2NiP_2S_6$ (A=Rb, Cs), have been synthesized with halide fluxes and structurally characterized by single-crystal X-ray diffraction technique. These compounds crystallize in the space group $C_{2h}^5-P2_1/n$ of the monoclinic system with two formula units in a cell of dimensions a=5.960(2), b=12.323(4), $c=7.491(3)\AA$, $\beta=97.05(3)^{\circ}$, and $V=546.0(3)\AA^3$ for Rb2NiP2S6 and a=5.957(4), b=12.696(7), $c=7.679(4)\AA$, $b=93.60(5)^{\circ}$, and $V=579.7(5)\AA^3$ for $Cs_2NiP_2S_6.$ These compounds are isostructural. The structure of $Cs_2NiP_2S_6$ is made up of one-dimensional $_\infty^1[NiP_2S_6^{2-}]$ chains along the a axis and these chains are isolated by $Cs^+$ ions. The Ni atom is octahedrally coordinated by six S atoms. These Ni$S_6$ octahedral units are linked by sharing three m-S atoms of the $[P_2S_6^{4-}]$ anions to form the infinite one-dimensional $_\infty^1[NiP_2S_6^{2-}]$ chain. For $Cs_2NiP_2S_6$, the magnetic susceptibility reveals an antiferromagnetic exchange interaction below 8K,which corresponds to the Neel temperature ($T_N$). Above $T_N$, this compound obeys Curie-Weiss law. The magnetic moment, C, and ${\theta}forCs_2NiP_2S_6$ are 2.77 B.M., 0.9593 K, and -19.02 K, respectively. The effective magnetic moment obtained from the magnetic data is agreed with the spin-only value of $Ni^{2+}d^8$(2.83 B.M.) system.

  • PDF

Evaluation of the Reproducibility of Radiation Output from Diagnostic X-ray Equipment(Standards Based on IEC 60601-2-54) (진단용 X선 장치에서 방사선출력의 재현성 평가(IEC 60601-2-54 표준규격을 기반으로))

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;Hong, Dong-Hee;Kim, Chang-Gyu;You, In-Gyu;Mo, Eun-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.555-561
    • /
    • 2014
  • For five diagnostic X-ray generators (DR), four units turned out to be appropriate in tests on the reproducibility of radiation output suggested in the IEC 60601-2-54 standard, but in one unit of the X-ray equipment, an item measured in a combination of 50% of the highest tube voltage of the diagnostic X-ray equipment, the test setting of Group C with authorized output doses between $1{\mu}Gy$ and $5{\mu}Gy$ of mAs turned out to be inappropriate. As a result, the radiation dose to the IEC 60601-2-54 standard for quantification standards proposed by the radiation output from diagnostic X-ray imaging device reproducibility of performance management should be aware that an important evaluation factor.

Proposal of the Measurement Conditions for Hanji-Determination Folding Endurance (한지 내절 강도 시험의 측정조건 제안)

  • Kim, Myoung Nam;Kim, Ji Won;Son, Ha Nuel;Jeong, Sun Wha
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.689-700
    • /
    • 2021
  • This study aims to optimize the measurement conditions of handmade Hanji paper to reduce the time required for measurement while meeting folding endurance standards, for various basis weights. Thirteen types were selected, including 12 types of Hanji with grammages of 17 g/m2, 30 g/m2, and 45 g/m2, and one type of 75 g/m2 copy paper, and 24 sheets were prepared in the laid and chain directions. Subsequently, folding endurance experiments at different load (14.72 N, 9.81 N, 4.91 N) and specimen width conditions (15 mm, 10 mm, 5 mm) were performed, using a 4-MIT folding endurance tester. The results showed that, for specimen widths of 15 mm and 10 mm under a load of 4.91 N, the folding endurance falls within the reference range (10~10000 times). In particular, reduced folding endurance range and measurement time were observed at a width of 10 mm under a load of 4.91 N. Moreover, the endurance trend lines based on the average values of load and specimen width ranges enabled the prediction of the folding endurance within those ranges, according to the decreasing slope. Furthermore, for a specimen width of 15 mm under a load of 4.91 N, the folding endurance in the comparison group (35 to 17723 times) significantly exceeds the upper limit of the reference range (10~10000 times). Therefore, the measurement conditions of 4.91 N with a specimen width of 10 mm are proposed.

