• Title/Summary/Keyword: one-way measurement

Search Result 535, Processing Time 0.031 seconds

Analysis of the Process Capability Index According to the Sample Size of Multi-Measurement (다측정 표본크기에 대한 공정능력지수 분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.151-157
    • /
    • 2019
  • This study is about the process capability index (PCI). In this study, we introduce several indices including the index $C_{PR}$ and present the characteristics of the $C_{PR}$ as well as its validity. The difference between the other indices and the $C_{PR}$ is the way we use to estimate the standard deviation. Calculating the index, most indices use sample standard deviation while the index $C_{PR}$ uses range R. The sample standard deviation is generally a better estimator than the range R. But in the case of the panel process, the $C_{PR}$ has more consistency than the other indices at the point of non-conforming ratio which is an important term in quality control. The reason why the $C_{PR}$ using the range has better consistency is explained by introducing the concept of 'flatness ratio'. At least one million cells are present in one panel, so we can't inspect all of them. In estimating the PCI, it is necessary to consider the inspection cost together with the consistency. Even though we want smaller sample size at the point of inspection cost, the small sample size makes the PCI unreliable. There is 'trade off' between the inspection cost and the accuracy of the PCI. Therefore, we should obtain as large a sample size as possible under the allowed inspection cost. In order for $C_{PR}$ to be used throughout the industry, it is necessary to analyze the characteristics of the $C_{PR}$. Because the $C_{PR}$ is a kind of index including subgroup concept, the analysis should be done at the point of sample size of the subgroup. We present numerical analysis results of $C_{PR}$ by the data from the random number generating method. In this study, we also show the difference between the $C_{PR}$ using the range and the $C_P$ which is a representative index using the sample standard deviation. Regression analysis was used for the numerical analysis of the sample data. In addition, residual analysis and equal variance analysis was also conducted.

Relationship between Characteristics of Five Types of Obese Woman based on Physical Tests and Fei-kao-liuren based on Oriental Medical Theory (여성(女性) 비만(肥滿) 유형별 검사특성과 비고육인(肥膏肉人)과의 관계)

  • Jin Seng-Hee;Choi Kyung-Mee;Park Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.27 no.2 s.66
    • /
    • pp.145-154
    • /
    • 2006
  • Objectives : Methods to evaluate obesity are growing to be important in studying links between health and disease. Physicians are using BMI (body mass index) to evaluate obesity, but they can't know how much fat the body has by using that method. Even though there are several assessments, there are different scales, so patients are diagnosed as obese, by some but not by others. These studies are limited in evaluating obesity; it is necessary to study based on new knowledge. According to Oriental Medical Theory, obese people are categorized into 3 types, Fei, Kao and Liu Ren. They have different pathology and body shapes than non-obese people. The relationship between Oriental Medical Theory and BMI and assessment of body fat is a fundamental need to easily approach and treat obesity. Methods : At 00 Oriental Medical Center, 145 female subjects who intended to lose weight were given physical tests and grouped into 5 types of obesity. The physical tests were height measurement, BMI, body composition (body fat mass and lean body mass), skin elasticity and physical strength tests. One-way analysis of variance was done to compare the means of physical tests between the five types of obese women. There was some relationship between characteristics of the five types based on physical tests and Fei, Kao and Liu Ren based on Oriental Medical Theory. Least significant difference (LSD) was used in multiple comparisons. Results : 1. According to the skin elasticity test, obesity type 5 placed between obesity types 3 and 4 and obesity types 1 and 2. Obesity types 3 and 4 were in the low skin elasticity result group; obesity types 1 and 2 were in the high ones (p<0.1).Based on Oriental Medical Theory, Fei Ren and Kao Ren can be distinguished by skin elasticity degree. This result should form the basis of obesity diagnosis. 2. According to Oriental Medical Theory, Fei Ren is smaller than others. Based on height measurement, obesity types 3 and 4 were significantly lower than other obesity types (p<0.1), so there is a relationship between Fei Ren and obesity types 3 & 4. 3. There were significant differences between obesity type 2 and obesity type 4 in the body fat mass result (p<0.1). This study did not have large enough a sample size to distinguish Liu Ren. Conclusions : Further clinical research is necessary to study measurement methods of body shape type and skin elasticity for distinguishing Fei Ren from Kao Ren. The diagnosis and treatment based on the relationship of these types should be studied further.

