• Title/Summary/Keyword: number of sensors

Search Result 1,024, Processing Time 0.026 seconds

Analysis of BWIM Signal Variation Due to Different Vehicle Travelling Conditions Using Field Measurement and Numerical Analysis (수치해석 및 현장계측을 통한 차량주행조건에 따른 BWIM 신호 변화 분석)

  • Lee, Jung-Whee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.79-85
    • /
    • 2011
  • Bridge Weigh-in-Motion(BWIM) system calculates a travelling vehicle's weight without interruption of traffic flow by analyzing the signals that are acquired from various sensors installed in the bridge. BWIM system or data accumulated from the BWIM system can be utilized to development of updated live load model for highway bridge design, fatigue load model for estimation of remaining life of bridges, etc. Field test with moving trucks including various load cases should be performed to guarantee successful development of precise BWIM system. In this paper, a numerical simulation technique is adopted as an alternative or supplement to the vehicle traveling test that is indispensible but expensive in time and budget. The constructed numerical model is validated by comparison experimentally measured signal with numerically generated signal. Also vehicles with various dynamic characteristics and travelling conditions are considered in numerical simulation to investigate the variation of bridge responses. Considered parameters in the numerical study are vehicle velocity, natural frequency of the vehicle, height of entry bump, and lateral position of the vehicle. By analyzing the results, it is revealed that the lateral position and natural frequency of the vehicle should be considered to increase precision of developing BWIM system. Since generation of vehicle travelling signal by the numerical simulation technique costs much less than field test, a large number of test parameters can effectively be considered to validate the developed BWIM algorithm. Also, when artificial neural network technique is applied, voluminous data set required for training and testing of the neural network can be prepared by numerical generation. Consequently, proposed numerical simulation technique may contribute to improve precision and performance of BWIM systems.

Implementation of IoT-based carbon-neutral modular smart greenhouse (IoT 기반 탄소중립 모듈형 스마트 온실 구현)

  • Seok-Keun Park;Kil-Su Han;Min-Soon Lee;Changsun Shin
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.36-45
    • /
    • 2023
  • Recently, in digital agriculture, the types and utilization of greenhouses based on IoT are spreading, and greenhouses are being modernized, enlarged, and even factoryized using smart technology. However, a specific standardization plan has not been proposed according to the equipment for data collection in the smart greenhouse and the size or shape of the greenhouse. In other words, there is a lack of standard data for facility equipment, such as the type and number of sensors and equipment according to the size of the greenhouse, the type of greenhouse construction film and materials suitable for crops and carbon neutrality. Therefore, in this study, the suitability of the implementation, installation and quantity of IoT equipment for data collection was tested, and some standard technologies were presented through the implementation of data collection and communication methods. In addition, impact strength, tensile, tear, elongation, light transmittance, and lifespan issues for PE, PVC, and EVA, which account for about 90% of existing greenhouses, were presented, and the shape, size, and environmental problems of greenhouses made of films were presented. presented in the text. In this research paper, a standardized carbon-neutral modular smart greenhouse using nano-material film was implemented as a solution to environmental problems such as greenhouse size, farm crop type, greenhouse lifespan, and film, and its performance with existing greenhouses was analyzed and presented. Through this, we propose a modularized greenhouse that can be expanded or reduced freely without distinction in the size of the greenhouse or the shape of farmhouse crops, and the lifespan is extended and standardized. Finally, the average characteristics of greenhouses using existing PE, PVC, and EVA films and the characteristics of greenhouses using new carbon-neutral nanomaterials are compared and reviewed, and a plan to implement an expandable IoT greenhouse that supports carbon neutrality is proposed.

Effect of Air Humidity and Water Content of Medium on the Growth and Physiological Disorder of Paprika in Summer Hydroponics (여름철 착색단고추 수경재배 시 공중습도 및 배지함수량이 생육 및 과실의 생리장해에 미치는 영향)

  • Rhee, Han-Cheol;Seo, Tae-Cheol;Choi, Gyoeng-Lee;Roh, Mi-Young;Cho, Myeung-Whan
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.305-310
    • /
    • 2010
  • This study was carried out to investigate the effect of air humidity and water content of medium on the growth and physiological disorder of paprika in summer hydroponics. Treatments were composed of air humidity of control (over 90%) and dehumidification (low 90%) and water content of 80% and 50%. Time domain reflectometry (TDR) sensors and dehumidifier were used in a drip irrigation system and control system of air humidity, respectively. The early growth of paprika was not affected by air humidity but increased by high water content (80%) of medium. Mean fruit weight was reduced at high air humidity and low water content (50%) of medium, but the fruit number per plant and yield were increased at low air humidity. The incidence of brown fruit stem increased with increasing air humidity and water content of medium. Rate of blossom end rot increased in the low water content medium compared with the high water content medium. The nitrogen (N) was higher content in brown fruit stem than normal stem, but calcium (Ca) was lower.

