• Title/Summary/Keyword: observability method

Search Result 86, Processing Time 0.023 seconds

Selection of measurement sets in static structural identification of bridges using observability trees

  • Lozano-Galant, Jose Antonio;Nogal, Maria;Turmo, Jose;Castillo, Enrique
    • Computers and Concrete
    • /
    • v.15 no.5
    • /
    • pp.771-794
    • /
    • 2015
  • This paper proposes an innovative method for selection of measurement sets in static parameter identification of concrete or steel bridges. This method is proved as a systematic tool to address the first steps of Structural System Identification procedures by observability techniques: the selection of adequate measurement sets. The observability trees show graphically how the unknown estimates are successively calculated throughout the recursive process of the observability analysis. The observability trees can be proved as an intuitive and powerful tool for measurement selection in beam bridges that can also be applied in complex structures, such as cable-stayed bridges. Nevertheless, in these structures, the strong link among structural parameters advises to assume a set of simplifications to increase the tree intuitiveness. In addition, a set of guidelines are provided to facilitate the representation of the observability trees in this kind of structures. These guidelines are applied in bridges of growing complexity to explain how the characteristics of the geometry of the structure (e.g. deck inclination, type of pylon-deck connection, or the existence of stay cables) affect the observability trees. The importance of the observability trees is justified by a statistical analysis of measurement sets randomly selected. This study shows that, in the analyzed structure, the probability of selecting an adequate measurement set with a minimum number of measurements at random is practically negligible. Furthermore, even bigger measurement sets might not provide adequate SSI of the unknown parameters. Finally, to show the potential of the observability trees, a large-scale concrete cable-stayed bridge is also analyzed. The comparison with the number of measurements required in the literature shows again the advantages of using the proposed method.

Observability Analysis of a Lever Arm Error for Velocity Matching in Transfer Alignment (전달정렬의 속도정합에 대한 지렛대 거리 오차의 가관측성 분석)

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.276-284
    • /
    • 2013
  • This paper considers the transfer alignment in the inertial navigation system and the observability analysis is performed for velocity matching. The state variable of the Kalman filter is modeled including the lever arm error and the measurement equation is obtained. The SOM(Stripped Observability Matrix) method is used for the observability analysis for various maneuvering conditions of the vehicle, which gives the full state observability condition as a specific maneuver sequence of the vehicle. While the observability analysis of a lever arm effect in the existing papers is mainly performed by simulations, we performed it analytically by the observability analysis method. The analysis result is verified using the computer simulations.

Determination of the nonlinear system observability

  • Hwang, Chun-Sik;Park, Jin-Ok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.957-962
    • /
    • 1990
  • A method to determine nonlinear system observability will be introduced here. For the determination of the deterministic nonlinear system observability two conditions connectedness and univalence, are developed and used. Depending on how the conditions are satisfied, observability is classified in three categories : observability in the strict sense, wide sense, and the unobservable case. Including simple linear and nonlinear system example an underwater acoustical locaization tracking nonlinear system, the bearing-only tracking example is analyzed.

  • PDF

Topological Observability Analysis Using Incidence Matrix in Power Systems (접속행열을 이용한 전력계통 입상학적 가관측성 해석)

  • Seog-Joo Kim;Young-Hyun Moon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.11
    • /
    • pp.769-776
    • /
    • 1987
  • This paper deals with the topological observability analysis and the development of an observable island identification algorithm for state estimation in power systems, by using the incidence matrix and bus voltage grouping. An analogy of the DC power flow method to the DC circuit analysis is introduced, and all the relationships between power flows and phase angles are replaced by the corresponding current-voltage relation. As a result, a set of topological measurement equation expressed in the form of the incidince matrix is derived for the topological analysis, and the observability test is carried out by examining the rand of the measuremint matrix. The integer Gauss elimination method is introduced in the determination of matrix rand, so that the proposed observability test yields a precise observability criterion without any nearly-zero pivot problem encountered in the conventional algorithm. Also, an observable island identification algorithm reduced its computational time in comparision with the conventional algorithms. The proposed algorithms have been tested for sample systems, and their practicability has verified.

