• 제목/요약/키워드: on-site investigation

검색결과 1,235건 처리시간 0.032초

Fluorescence Characteristic Spectra of Domestic Fuel Products through Laser Induced Fluorescence Detection

  • Wu, Ting-Nien;Chang, Shui-Ping;Tsai, Wen-Hsien;Lin, Cian-Yi
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권5호
    • /
    • pp.18-25
    • /
    • 2014
  • Traditional investigation procedures of soil and groundwater contamination are followed by soil gas sampling, soil sampling, groundwater sampling, establishment of monitoring wells, and groundwater monitoring. It often takes several weeks to obtain the analysis reports, and sometimes, it needs supplemental sampling and analysis to delineate the polluted area. Laser induced fluorescence (LIF) system is designed for the detection of free-phase petroleum pollutants, and it is suitable for on-site real-time site investigation when coupling with a direct push testing tool. Petroleum products always contain polycyclic aromatic hydrocarbon (PAH) compounds possessing fluorescence characteristics that make them detectable through LIF detection. In this study, LIF spectroscopy of 5 major fuel products was conducted to establish the databank of LIF fluorescence characteristic spectra, including gasoline, diesel, jet fuel, marine fuel and low-sulfur fuel. Multivariate statistical tools were also applied to distinguish LIF fluorescence characteristic spectra among the mixtures of selected fuel products. This study successfully demonstrated the feasibility of identifying fuel species based on LIF characteristic fluorescence spectra, also LIF seemed to be uncovered its powerful ability of tracing underground petroleum leakages.

시추공 정보의 클러스터링 기법을 이용한 지반분석시스템의 개발 (Development of a Subsurface Exploration Analysis System Using a Clustering Technique on Bore-Hole Information)

  • 이규병;김유성;조우석;김영진
    • Spatial Information Research
    • /
    • 제8권2호
    • /
    • pp.301-315
    • /
    • 2000
  • 지반조사 자료는 구조물을 시공하거나 설계하기 위해 필요한 기본자료이며 지층의 구성, 토질의 종류 등 기반을 구별하는 정보를 포함한다. 매년 대량으로 발생하는 지반조사 자료들은 현장의 특성을 정확하게 반영하기 때문에 지반조사 자료를 이용하여 지반을 분석한다면, 기존의 지질도나 토양도보다 뛰어난 결과를 얻을 수 있다. 따라서 비균질하고 비정형화된 지반의 특성을 고려하여 서로구별하는 특징을 추출하고, 현장의 특성을 정확하게 반영하는 지반분석 시스템이 필요하다. 본 논문은 지반조사 정보 시스템이 관리하고 있는 시추공의 지층구성 정보와 위치 근접성을 바탕으로 시추공을 클러스터링하여 지반의 구성을 분석하는 지반분석시스템의 설계 및 구현에 대해 전반적으로 기술하였다. 개발된 지반분석시스템은 지반조사 데이터베이스의 시추공 정보를 이용하여 지반이 가지고 있는 특성 정보를 추출하고, 이를 이용하여 유사한 특성 및 위치 근접성을 갖는 시추공의 집합으로 클로스터링하여 사용자에게 정확한 지반구성 정보를 제공하는 시스템이다. 또한, 수치지도의 사용으로 지리적 위치와 지역·지형에 대한 지반구조의 특성조사를 가능하게 하며, 지반조사를 필요로 하는 지역에 대한 지반의 유추가 가능하여 경제적 효과를 볼 수 있다. 따라서, 지반조사 데이터로부터 다양한 종류의 정보를 얻을 수 있으며 지질도나 토양도보다 정확한 지반특성을 제공할 수 있다.

  • PDF

양산물금지구 피압수 특성에 관한 연구 (A Study of Artesian Characteristics in Yangsan/Mulgeum Site)

  • 한영철;유갑용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.123-130
    • /
    • 1999
  • This paper presents a study of geotechnical treatment for artesian pressure after extensive investigation was performed on the distribution and characteristics of artesian condition which exists at Yangsan/Mulgeurn site. The result of analysis indicates that the artesian pressure seems to be up to 2.9M above the existing ground surface, originating from the higher ground water recharging sources in the surrounding hills and mountains. There is no harmful effect after the site development since the height of embankment is more than 4M above the existing ground surface.