Design of Analog CMOS Vision Chip for Edge Detection with Low Power Consumption (저전력 아날로그 CMOS 윤곽검출 시각칩의 설계)

  • Kim, Jung-Hwan;Park, Jong-Ho;Suh, Sung-Ho;Lee, Min-Ho;Shin, Jang-Kyoo;Nam, Ki-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.231-240
    • /
    • 2003
  • The problem of power consumption and the limitation of a chip area should be considered when the pixel number of the edge detection circuit increases to fabricate a vision chip for edge detection with high resolution. The numeric increment of the unit circuit causes power consumption to increase and require a larger chip area. An increment of power consumption and a limitation of chip area with several ten milli-meters square supplied by the CMOS foundry company restrict the pixel numbers of the edge detection circuit. In this paper, we proposed a electronic switch to minimize the power consumption owing to the numeric increment of the edge detection circuit to realize a vision chip for edge detection with high resolution. We also applied a method by which photodetector and edge detection circuit are separated to implement a vision chip with a higher resolution. The photodetector circuit with $128{\times}128$ pixels uses a common edge detection circuit with $1{\times}128$ pixels so that resolution was improved at the same chip area. The chip size is $4mm{\times}4mm$ and the power consumption was confirmed to be about 20mW using SPICE.

Fabrication of TiO2/polyelectrolyte thin film for a methyl mercaptan gas sensor (메칠멜캅탄 가스센서용 TiO2/전해질폴리머 박막 제조)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lee, Mi-Jai;Kim, Sei-Ki;Lim, Tae-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.221-226
    • /
    • 2010
  • Quartz crystal microbalance (QCM) gas sensor to detect methyl mercaptan ($CH_3SH$) gas was fabricated by depositing $TiO_2$ nanoparticles and polyelectrolyte on the electrode of QCM. The $TiO_2$/poly(sodium 4-styrenesulfonate) (PSS) thin film fabricated by a layer-by-layer self-assembly (LBL-SA) method showed a high surface area and increased the sensitivity of gas sensor. When the QCM sensors coated with triethanolamine (TEA) or ($TiO_2$/PSS) were exposed to methyl mercaptan gas (1.0 ppm), the frequency shifts of QCM with TEA casting film and $TiO_2$/PSS thin film were ca. 9 Hz and ca. 24 Hz, respectively. As the bilayer number of ($TiO_2$/PSS) increased, the frequency shift of QCM sensor with ($TiO_2$/PSS) thin film was gradually increased. In addition, the frequency shift of QCM sensor was gradually increased as the concentration of methyl mercaptan gas increased from 0.5 ppm to 2.0 ppm. In this study, the surface morphology and sensor property of QCM sensor coated with ($TiO_2$/PSS) thin film were measured.

Review Paper for Characterization of Photoionization Detector-Direct Reading Monitors (산업현장에 활용되는 PID 직독식장비의 특성 고찰)

  • Sungho Kim;Hae Dong Park;Eunsong Hwang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.93-102
    • /
    • 2023
  • Objectives: With the evolution of direct reading sensors, it is possible to monitor several substances through telecommunication. However, there are some limitations on the use of direct reading technologies in the Occupational Safety and Health Act in South Korea, which only applies to detector tubes, noise, heat, and carbon monoxides. The number of chemicals and their amount of use have been continuously increasing in South Korea. The Ministry of Employment and Labor (MoEL) has concerns about worker's health because exposure is only covered for about 1.2% of all distributed chemicals. Using a direct reading monitor with photoionization detectors (PID-DRMs), gases and vapors chemicals can be measured. Based on the data, business owners are able to create corrective strategies, provide better working routines, and select correct respiratory equipment. PID-DRMs are less expensive and easier to handle for an owner voluntarily controlling chemicals emitted in the workplace. However, there are several limitations on using these PID-DRMs to the degree that the MoEL has not been able to select a legal monitor. The aim of this study was to review previous studies related to PID-DRMs and identify the characterization and limitation on PID-DRMs. Methods: To search for related studies on PID-DRMs, key words were used including direct reading monitors/instruments and/or photoionization detectors. Through that, four domestic and 15 international studies were reviewed. Results: Studies on PID-DRMs were conducted by chamber (enclosed, dynamic, walk-in) and in the field (experimental environment, actual environment). The concentration of PID-DRMs and charcoal tubes were compared for a single substance or mixture, or within the PID-DRMs. There was a high correlation between the two concentrations, but it did not meet the accuracy criteria (95% confidence interval, within 25%) of the NIOSH technical report (2012). In addition, differences in measured values occurred according to environmental factors (temperature, humidity) and high concentration, and concentration values tended to be underestimated due to contamination of the sensor. As a way to improve the accuracy of PID concentration, it was proposed to use correction factors, charcoal tube-based correction factors, or to calibrate the PID-DRMs in the same environment as the workplace. Conclusions: PID-DRMs can likely be used by business owners for the purpose of voluntarily managing the workplace environment, and it is expected that it will be possible to use them as legal equipment if a PID sensor can be upgraded and the limitations of the sensor (temperature, humidity, high concentration evaluation, sensor pollution) can be overcome in the near future.