  • PDF

Uncertainty evaluation of dioxin analysis in blood samples (혈액 시료 중 다이옥신의 농도 분석 결과에 대한 불확도 평가)

  • Mun, Su-Jung;Kim, Byung-Hoon;Woo, Jin-Chun;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.475-482
    • /
    • 2003
  • Uncertainty of final measurement results considering main uncertainty sources being in dioxin analysis of a blood sample was estimated. 'The Guide to the Expression of Uncertainty in Measurement' was suggested for accomplishment of this study. After uncertainties for the 11 compounds detected in this experiment of the 17 target compounds of dioxin and furan were calculated considering the uncertainty sources of each step, uncertainty for the total dioxin concentration was estimated by combining these values. The concentration of dioxin in blood sample was expressed as $0.0746{\pm}0.0074pg$ I-TEQ/g weight or $20.68{\pm}2.04pg$ I-TEQ/g lipid, including the uncertainty values obtained in this way. The former expression indicates the conversion concentration into the sample weight and the latter one indicates the conversion concentration into the lipid weight. The quality of measured analytical results could be assured quantitatively by estimating uncertainty of measurement results and showing the range of measurand.

Real-time Discharge Measurement of the River Using Fixed-type Surface Image Velocimetry (고정식 표면영상유속계 (FSIV)를 이용한 실시간 하천 유량 산정)

  • Kim, Seo-Jun;Yu, Kwon-Kyu;Yoon, Byung-Man
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.5
    • /
    • pp.377-388
    • /
    • 2011
  • Surface Image Velocimetry (SIV) is a recently-developed discharge measurement instrument. It uses image processing techniques to measure the water surface velocity and estimate water discharge with given cross section. The present study aims to implement a FSIV (Fixed-type Surface Image Velocimetry) at Soojeon Bridge in the Dalcheon. The hardware system consists of two digital cameras, a computer, and a pressure-type water stage gauge. The images taken with the hardware system are sent to a server computer via a wireless internet, and analyzed with a image processing software (SIV software). The estimated discharges were compared with the observed discharges through Goesan dam spillway and index velocity method using ADVM. The computed results showed a good agreement with the observed one, except for the night time. The results compared with discharges through Goesan dam spillway reached around 5~10% in the case of discharge over 30 m3/s, and the results compared with discharges through index velocity method using ADVM reached around 5% in the case of discharge over 200 $m^3/s$. Considering the low cost of the system and the visual inspection of the site situation with the images, the SIV would be fairly good way to measure water discharge in real time.

A Study on the Application of UBC3D-PLM for Soil Liquefaction Analysis (액상화 해석을 위한 UBC3D-PLM의 적용성에 관한 연구)

  • Park, Eon-Sang;Kim, Byung-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, a model parameter evaluation method using relative density was proposed to utilize applicable UBC3D-PLM for liquefaction behavior. In addition, dynamic effective stress analysis, that is, liquefaction analysis, was performed on the case of the liquefaction occurrence region where acceleration and pore water pressure were measured, and compared with the actual measurement and the existing Finn analysis results. Through this study, it was found that the proposed method can easily evaluate the necessary parameters required by the related model and predict the pore water pressure behavior in the region where liquefaction occurs. In addition, in the case of the study area, both measurements and numerical analysis showed that liquefaction occurred when a certain amount of time elapsed after the earthquake acceleration reached the maximum value. In the case of UBC3D-PLM applied in this study, the excess pore water pressure behavior similar to the actual measurement was predicted, and the occurrence of liquefaction was evaluated in the same way as the actual measurement. In particular, although the excess pore water pressure in the sand layer was greater, the phenomenon in which liquefaction occurred in the silt layer was accurately realized. It is expected that the proposed model parameter evaluation method and finite element analysis applying UBC3D-PLM can be used to select the liquefaction reinforcement region in the future seismic design and reinforcement by evaluating the liquefaction occurrence region similarly to the real one.