  • PDF

지반조사 정보의 3차원 가시화 시스템 개발 (The Development of 3-D System for Visualizing Information on Geotechnical Site Investigation)

  • 홍성완;배규진;서용석;김창용;김광염
    • 지질공학
    • /
    • 제12권2호
    • /
    • pp.179-188
    • /
    • 2002
  • 최근 컴퓨터 성능 및 컴퓨터 가시화 기술의 발달에 힘입어 지반공학 분야의 지반조사결과를 가시화 할 수 있는 소프트웨어들이 출시되고 있다. 지반조사의 중요한 목적 중 하나는 건설대상 부지 내에 분포하는 건설에 불리하게 작용하는 불확실성을 예측하고 파악하는 것이다. 이들 불확실성은 시공의 안정성을 떨어뜨릴 뿐만 아니라 공기를 지연시키고 공사비를 증가시킨다. 3차원 가시화 기법은 이러한 지반의 불확실성을 극복할 수 있는 좋은 도구중 하나이다. 본 논문에서는 터널설계 및 시공분야에 3차원 가시화 기술, GIS 기술, 데이터베이스 기술을 적용하기위하여 새롭게 개발된 시스템을 소개한다. 가상현실과 3차원 가시화 기술은 지반구조 및 특성을 3차원 모델화 하는데 사용되었으며, 데이터베이스 기술과 GIS 기술을 접목하여 지반조사와 터널시공 중에 획득되는 지반정보를 데이트베이스화 하였다. 본 시스템을 이용함으로서 초목 엔지니어는 설계단계에서 계획을 세울 때 지반조사 정보를 유용하게 이용할 수 있고, 시공단계에서 공사의 안정성 및 경제성을 극대화시킬 있을 것이다.

비위생매립지 복원사업을 위한 지반환경특성 정밀조사 (Investigation of Abandoned Waste Landfill for Rehabilitation)

  • 정하익;김상근;유준;이용수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.475-482
    • /
    • 2004
  • The purpose of this paper is to study on the investigation of abandoned waste landfill for rehabilitation. The geotechnical and environmental field and laboratory tests for wastes dumped at municipal site were carried out. Testing wastes were sampled at the illegal landfill site The various samples such as waste. soil, groundwater, gas, leachate were taken in the landfill site. As a result of this study, the engineering properties and concentration of samples were investigated The result of this study was used for introduction the rehabilitation method and treatment of unregulated closed landfill.

  • PDF

부지특성화을 위한 지하수의 수리화학 특성 연구: 주성분 분석을 중심으로 (Hydrochemical Investigation for Site Characterization: Focusing on the Application of Principal Component Analysis)

  • 유순영;김한석;전성천;이종화;윤성택;권만재;조호영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권spc호
    • /
    • pp.34-50
    • /
    • 2022
  • Principal component analysis (PCA) was conducted using hydrochemical data in four testbeds (A to D) built for the development of site characterization technologies to assess the hydrochemical processes controlling the hydrochemistry in each site. The PCA results indicated the nitrogen loading to deep bedrock aquifers through permeable fractures in Testbed A, the chemical weathering enhanced with the biodegradation of petroleum hydrocarbons in Testbed B, the reductive dechlorination in Testbed C, and the different hydrochemistry depending on the depth to bedrock in Testbed D, consistent with the characteristics of each site. In Testbeds B and D, outliers seemed to affect the PCA result probably due to the small number of samples, whereas the PCA result was still consistent with site characteristics. This study result indicates that the PCA is widely applicable to hydrochemical data for the assessment of major hydrochemical processes in contamination sites, which is useful for site characterization when combined with other site characterization technologies, e.g., geological survey, geophysical investigation, borehole logging. It is suggested that PCA is applied in contaminated sites to interpret hydrochemical data not only for the distribution of contamination levels but also for the assessment of major hydrochemical processes and contamination sources.