Antibiotics Susceptability of Streptococcus pneumoniae Isolated from Pharynx in Healthy Korean Children and Choice of Proper Empirical Oral Antibiotics Using Pharmacokinetics/Pharmacodynamics Model (국내의 소아에서 분리된 폐구균의 항생제 감수성 양상 및 약력동학 모델을 이용한 적절한 항생제의 선택)

  • Paik, Ji Yeun;Choi, Jae Hong;Cho, Eun Young;Oh, Chi Eun;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.2
    • /
    • pp.109-116
    • /
    • 2011
  • Purpose : Pneumococcus is one of the most important causes of invasive infection through the childhood period. In January 2008, the Clinical and Laboratory Standards Institute (CLSI) published revised penicillin breakpoints for Streptococcus pneumoniae and penicillin susceptibility rates of S. pneumoniae increased in Korea. This study was performed to determine the probability of oral amoxicillin for the empirical treatment achieving bactericidal exposure against pneumococcus using pharmacodynamics model. Methods : Twenty-three isolates of pneumococci were subjected to determine minimum inhibitory concentration (MIC) for ${\beta}$-lactams and macrolide. For the ${\beta}$-lactams, exposure of fT >MIC (time that free drug concentrations remain above the MIC) for 50% of the administration interval have determined the probability of target attainment (PTA), and regimens that had a PTA >90% were considered optimal. An analysis was performed by applying MIC of 23 isolates to a 5000-patient Monte Carlo simulation model. Results : Among 23 isolates from healthy children, 7 (30.4%) isolates were MIC ${\leq}$1.0 ${\mu}g$/mL and 19 (82.6%) were MIC ${\leq}$2 ${\mu}g$/mL for amoxicillin. Amoxicillin 40 mg/kg/day achieved PTA >90% at MIC ${\leq}$1.0 ${\mu}g$/mL but PTA decreased to 52% at MIC 2 ${\mu}g$/mL, whereas amoxicillin 90 mg/kg/day can predict 97% of PTA at MIC 2 ${\mu}g$/mL. Overall, oral amoxicillin 90 mg/ kg/day for the empirical treatment against pneumococcus can expect more successful response in Korean children. Conclusion : Considering the resistantce pattern of pneumococci in Korean children, we estimate that oral amoxicillin 90 mg/kg/day will provide a pharmacodynamic advantage for the empirical treatment against pneumococcus. And low dose amoxicillin or macrolide are expected to have higher chance of treatment failure than high dose oral amoxicillin.

Characterization of Forest Fire Emissions and Their Possible Toxicological Impacts on Human Health

  • Kibet, Joshua;Bosire, Josephate;Kinyanjui, Thomas;Lang'at, Moses;Rono, Nicholas
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.2
    • /
    • pp.113-121
    • /
    • 2017
  • In flight particulate matter particularly emissions generated by incomplete combustion processes has become a subject of global concern due to the health problems and environmental impacts associated with them. This has compelled most countries to set standards for coarse and fine particles due to their conspicuous impacts on environment and public health. This contribution therefore explores forest fire emissions and how its particulates affects air quality, damage to vegetation, water bodies and biological functions as architects for lung diseases and other degenerative illnesses such as oxidative stress and aging. Soot was collected from simulated forest fire using a clean glass surface and carefully transferred into amber vials for analysis. Volatile components of soot were collected over 10 mL dichloromethane and analyzed using a QTOF Premier-Water Corp Liquid Chromatography hyphenated to a mass selective detector (MSD), and Gas Chromatograph coupled to a mass spectrometer (GC-MS). To characterize the size and surface morphology of soot, a scanning electron microscope (SEM) was used. The characterization of molecular volatiles from simulated forest fire emissions revealed long chain compounds including octadec-9-enoic acid, octadec-6-enoic acid, cyclotetracosane, cyclotetradecane, and a few aromatic hydrocarbons (benzene and naphthalene). Special classes of organics (dibenzo-p-dioxin and 2H-benzopyran) were also detected as minor products. Dibenzo-p-dioxin for instance in chlorinated form is one of the deadliest environmental organic toxins. The average particulate size of emissions using SEM was found to be $11.51{\pm}4.91{\mu}m$. This study has shown that most of the emissions from simulated forest fire fall within $PM_{10}$ particulate size. The molecular by-products of forest fire and particulate emissions may be toxic to both human and natural ecosystems, and are possible precursors for various respiratory ailments and cancers. The burning of a forest by natural disasters or man-made fires results in the destruction of natural habitats and serious air pollution.

