• Title/Summary/Keyword: on-line estimation

Search Result 983, Processing Time 0.028 seconds

Characteristic Estimation of Single-Stage Active-Clamp Type High Frequency Resonant Inverter (단일 전력단 능동 클램프형 고주파 공진 인버터의 특성 평가)

  • 원재선;강진욱;김동희
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.2
    • /
    • pp.114-122
    • /
    • 2004
  • This paper presents a novel single-stage active-clamp type high frequency resonant inverter. The proposed topology is integrated full-bridge boost rectifier as power factor corrector and active-clamp type high frequency resonant inverter into a single-stage. The input stage of the full-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. By adding additional active-clamp circuit to conventional class-E high frequency resonant inverter, main switch of inverter part operates not only at Zero-Voltage-Switching mode but also reduces the switching voltage stress of main switch. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics estimation through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in the fields of induction heating applications, fluorescent lamp and DC-DC converter etc.

A Study on the Estimation of Software Development Cost of IT Projects in Public Sector (공공부문 정보화사업의 소프트웨어 개발비용 예측에 관한 연구)

  • 박찬규;구자환;김성희;신수정;송병선
    • Korean Management Science Review
    • /
    • v.19 no.2
    • /
    • pp.191-204
    • /
    • 2002
  • As the portion of information systems (IS) budget to the total government budget becomes greater, the cost estimation of IS development and maintenance projects is recognized as one of the most important problems to be resolved for scientific and efficient management of IS budget. Since IS budget makes much effect on the delivery time, quality and productivity of IS projects, the exact cost estimation is also necessary for the successful accomplishment of IS projects. The primary concern in the cost estimation of IS projects is software cost estimation, which requires the measurement of the size of softwares. There are two methods for sizing software : line-of-code approach, function point model. In this paper, we propose a function-point-based model for estimating software cost. The proposed model is derived by collecting about fifty domestic IT projects in public sector and analyzing their relationship between cost drivers and development effort. Since the proposed model is developed by simplifying the function point model that can be used only when detailed user requirements are specified, it can be also applied at project planning and budgeting phase.

Quality of Departure Time Based On-line Link Travel Time Estimates (구간통행속도 추정을 위한 고속도로 검지기자료 처리기법 개발)

  • Park, Dong-Joo;Kim, Jae-Jin;Rho, Jung-Hyun;Kim, Sang-Beom
    • International Journal of Highway Engineering
    • /
    • v.10 no.1
    • /
    • pp.145-154
    • /
    • 2008
  • The purpose of this study is to evaluate the quality of on-line departure time-based link travel time estimates. For this, accuracy (i.e. estimation error) and timeliness (i.e. degree of time lag) are proposed as MOE of the quality of on-line link travel time estimates. Then the relationship between quality of link travel time estimates and link length and level of congestion is analyzed. It was found that there is trade-off between the accuracy and timeliness of link travel time estimates. The estimation error was modeled to consist of two components: one is systematic error and the other is mean square error which reflects level of congestion. further, time lag was again segmented into three parts for the analysis purpose. There are minimum one, congestion-related one, and update interval-related one. From the real-world data using AVI system, it was revealed that regardless of the link length and level of congestion, 10 minutes of time lag occurs in general.

  • PDF

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

Design of optimal P.I.D controller for unknwon long time delayed system (시간지연이 큰 미지의 시스템에 대한 최적 P.I.D 제어기 설계)

  • 박익수;문병희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.164-167
    • /
    • 1996
  • This paper presents an off-line P.I.D parameter estimation method during normal operation in power plant. The process parameters are estimated using the recursive least square method. The controller parameters are estimated on the basis of desired characteristics of the dynamic model of the closed-loop control.

  • PDF

The Analysis of Protection -Characteristics and Fault-Locator Simulation on the Electrical Railway (교류전기철도 보호특성 해석 및 고장점표정 시뮬레이션)

  • 창상훈;이장무
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.262-269
    • /
    • 1998
  • In case the fault occurs in AC power supply network, protective relaying system must selectively detect line-to-line/ground fault and immediately cut off the power flow into the fault location for guaranteeing the safety of people, electric vehicle and ground installation etc. It is the most important point in power system operation to minimize the fault duration by rapid trip scheme and accurate estimation of the fault location. In this paper, we analyze the load characteristics of each vehicle, perform the fault analysis of AC power supply network using AT current-ratio method. The result shows its usefulness.

  • PDF

DC-Link Capacitance Estimation using Support Vector Regression in AC/DC/AC PWM Converters (SVR을 이용한 AC/DC/AC PWM 컨버터의 직류링크 커패시턴스 추정)

  • Ahmed G. Abo-Khalil;Jang, Jeong-Ik;Lee, Dong-Choon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.81-87
    • /
    • 2007
  • This paper proposes a new capacitance estimation scheme for a DC-link capacitor in a three-phase AC/DC/AC PWM converter. A controlled AC voltage with a lower frequency than the line frequency is injected into the DC-link voltage, which then causes AC power ripples at the DC side. By extracting the AC voltage and power components on the DC output side using digital filters, the capacitance can then be calculated using the Support Vector Regression (SVR). By training of SVR, a function which relates a given input (capacitor's power) and its corresponding output (capacitance value) can be derived. This function is used to predict outputs for given inputs that are not included in the training set. The proposed method does not require the information of DC-link current and can be simply implemented with only software and no additional hardware. Experimental results confirm that the estimation error is less than 0.16%.

Capacitance Estimation of DC-Link Capacitors of Three-Phase AC/DC/AC PWM Converters using Input Current Injection (입력전류 주입을 이용한 3상 AC/DC/AC PWM 컨버터의 직류링크 커패시터 용량 추정)

  • 이강주;이동춘;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.173-179
    • /
    • 2003
  • In this paper, a novel on-line dc capacitance estimation method for the three-phase PWM converter is proposed. At no load, input current at a low frequency is injected, which causes dc voltage ripple. With the at voltage and current ripple components of the dc side, the capacitance can be calculated. Experimental result shows that the estimation error is less than 2%.

Flicker Estimation for Wind Turbine Systems using SVR (SVR을 이용한 풍력 발전 시스템의 플리커 추정)

  • Van, Tan Loung;Nguyen, Thanh Hai;Kim, Ki-Hong;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.309-318
    • /
    • 2010
  • This paper presents a simulation model based on support vector regression (SVR) for flicker estimation emitted from the wind turbines. For the SVR training, the voltage variation and flicker level are selected as input and output, respectively. Through the off-line training, the relationship between the voltage variation and flicker level is derived. The required amount of data for the flicker measurement is decreased and its proessing time is also reduced. The simulation and experiment results have shown that the flicker estimation is performed accurately.

Frequency/Amplitude Separation Algorithm Using the Higher Order Differential Energy Operator and Its Application (고차의 미분에너지함수를 이용한 주파수 및 진폭성분 추출 알고리즘과 응용)

  • Iem, Byeong-Gwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1498-1502
    • /
    • 2007
  • There have been many different definitions of energy functions as the second statistics of a signal. In this paper, using the higher order differential energy function, we propose an algorithm separating the amplitude and frequency components in a discrete sinusoidal signal. The proposed amplitude and frequency estimation methods have less computational requirement than the existing methods. It also shows large computational advantage over the root mean square (RMS) calculation of a signal. The proposed methods can be used in the detection of abnormal events in signals on the power line. Computer simulations show that proposed frequency estimation method can detect the presence of voltage increase or decrease for a short period of time. Also, the proposed estimation methods have been compared with existing methods in terms of estimation error variance.