• Title/Summary/Keyword: on-site testing

Search Result 450, Processing Time 0.028 seconds

On-Line System for Partial Monitoring Discharge (온라인 부분방전 감시 시스템)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

A study on the improvements of geotechnical properties of in-situ soils by grouting

  • Chang, Muhsiung;Mao, Tze-wen;Huang, Ren-chung
    • Geomechanics and Engineering
    • /
    • v.10 no.4
    • /
    • pp.527-546
    • /
    • 2016
  • This paper discusses improvements of compressibility, permeability, static and liquefaction strengths of in-situ soils by grouting. Both field testing and laboratory evaluation of the on-site samples were conducted. The improvement of soils was influenced by two main factors, i.e., the grout materials and the injection mechanisms introduced by the field grouting. On-site grout mapping revealed the major mechanism was fracturing accompanied with some permeation at deeper zones of sandy soils, where long-gel time suspension grout and solution grout were applied. The study found the compressibility and swelling potential of CL soils at a 0.5 m distance to grout hole could be reduced by 25% and 50%, respectively, due to the grouting. The effect on hydraulic conductivity of the CL soils appeared insignificant. The grouting slightly improved the cohesion of the CL soils by 10~15 kPa, and the friction angle appeared unaffected. The grouting had also improved the cohesion of the on-site SM soils by 10~90 kPa, while influences on the friction angle of soils were uncertain. Liquefaction resistances could be enhanced for the sandy soils within a 2~3 m extent to the grout hole. Average improvements of 40% and 20% on the liquefaction resistance were achievable for the sandy soils for earthquake magnitudes of 6 and ${\geq}7.5$, respectively, by the grouting.

Web Accessibility of Major Korean Web sites (국내 주요 웹사이트의 접근성에 관한 분석)

  • Lee, Yang-Kyu
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.4
    • /
    • pp.33-44
    • /
    • 2005
  • Universal accessibility of web sites Is critical in a highly interconnected world. The web site should be usable by anyone, regardless of Individual capabilities and disabilities. But in reality, the users with disabilities are discriminated by inaccessible wed sites. This research analyze the accessibility of major web sites of Korea based on World Wide Web Consortium's Web Content Accessibility Guideline 1.0. The result shows that the average number of accessibility errors per web site is 2.77 much higher than that of Unites States. Automated testing and manual testing of web accessibility provides complementary results.

  • PDF

Usability testing of the domestic web site design : questionnaire and heuristic evaluation (국내 웹 사이트 디자인의 사용성 조사 : 설문조사 및 발견평가)

  • 곽호완;곽지은;김수진;이정모
    • Korean Journal of Cognitive Science
    • /
    • v.11 no.1
    • /
    • pp.33-45
    • /
    • 2000
  • The present study examined the usability of the web site design, focusing on the cognitive characteristics of the WWW. Specifically, we conducted two major non-experimental usability testing methods on the domestic web sites with various purposes. In research I. we used an on-line questionnaire method on 12 domestic web sites. As a result. several critical usability features and factors were identified. In research 2. we carried out a heuristic evaluation method to identify more specific usability problems The result of research 2 suggests that the heuristic evaluation method reveals more specific problems of the web site design than the questionnaire method.

  • PDF

A Case Study on System Evaluation of the KOLIS-NET (KOLIS-NET의 시스템 평가에 관한 연구)

  • Kim, Young-Kee;Lee, Soo-Sang
    • Journal of the Korean Society for information Management
    • /
    • v.23 no.1 s.59
    • /
    • pp.261-278
    • /
    • 2006
  • This study aims to evaluate KOLIS-NET system by usefulness testing of 'KOLIS-NET client integrated system' and by usability testing of 'KOLIS-NET web site'. For evaluating the usefulness of the system, we used searching, ease of use, customer support as criteria, and used brainstorming and in-depth interview as evaluation method. On the other hand, for usability testing of the web site, we used cognitive walkthrough. Evaluation results are categorized and represented as page redesign, term consistency, function improvement and new functionality.

