• 제목/요약/키워드: oil transformer

검색결과 400건 처리시간 0.026초

변압기유의 유동대전 현상에 관한 연구 (A Study on the Streaming Electrification Phenomena of the Transformer Oil)

  • 강성화;임기조;주상범;김명녕;강도열;김봉협
    • 대한전기학회논문지
    • /
    • 제39권6호
    • /
    • pp.568-576
    • /
    • 1990
  • Recently, streaming electrification in forced oil cooled power transformer has been taken up as a serious problem. In this paper, the charging tendency of various insulation oils, such as mineral oil, polybutene and silicone oil has been measured by means of an injection type charging tendency measuring apparatus under various condition. The experimental data of the dependence of the leakage current on flow velocity and temperature of oil can be explained by considering the flow state such as laminar and turbulent flow. The effect of additives on the charging tendency of mineral oil has been investigated. BTA is regarded as the most effective retardant to electrification of oil among the additives chose for this investigation.

  • PDF

가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가 (The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers)

  • 이병성;송일근;이재봉;한상옥
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

열적열화된 변압기용 절연유의 유전특성 분석 (Dielectric Characteristic Analysis of Thermally Aged Insulating Oil for Transformers)

  • 정종욱;이병성;송일근;박중신;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1594-1596
    • /
    • 2001
  • The purpose of this paper is to provide the fundamental data which can be used for the design of pole transformers. For the purpose, electrical characteristics of aged mineral oil and silicone oil were analyzed by comparing with the results of virgin ones. For the experiment, an oil bath which can keep constant temperature was constructed to thermally deteriorate the specimens. And transformer materials were put together in the bath according to the their ratio in weight in the pole transformer. And the parameters such as relative permittivety, tan$\delta$ and specific resistance were measured. As a results, the permittivity of silicone oil was higher than that of mineral oil, and its decreasing rate with temperature was also higher. In addition, it was found that tan$\delta$ and specific resistance of virgin and aged oil began to differ at similar temperature.

  • PDF

가스센서를 이용한 변압기 절연유중 가스 검출장치의 수소 가스 감지 특성에 관한 연구 (Permeability Study of Membranes for Separation $H_2$ in Oil)

  • 황규현;서호준;이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1845-1847
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the future.

  • PDF

친환경 식물성 절연유의 유중가스 분석 (Dissolved Gas Analysis of Environment-Friendly Vegetable Insulating Oils)

  • 최순호;김관식;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제28권4호
    • /
    • pp.238-243
    • /
    • 2015
  • The vegetable insulating oils are substitute for the mineral oil in power transformer. Vegetable insulating oils has higher flash/fire point and biodegradability than conventional mineral oils. In this paper, we investigated the dissolved gas analysis of vegetable oils. In the experiment, I had to accelerated aging under the same conditions mineral oil and vegetable oils. Accelerated aging proceeded to about 100% of the life of oil-filled transformer. In addition, we performed gas analysis of insulating oil of accelerated aging progress. The experiment results of the five gases was measured with the exception of Hydrogen and Acetylene. The mineral oil and vegetable oils gas is generated in a similar tendency depending on the accelerated aging. As a result, vegetable oils, can be dissolved gas analysis by method such as mineral oil.

변압기 냉각 특성 해석 (Cooling Characteristic Analysis of Transformer's Radiator)

  • 김현재;양시원;김원석;권기영;이민제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1920-1925
    • /
    • 2007
  • A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study, we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design.

  • PDF

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

유동대전(流動帶電)에 미치는 변압기(變壓器) 재질(材質)의 영향(影響) (Effect of Materials on Streaming Electrification in Transformer)

  • 권동진;강창구;곽희로;김재철;이덕철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.170-172
    • /
    • 1990
  • In a large power transformer, an insulating oil is forced to circulate for cooling the heat generated by the losses within the windings and core. When oil flows and rubs against various materials, including insulating paper and steel, electrostatic charges are separated at the interface of the oil and the solid material. This paper considers the polarity and the streaming electrification of the various materials which are used in transformer. As a result of this study, it is confirmed that the leakage current on the solid material, such as paper, is charged negative. On the other hand, the solid material, such as steel, is positively charged.

  • PDF

지능형 유중가스분석법을 이용한 전력용 변압기 관리시스템 개발 (Development of Power Transformer Maintenance System Using Intelligent Dissolved Gas in Oil Analysis)

  • 선종호;김광화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.87-90
    • /
    • 2004
  • This paper describes development of power transformer maintenance system using intelligent dissolved gases in oil analysis. The used gases are acetylene(C2H2), hydrogen(H2), ethylene(C2H4), methane(CH4), ethane(C2H6), carbon monoxide(CO) and carbon dioxide(CO2). The rule and neural network based gas analysis methods are used for artificial intelligent diagnosis. It is indicated that this program is efficient for diagnosis of oil immersed transformers diagnosis from application of gas analysis data of serviced transformer which has local overheating

  • PDF