상주시 신도심의 복합건축물 실태조사를 통한 계획방향에 관한 연구 (A Study on the planning approach through the Actual Research of Complex Buildings in the New Town of Sangju)

  • 이근택;정용호
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.85-93
    • /
    • 2004
  • This study does try to proceed on the assumption that complex buildings can vitalize urban life of contemporary society from contemporary complexity and cases of past failure. The scope of investigation on complex buildings in Sangju built in 1990s' and 2000s' on this thesis is that site size is 400 square meter, total area 1500 square meter, and the number of stories on the ground below 5 floor. Method of investigation on twenty one buildings which have been built on new C.B.D. between the Namwon avenue and the Joongang 1th street in Sangju is through field investigation, field photographs, recordings and drawings on these buildings. Investigative contents have been divided and analysized into physical and functional elements in urban and architectural dimension. On the basis of these results, the future planning approach of complex buildings in medium and small cities has been considered into planning principles of convenience of building use and efficiency of site size, physical plans reflected on the traffic and pedestrian movings and the face of buildings, pedestrian resting space-creation like plazas and central gardens, regional character reflected with urban context, and separation and union of approached movings interrelated among the components.

현장조사에 의한 접지시스템의 전기안전성 평가 (Assessment of Electrical Safety for Grounding System by Investigation on the Spot)

  • 길형준;김동우;김동욱;이기연;김향곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2008
  • This paper deals with assessment of electrical safety for grounding system of buildings by investigation on the spot at construction site. The investigation was carried out for grounding method, grounding type, shape of grounding electrode, grounding for lightning protection system, continuity of steelwork in reinforced concrete structure and so on. The investigation on the spot was performed by researcher, engineer with over fifteen years of industry experience all over the country. As a result of investigation on the spot to 13 buildings, common grounding method was dominant. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding. use of surge protective device.

  • PDF

NaDCC (sodium dichloroisocyanurate) 성분 가습기살균제 유사제품의 특성과 의료기관에서의 사용 사례 (Characteristics of Humidifier Disinfectant-like Products Containing NaDCC (sodium dichloroisocyanurate) and Their Use in Hospitals)

  • 조은경;한경희;주민재;양원호;최윤형
    • 한국환경보건학회지
    • /
    • 제46권5호
    • /
    • pp.495-503
    • /
    • 2020
  • Objective: This study aimed to compare the characteristics of humidifier disinfectant-like products (HD-like products) and humidifier disinfectant products (HD products) and introduce actual cases of the usage of HD-like products in hospitals based on an on-site investigation. Methods: The characteristics, chemical components, and usage of HD-like products (Hichlor or Biospot) and HD products (N-with) containing NaDCC (sodium dichloroisocyanurate) were compared. In the process of conducting the on-site investigation, four hospitals were identified as previously using HD-like products. Each on-site investigation to identify the use of HD-like products was composed of four parts: 1) hospital infection control guidelines, 2) manual for humidifiers in patient's rooms, 3) interviews with nursing staff, infection managers, and purchase managers, 4) searching on the product purchase system. Results: Although HD-like products (Hichlor and Biospot) and HD products (N-with) were sold for different usage purposes, they were all white-colored and coin-shaped foaming tablets with the same chemical component, NaDCC. The manual for using HD-like products and HD products was similar (inserting the tablet in a humidifier container with water). Among the four hospitals, one had used Hichlor in the same manner as HD (N-with) by inserting a tablet in 1L of water in a filled humidifier container and Biospot as a kind of detergent for humidifier container cleaning. Another two hospitals had used Biospot and/or Aniosyme as a kind of detergent for humidifier container cleaning. The other hospital had used unknown product in the same manner as N-with, so we thus assumed it was either an HD products (N-with) or HD-like products (Hichlor, Biospot). Conclusion: This study raises the possibility of the development of adverse health effects similar to exposure to an HD-products when exposed to an HD-like products and the possibility of further use in other medical institutions or multi-use facilities. Therefore, an expansion of the investigation is needed in order to confirm whether there have been similar cases in the past.

전기비저항 탐사를 이용한 노은매립장 침출수 분포에 관한 연구 (A Study on Electrical Resistivity Geophysical Surveys of the Noen Landfill Site)

  • 김준경;홍상표;김광렬;조용진
    • 환경영향평가
    • /
    • 제13권5호
    • /
    • pp.223-230
    • /
    • 2004
  • The electrical resistivity prospecting method with dipole-dipole array were applied in order to survey 3-D structure characteristics of the Noen landfill site. For the electrical resistivity prospecting, 3 line of measurements were established parallel to the main boundary of the Noen landfill site and additional 2 lines were also established perpendicular to the existing 3 lines for the effective investigation of the landfill site. The results showed that the uppermost layer of the landfill site is believed to be stabilized generally based on the characteristics of electrical resistivity distribution. Lowest layer was partially polluted by the leachate.