A Case Study on Field Campaign-Based Absolute Radiometric Calibration of the CAS500-1 Using Radiometric Tarp (Radiometric Tarp를 이용한 현장관측 기반의 차세대중형위성 1호 절대복사보정 사례 연구)

  • Woojin Jeon;Jong-Min Yeom;Jae-Heon Jung;Kyoung-Wook Jin;Kyung-Soo Han
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1273-1281
    • /
    • 2023
  • Absolute radiometric calibration is a crucial process in converting the electromagnetic signals obtained from satellite sensors into physical quantities. It is performed to enhance the accuracy of satellite data, facilitate comparison and integration with other satellite datasets, and address changes in sensor characteristics over time or due to environmental conditions. In this study, field campaigns were conducted to perform vicarious calibration for the multispectral channels of the CAS500-1. Two valid field observations were obtained under clear-sky conditions, and the top-of-atmosphere (TOA) radiance was simulated using the MODerate resolution atmospheric TRANsmission 6 (MODTRAN 6) radiative transfer model. While a linear relationship was observed between the simulated TOA radiance of tarps and CAS500-1 digital numbers(DN), challenges such as a wide field of view and saturation in CAS500-1 imagery suggest the need for future refinement of the calibration coefficients. Nevertheless, this study represents the first attempt at absolute radiometric calibration for CAS500-1. Despite the challenges, it provides valuable insights for future research aiming to determine reliable coefficients for enhanced accuracy in CAS500-1's absolute radiometric calibration.

Development of Realtime Temperature & Humidity Logging and Monitoring System using Ubiquitous Sensor Network (유비쿼터스 센서 네트워크를 이용한 실시간 온.습도 기록 및 모니터링 시스템 개발)

  • Cheon, Seong-Sim;Kim, Jung-Ja;Won, Yong-Gwan;Pham, Hai Trieu
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.96-105
    • /
    • 2011
  • Ubiquitos sensor network(USN) is a technology which is widely used in our life. This paper introduces an example of design and implementation for a system which is based on the USN technology and can provide an efficient management tool for a space that should be precisely controlled for a certain range of uniformity in temperature and humidity. This introduced system builds a wireless sensor network using a number of sensor modules that are equipped with temperature and humidity sensors, and collects temperature and humidity information in real-time while simultaneously providing a method for monitoring the status of temperature and humidity by the graphical user interface. Also, the system will give a warning signal if the monitored values are differ from the pre-specified values of temperature and humidity for each sensor module more than a certain amount of tolerance. This temperature and humidity logging and monitoring system can perform better management for the space easily and efficiently by automating the existing manual method for data collection and management. Furthermore, using the stored data, it can make possible to perform post-analysis on the problems caused by temperature and humidity and to obtain information for environmental enhancement for the space.

IoT Security Channel Design Using a Chaotic System Synchronized by Key Value (키값 동기된 혼돈계를 이용한 IoT의 보안채널 설계)

  • Yim, Geo-Su
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.981-986
    • /
    • 2020
  • The Internet of Things refers to a space-of-things connection network configured to allow things with built-in sensors and communication functions to interact with people and other things, regardless of the restriction of place or time.IoT is a network developed for the purpose of services for human convenience, but the scope of its use is expanding across industries such as power transmission, energy management, and factory automation. However, the communication protocol of IoT, MQTT, is a lightweight message transmission protocol based on the push technology and has a security vulnerability, and this suggests that there are risks such as personal information infringement or industrial information leakage. To solve this problem, we designed a synchronous MQTT security channel that creates a secure channel by using the characteristic that different chaotic dynamical systems are synchronized with arbitrary values in the lightweight message transmission MQTT protocol. The communication channel we designed is a method of transmitting information to the noise channel by using characteristics such as random number similarity of chaotic signals, sensitivity to initial value, and reproducibility of signals. The encryption method synchronized with the proposed key value is a method optimized for the lightweight message transmission protocol, and if applied to the MQTT of IoT, it is believed to be effective in creating a secure channel.

Effect of Water Content in Substrates as According to Growth Stage on the Growth and Yield of Paprika in Summer Hydroponics (여름철 파프리카 수경재배 시 생육단계별 코이어 배지함수량이 생육과 수량에 미치는 영향)

  • Rhee, Han-Cheol;Seo, Tae-Cheol;Choi, Gyoeng-Lee;Roh, Mi-Young;Cho, Myeung-Whan;Kim, Young-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.258-262
    • /
    • 2011
  • This study was carried out to investigate the effect the water content in substrates as according to growth stage on the growth and yield of paprika in summer hydroponics. Treatments of I, II and III were composed of 55-65-60, 50-60-55 and 45-55-50 % in water contents of growth stages, respectively. Time domain reflectometry (TDR) sensors were used in a drip irrigation system. The early growth of paprika was increased by high medium water content of treatment I. Mean fruit weight was not affected by medium water content, but the fruit number per plant and yield were increased at high medium water content of treatment I. The yield of treatment I was higher than that of treatment II and III. The incidence of brown stem fruit, blossom end rot and sunburn was decreased with increasing water content of medium. Occurred in the low water content of medium. The nitrogen (N) was higher content in brown stem fruit than normal stem, but mineral contents such as potassium (K), calcium (Ca), magnesium (Mg) etc. were not affected.