Identification of Causes and Prevention Measures for Health Disorders Such as Erythema of Restaurant Workers in Manufacturing Company (제조사업장 식당 종사자의 홍반 등 건강장해 원인 규명 및 예방 방안)

  • Jee Yeon Jeong;Gwangyong Yi;Seung-Hyeon Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.3
    • /
    • pp.238-246
    • /
    • 2024
  • Objectives: A collective of workers in the company's cafeteria encountered symptoms such as stinging and watering in and around the eyes, a sensation of sand in the eyes, erythema, swelling, and peeling of the skin on the face and neck. The objective of this study is to pinpoint the causes of these symptoms and propose preventive measures. Methods: Following preliminary on-site investigations, worker interviews, and literature research, it was determined that the most probable cause of the symptoms was ultraviolet rays emitted from a UV sterilizer. Consequently, the study measured and assessed the effective amount of ultraviolet radiation emitted by the sterilizer. Results: When operating with the curtain-type door of the ultraviolet sterilizer open, it was observed to surpass the 0.1 μW/cm2 8-hour work exposure standard recommended by ACGIH TLV in most kitchen workspaces. The evaluation of the maximum allowable exposure time based on the distance from the ultraviolet sterilizer indicated only 4.2 seconds at a distance of 0.2 m with the curtain door open, and merely 1.7 minutes at a distance of 1 m. Conclusions: This study confirmed that the symptoms among restaurant workers emerged immediately after the installation of the ultraviolet sterilizer, and these symptoms were consistent with those associated with exposure to ultraviolet rays. Furthermore, the assessment revealed that the exposure level to ultraviolet rays could be exceeded established exposure standards. It was recommended that the existing ultraviolet sterilizer be replaced with one featuring a glass door, and facility improvements should be made, such as implementing an automatic mechanism to turn off the ultraviolet lamp when the door is opened.

Comparison and Decision of Exposure Coefficient for Calculation of Snow Load on Greenhouse Structure (온실의 적설하중 산정을 위한 노출계수의 비교 및 결정)

  • Jung, Seung-Hyeon;Yoon, Jae-Sub;Lee, Jong-Won;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.226-234
    • /
    • 2015
  • To provide the data necessary to determine exposure coefficients used for calculating the snow load acting on a greenhouse, we compared the exposure coefficients in the greenhouse structure design standards for various countries. We determined the exposure coefficient for each region and tried to improve on the method used to decide it. Our results are as follows: After comparing the exposure coefficients in the standards of various countries, we could determine that the main factors affecting the exposure coefficient were terrain roughness, wind speed, and whether a windbreak was present. On comparing national standards, the exposure coefficients could be divided into three groups: exposure coefficients of 0.8(0.9) for areas with strong winds, 1.0(1.1) for partially exposed areas, and 1.2 for areas with dense windbreaks. After analyzing the exposure coefficients for 94 areas in South Korea according to the ISO4355 standard, all of the areas had two coefficients (1.0 and 0.8), except Daegwallyeong (0.5) and Yeosu (0.6), which had one coefficient each. In South Korea, the probability of snow is greater inland than in coastal areas and there are fewer days with a maximum wind velocity > $5m{\cdot}s^{-1}$ inland. When determining the exposure coefficients in South Korea, we can subdivide the country into three regions: coastal areas with strong winds have an exposure coefficient of 0.8; inland areas have a coefficient of 1.0; and areas with dense windbreaks have an exposure coefficient of 1.2. Further research that considers the number of days with a wind velocity > $5m{\cdot}s^{-1}$ as the threshold wind speed is needed before we can make specific recommendations for the exposure coefficient for different regions.