Target Motion Analysis for a Passive Sonar System with Observability Enhancing (가관측성 향상을 통한 수동소나체계의 표적기동 분석)

  • 한태곤;송택렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.9-16
    • /
    • 1999
  • As a part of target motion analysis(TMA) with highly noisy bearings-only measurements from a passive sonar system, a nonlinear batch estimator is proposed to provide the initial estimates to a sequential estimator called the modified gain extended Kalman filter(MGEKF). Based on the system observability analysis of passive target tracking, a practical and effective method is suggested to determine the observer maneuvers for improved TMA performance through system observability enhancing. Also suggested is a method to determine observer location for enhanced system observability at the initial phase of TMA from various engagement boundaries which represent the relationship between observer-target relative geometrical data and system observability. The proposed TMA methods are tested by a series of computer simulation runs.

  • PDF

Optimal Placement of the Phasor Measurement Units in Power System (전력계통의 페이저 측정기 최적배치)

  • Kim, Jae-Hun;Jo, Gi-Seon;Kim, Hoi-Chul;Shin, Jung-Rin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

A Multi-objective Placement of Phasor Measurement Units Considering Observability and Measurement Redundancy using Firefly Algorithm

  • Arul jeyaraj, K.;Rajasekaran, V.;Nandha kumar, S.K.;Chandrasekaran, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.474-486
    • /
    • 2015
  • This paper proposes a multi-objective optimal placement method of Phasor Measurement Units (PMUs) in large electric transmission systems. It is proposed for minimizing the number of PMUs for complete system observability and maximizing measurement redundancy of the buses, simultaneously. The measurement redundancy of the bus indicates that number of times a bus is able to monitor more than once by PMUs set. A high level of measurement redundancy can maximize the system observability and it is required for a reliable power system state estimation. Therefore, simultaneous optimizations of the two conflicting objectives are performed using a binary coded firefly algorithm. The complete observability of the power system is first prepared and then, single line loss contingency condition is added to the main model. The practical measurement limitation of PMUs is also considered. The efficiency of the proposed method is validated on IEEE 14, 30, 57 and 118 bus test systems and a real and large- scale Polish 2383 bus system. The valuable approach of firefly algorithm is demonstrated in finding the optimal number of PMUs and their locations by comparing its performance with earlier works.

A Balanced Model Reduction for Fuzzy Systems with Time Varying Delay

  • Yoo, Seog-Hwan;Park, Byung-Jae
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • This paper deals with a balanced model reduction for T-S(Takagi-Sugeno) fuzzy systems with time varying state delay. We define a generalized controllability gramian and a generalized observability gramian for a stable T-S fuzzy delayed systems. We obtain a balanced state space realization using the generalized controllability and observability gramian and obtain a reduced model by truncating states from the balanced state space realization. We also present an upper bound of the approximation error. The generalized controllability gramian and observability gramian can be computed from solutions of linear matrix inequalities. We demonstrate the efficacy of the suggested method by illustrating a numerical example.

Study on the Observability of a Calibration System for a Parallel Tilting Table with Measuerment Operator (측정연산자에 의한 병렬기구 틸팅 테이블의 관측성에 관한 연구)

  • Park Kun Woo;Lee Min Ki;Kim Tae Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.795-803
    • /
    • 2005
  • This paper studies the observability of calibration system with a measurement operator. The calibration system needs a simple digital indicator to measure the mobile table movements with respect to the MC coordinate. However, it yields the concern about the poor parameter observability due to measuring only a part of the movements. We uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of an observation matrix. The number of identifiable parameter is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a 6-axis MC with parallel tilting table and the calibration results are presented. These results verify that all necessary kinematic parameters are observable and the calibration system has robustness to the noise using optimal calibration configurations.

Study on the Observability of Calibration System with a Constraint Oprerator (구속연산자에 의한 보정 시스템의 관측성에 관한 연구)

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.647-655
    • /
    • 2003
  • This paper studies the observability of calibration system with a constraint movement by a constraint operator. The calibration system with the constraint movement need only simple sensing device to check whether the constraint movements are completed within an established range. However, it yields the concern about the poor parameter observability due to the constraint movements. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters are examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a parallel typed machining center and the calibration results are presented. These results verify that the calibration system with low-cost indicators and simple planar table is accurate as well as reliable.