Investigation and Analysis of Soil Contamination at Industrial Site (산업공장 주변 토양오염도 조사 분석)

  • 정하익;김상근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.99-102
    • /
    • 2000
  • There has been a steady increase in contaminated ground at municipal and industrial site. In this study, investigation and analysis on soil contamination at industrial site was carried out. Testing contaminated soils were sampled at this site. As a result of this study, the concentration of soil was investigated, and measured concentration was compared with related concentration criteria.

  • PDF

A Study on Site Application Techniques for Insulation Reliability of Rotating Machine (고압회전기 절연열화진단의 현장적용기술연구)

  • Kim, K.Y.;Jo, K.H.;Kim, T.S.;Han, S.O.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.286-291
    • /
    • 1991
  • Most of the failures of rotating machine are stator coil insulation failures. The insulation diagnostic testing for high voltage motors and generators are only megger test and P. I Test which is applied DC voltage until now. But it was impossible to judge insulation deterioration status of high voltage rotating machinery by above testing. In other words, even though the megger measurement values are fairly high, they used to be failed from time to time. Therefore in order to excute reliable and detailed diagnosis of insulation deterioration for rotating machinery, the tangent delta test, the alternating current test and the partial discharge test shall be applied to the insulation diagnostic testing on site.

  • PDF

A Source Code Cross-site Scripting Vulnerability Detection Method

  • Mu Chen;Lu Chen;Zhipeng Shao;Zaojian Dai;Nige Li;Xingjie Huang;Qian Dang;Xinjian Zhao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.6
    • /
    • pp.1689-1705
    • /
    • 2023
  • To deal with the potential XSS vulnerabilities in the source code of the power communication network, an XSS vulnerability detection method combining the static analysis method with the dynamic testing method is proposed. The static analysis method aims to analyze the structure and content of the source code. We construct a set of feature expressions to match malignant content and set a "variable conversion" method to analyze the data flow of the code that implements interactive functions. The static analysis method explores the vulnerabilities existing in the source code structure and code content. Dynamic testing aims to simulate network attacks to reflect whether there are vulnerabilities in web pages. We construct many attack vectors and implemented the test in the Selenium tool. Due to the combination of the two analysis methods, XSS vulnerability discovery research could be conducted from two aspects: "white-box testing" and "black-box testing". Tests show that this method can effectively detect XSS vulnerabilities in the source code of the power communication network.

Orofacial Thermal Quantitative Sensory Testing (QST): A Study of Healthy Korean Women and Sex Difference

  • Ahn, Sung-Woo;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.3
    • /
    • pp.96-101
    • /
    • 2015
  • Purpose: Thermal sensory test as an essential part of quantitative sensory testing (QST) has been recognized as a useful tool in the evaluation of the trigeminal nerve function. Normative data in the orofacial region have been reported but the data on differences in the test site, sex and ethnicity are still insufficient. Thus, this study aimed to investigate the normal range of orofacial thermal QST data in the healthy Korean women, and assess sex difference of thermal perception in the orofacial regions. Methods: Thermal QST was conducted on 20 healthy women participants (mean age, 26.4 years; range, 21 to 34 years). The thermal thresholds (cold detection threshold, CDT; warm detection threshold, WDT; cold pain threshold, CPT; and heat pain threshold, HPT) were measured bilaterally at the 5 trigeminal sites (the forehead, cheek, mentum, lower lip and tongue tip). The normative thermal thresholds of women in the orofacial region were evaluated using one-way ANOVA and compared with the previously reported data from age- and site-matched 30 healthy men (mean age, 26.1 years; range, 23 to 32 years) using two-way ANOVA. One experienced operator performed the tests of both sexes and all tests were done in the same condition except the time variability. Results: Women showed significant site differences for the CDT (p<0.001), WDT (p<0.001), and HPT (p=0.047) in the orofacial region. The CDT (p<0.001) and the CPT (p=0.007) presented significant sex difference unlike the WDT and the HPT. Conclusions: The thermal sensory evaluation in the orofacial region should be considered in the context of site and sex and the normative data in this study could be useful for assessment of the sensory abnormalities in the clinical setting.

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.