In Vitro Antifungal Activity of (1)-N-2-Methoxybenzyl-1,10-phenanthrolinium Bromide against Candida albicans and Its Effects on Membrane Integrity

  • Setiawati, Setiawati;Nuryastuti, Titik;Ngatidjan, Ngatidjan;Mustofa, Mustofa;Jumina, Jumina;Fitriastuti, Dhina
    • Mycobiology
    • /
    • v.45 no.1
    • /
    • pp.25-30
    • /
    • 2017
  • Metal-based drugs, such as 1,10-phenanthroline, have demonstrated anticancer, antifungal and antiplasmodium activities. One of the 1,10-phenanthroline derivatives compounds (1)-N-2-methoxybenzyl-1,10-phenanthrolinium bromide (FEN), which has been demonstrated an inhibitory effect on the growth of Candida spp. This study aimed to explore the in vitro antifungal activity of FEN and its effect on the membrane integrity of Candida albicans. The minimum inhibitory concentration (MIC) and the minimum fungicidal concentration (MFC) of FEN against planktonic C. albicans cells were determined using the broth microdilution method according to the Clinical and Laboratory Standards Institute guidelines. Cell membrane integrity was determined with the propidium iodide assay using a flow cytometer and were visualized using scanning electron microscopy (SEM). Planktonic cells growth of C. albicans were inhibited by FEN, with an MIC of $0.39-1.56{\mu}g/mL$ and a MFC that ranged from 3.125 to $100{\mu}g/mL$. When C. albicans was exposed to FEN, the uptake of propidium iodide was increased, which indicated that membrane disruption is the probable mode of action of this compound. There was cells surface changes of C. albicans when observed under SEM.

Application of Field and Laboratory Emission Cell (FLEC) to Determine Formaldehyde and VOCs Emissions from Wood-Based Composites

  • Kim, Sumin;Kim, Jin-A;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.24-37
    • /
    • 2007
  • The Korean Ministry of Environment started controlling indoor air quality (IAQ) in 2004 through the introduction of a law regulating the use of pollutant emitting building materials. The use of materials with formaldehyde emission levels above $1.25 mg/m^2{\cdot}h$ (JIS A 1901, small chamber method) has been prohibited. This level is equivalent to the $E_2$ grade ($>5.0mg/{\ell}$) of the desiccator method (JIS A 1460). However, the $20{\ell}$ small chamber method requires a 7-day test time to obtain the formaldehyde and volatile organic compound (VOC) emission results from solid building interior materials. As a approach to significantly reduce the test time, the field and laboratory emission cell (FLEC) has been proposed in Europe with a total test time less than one hour. This paper assesses the reproducibility of testing formaldehyde and TVOC emissions from wood-based composites such as medium density fiberboard (MDF), laminate flooring, and engineered flooring using three methods: desiccator, perforator and FLEC. According to the desiccator and perforator standards, the formaldehyde emission level of each flooring was ${\le}E_1$ grade. The formaldehyde emission of MDF was $3.48 mg/{\ell}$ by the desiccator method and 8.57 g/100 g by the perforator method. To determine the formaldehyde emission, the peak areas of each wood-based composite were calculated from aldehyde chromatograms obtained using the FLEC method. Formaldehyde, acetaldehyde, propionaldehyde, butyraldehyde and benzaldehyde were detected as aldehyde compounds. The experimental results indicated that MDF emitted chloroform, benzene, trichloroethylene, toluene, ethylbenzene, m,p-xy-lene, styrene, and o-xylene. MDF emitted significantly greater amounts of VOCs than the floorings did.