A Study on the 3D Measurement Data Application: The Detailed Restoration Modeling of Mireuksajiseoktap (미륵사지석탑 정밀복원모형 제작을 중심으로 한 3차원 실측데이터의 활용 연구)

  • Moon, Seang Hyen
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.2
    • /
    • pp.76-95
    • /
    • 2011
  • After dismantled, Mireuksajiseoktap(Stone pagoda of Mireuksa Templesite) is being in the stage of restoration design. Now, different ways - producing restoration model, a 3 dimension simulation - have been requested to make more detailed and clearer restoration design prior to confirmation of its restoration design and actual restoration carry-out. This thesis proposes the way to build the detailed model for better restoration plan using extensively-used Reverse Engineering technique and Rapid Prototyping. It also introduces each stage such as a 3-dimension actual measurement, building database, a 3-dimension simulation etc., to build a desirable model. On the top of that, this thesis reveals that after dismantled, MIruksaji stone pagoda's interior and exterior were not constructed into pieces but wholeness, so that its looks can be grasped in more virtually and clearly. Secondly, this thesis makes a 3-dimension study on the 2-dimension design possible by acquiring basic materials about a 3-dimension design. Thirdly, the individual feature of each member like the change of member location can be comprehended, considering comparing analysis and joint condition of member. Lastly, in the structural perspective this thesis can be used as reference materials for structure reinforcement design by grasping destructed aspects of stone pagoda and weak points of the structure. In dismantlement-repair and restoration work of cultural properties that require delicate attention and exactness, there may be evitable errors on time and space in building reinforcement and restoration design based on a 2-dimension plan. Especially, the more complicate and bigger the subject is, the more difficult an analysis about the status quo and its delicate design are. A series of pre-review, based on the 3-dimension data according to actual measurement, can be one of the effective way to minimize the possibility that errors about time - space happen by building more delicate plan and resolving difficulties.

Self-Efficacy and Self-Control Effects on Purchasing Intention of Annuity Savings Plans: Considering Financial Literacy (금융 유통산업에서의 자기효능감과 자기통제가 연금저축 가입의도와 가입행동에 미치는 영향: 금융이해력에 따른 차이분석)

  • Lee, Yun-Bok;Lee, Phil-Soo;Hwang, Jae-Kwang
    • Journal of Distribution Science
    • /
    • v.13 no.11
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose - Economic status at an early stage of life after one's retirement is often determined by the long-term sacrifice of one's earlier consumption tendencies. In general, the first and foremost way to secure income after retirement is through annuity savings. People sign up for personal annuity savings in order to guarantee a stable economic life upon retirement, and such actions may be heavily influenced by self-efficacy. Confidence in current economic activity is a source of rational decision-making. Inability to achieve self-control can lead to reckless spending and the eventual hindering of proper investment for the future. This paper examines how self-efficacy and self-control affect the intention and action of enrolling in an annuity savings plan in relation to one's level of financial literacy. Research design, data, and methodology - To analyze the proposed model, this study investigates financial consumers over the age of 20. The data were collected from 511 respondents and analyzed with SPSS 21.0 and AMOS 21.0. First, for the one-dimensional test and to measure the convergent validity of each structure, we use the scale purification process. The results of the test and the confirmatory factor analysis ensure the focus of the validity of the single dimension for each structure. In addition, the validity of the measurement was guaranteed from the results of correlation analysis. Results - First, self-efficacy and self-control have positive effects on the purchasing intention of the personal annuity savings plan. Second, purchasing intention positively affects purchasing behavior. Lastly, self-control has a positive effect on purchasing intention among the low financial literacy group, whereas self-efficacy does not have this effect in the high financial literacy one. Conclusions - The time of product benefit is different with age. The younger group would be granted the savings after several decades once they enroll, whereas the older group would wait for a relatively shorter period of time. Therefore, further research should be conducted in order to verify such a difference. However, this study has value through its confirmation that the roles of self-efficacy and self-control play a part in leading to the enrollment in annuity savings plans and by verifying different effects based on levels of financial literacy. Such results suggest a number of implications in a real life setting. First, banks need to put greater emphasis on the stability of annuity savings in general. Second, customers with relatively low levels of financial literacy are able to control their finances through annuity savings, but find self-efficacy difficult due to a lack of financial understanding. Therefore, such customers should be approached from an invest-effectiveness comparison method. Third, customers with high financial literacy tend to put more value in rational economic decision-making and behavior than in self-efficacy. Therefore, such customers should be approached by promoting the reliability of annuity savings and the excellence of the specific bank's annuity savings plan in comparison to those of other financial institutions.

The Effects of Upper and Lower Limb Coordinated Exercise in One Leg Support or non Support on Gait Ability in Chronic Stroke Patients (한 발 지지 유무에 따른 상하지 협응운동이 만성 뇌졸중 환자의 보행능력에 미치는 영향)

  • Kuk, Eun-Ju
    • Journal of Digital Convergence
    • /
    • v.11 no.7
    • /
    • pp.281-288
    • /
    • 2013
  • The purpose of this study was to identify the effects of upper and lower limb coordinated exercise for gait ability in stroke patients. Upper and lower limb coordinated exercise method was conducted in two different groups; one is an one leg support group and the other is a non support group. In this study, 14 patients were participated. One leg support group was applied to 7 patients, and non support group was applied to 7 patients. Both group carried out 3 times a week for 30 minutes during 4 weeks. Data were analyzed statistically via Repeated two-way ANOVA, Mann-Whitney U test, and Friedman test. The results of the measurement analysis were summarized as follows: 1. There were significant differences in 10MWT among 2 groups after intervention(p<.05). 2. There were significant differences in F8WT, FSST among 2 groups after intervention(p<.05). According to Bonferroni test, one leg support group had significant increased from pre-intervention to post-4 week. However, there were no significant differences in nonsupport group. In conclusion, improvement of gait ability in chronic stroke patients was effect to upper and lower limb coordinated exercise.

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Investigation of osseointegration according to the healing time after having iatrogenic mobility of implant fixtures (임플란트 고정체의 인위적 비틀림 후 시간 경과에 따른 골재유착 반응에 관한 연구)

  • Hwang, Yun-Jin;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.308-314
    • /
    • 2010
  • Purpose: The purpose of this study is to analyze the change in re-osseointegration over time and bone reaction at the interface between implant fixture and the surface of the bone, after destroying re-osseointegration by distorting the bone-implant interface artificially. Materials and methods: Experimental implant fixtures (cp titanium, ${\phi}3.75\;mm{\times}4\;mm$) which didn't have surface treatment were produced. Two or three fixtures were implanted on both tibias of twelve female rabbits (New Zealand white, more than 3.5 kg). Then after six weeks, removal torque (RT) was measured and the results were recorded as the first measurement values. The fixtures were submerged again to get reosseointegration between the bone and fixture. To identify the change in re-osseointegration of submerged fixtures over time, six groups had the healing time for four days (group I), one week (group II), two weeks (group III), three weeks (group IV), four weeks (group V) and five weeks (group VI), and then the secondary removal torque was measured for each group. To identify the bone formation under fluorescent light, tetracycline (15 mg/kg, IM) were treated on the rabbits of each group. After the second measurement, the rabbits were sacrificed, and 16 slides were made, two or three for each group. The slides were observed under the fluorescent light with light microscope. To find out the change in the secondary removal torque over the primary removal torque in progress of time, the averages of the increase rate of the primary and secondary torque removal force were calculated. Then, to find out if there were any critical differences between the primary removal torque and the secondary removal torque in each group and among the groups, the results were analyzed statistically by paired t- test, one-way ANOVA, and Duncan's Multiple Range Test. Results: In group I and II, secondary removal torque decreased, especially in group I. In group III, IV, V, and VI, secondary removal torque increased critically. Comparing the differences among the groups, the critical difference was shown between group I, II and group III, IV, V, VI. Mineralization at the interface between the bone and implant fixture was identified from the first week, and bone formation was shown more clearly from the second week. Conclusion: If the implant fixture remains unforced for a certain period of time after the fixture has had iatrogenic mobility, re-osseointegration occurs at the surface of the fixture, and for tibias of rabbits, higher re-osseointegration was obtained within two weeks.