• Title/Summary/Keyword: normalized k

Search Result 2,395, Processing Time 0.038 seconds

An Improvement of Closed-Form Formula for Mutual Impedance Computation

  • Son, Trinh-Van;Hwang, Keum Cheol;Park, Joon-Young;Kim, Seon-Joo;Shin, Jae-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.4
    • /
    • pp.240-244
    • /
    • 2013
  • In this paper, we present an improvement of a closed-form formula for mutual impedance computation. Depending on the center-to-center spacing between two rectangular microstrip patch antennas, the mutual impedance formula is separated into two parts. The formula based on synthetic asymptote and variable separation is utilized for spacings of more than 0.5 ${\lambda}_0$. When the spacing is less than 0.5 ${\lambda}_0$, an approximate formula is proposed to improve the computation for closely spaced elements. Simulation results are compared to computational results of mutual impedances and mutual coupling coefficients as functions of normalized center-to-center spacing in both E- and H-plane coupling configurations. A good agreement between simulation and computation is achieved.

Functional evaluation of orthopedic and orthodontic treatment in a patient with unilateral posterior crossbite and facial asymmetry

  • Kwak, Yoon-Young;Jang, Insan;Choi, Dong-Soon;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.44 no.3
    • /
    • pp.143-153
    • /
    • 2014
  • An 8-years old boy with facial asymmetry and unilateral posterior crossbite on the left side received orthopedic and orthodontic treatment. During the first phase of treatment, the narrow maxillary arch was expanded using an acrylic plate. Then, the acrylic plate was used as a bite block with occlusal indentations from the construction bite that was obtained with the incisors in a coincident dental midline. After the position of the mandible was stabilized, the second phase of orthodontic treatment was initiated using fixed appliances for detailing of the occlusion. Skeletal symmetry, ideal occlusion, and coincident dental midlines were thus achieved. Functionally, occlusal force balance and masticatory muscle activity were improved, and the chewing patterns were normalized.

A Study on the Operational Environment of Railway Signalling System (철도 신호시스템 환경요구사양 및 시험사양에 관한 연구)

  • Joung, E.J.;Hwang, J.G.;Lee, J.W.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1384-1386
    • /
    • 2000
  • To determine operational requirement, the environmental condition for an equipment must be investigated, and to certify equipment's normalized operation, appropriate test must be carried out under the considered environmental condition. The actual environmental conditions to which equipment is likely to be exposed are normally complex and will comprise a number of environmental factors and corresponding parameters, When defining the environmental conditions for a certain application it is, therefore, necessary to list the factors involved and select the appropriate severity. The operational environment is structured in two separate such as requirements, guidance and test specifications. For the preparation to determine operational requirement, operational environment of railway signalling equipment is investigated.

  • PDF

A Case of Amisulpride Induced QT Prolongation (Amisulpride 중독과 QT 간격 연장 1례)

  • Lee Choung Ah;Park Hyeon Soo;Min Young Gi;Kim Gi Woon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.2
    • /
    • pp.135-138
    • /
    • 2005
  • Amisulpride is a newly developed atypical antipsychotic agent effective in treating the positive and negative symptom of schizophrenia. Over-dose of amisulpride can cause hypocalcemia and thus may lead to QT prolongation. We report a case of hypocalcemia and QT prolongation. The QT prolongation was normalized after calcium supplement.

  • PDF

Takotsubo Cardiomyopathy Associated with Guillain-Barré Syndrome (길랑-바레 증후군에서 발생한 Takotsubo 심근병)

  • Kang, Chul-Hoo;Oh, Jung Hwan;Song, Sook Keun;Kang, Sa-Yoon
    • Annals of Clinical Neurophysiology
    • /
    • v.17 no.2
    • /
    • pp.73-75
    • /
    • 2015
  • A 69-year-old woman presented with a progressive limb weakness. Both clinical and neurophysiological findings were consistent with diagnosis of Guillain-$Barr{\acute{e}}$ syndrome (GBS). Two days after admission, the patient suffered from an acute coronary syndrome without stenosis at coronary arteriography. Echocardiography revealed left ventricular inferior wall and apical akinesia and decreased ejection fraction. A diagnosis of Takotsubo cardiomyopathy was then made. Left ventricular dysfunction and electrocardiography normalized within one month. Takotsubo cardiomyopathy can be developed as a complication of GBS.

Using generalized regression neural network (GRNN) for mechanical strength prediction of lightweight mortar

  • Razavi, S.V.;Jumaat, M.Z.;Ahmed H., E.S.;Mohammadi, P.
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.379-390
    • /
    • 2012
  • In this paper, the mechanical strength of different lightweight mortars made with 0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95 and 100 percentage of scoria instead of sand and 0.55 water-cement ratio and 350 $kg/m^3$ cement content is investigated. The experimental result showed 7.9%, 16.7% and 49% decrease in compressive strength, tensile strength and mortar density, respectively, by using 100% scoria instead of sand in the mortar. The normalized compressive and tensile strength data are applied for artificial neural network (ANN) generation using generalized regression neural network (GRNN). Totally, 90 experimental data were selected randomly and applied to find the best network with minimum mean square error (MSE) and maximum correlation of determination. The created GRNN with 2 input layers, 2 output layers and a network spread of 0.1 had minimum MSE close to 0 and maximum correlation of determination close to 1.

Analysis of On-Line Partial Discharge Trend in High Voltage Motors (고압전동기 운전중 부분방전 추이 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Chung-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1472-1473
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) measurements were peformed with turbine generator analyzer(TGA) in two high voltage motors(rated 6.6 kV). These high voltage motors were installed with 80 pF capacitive couplers at the terminal box. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude (Qm). The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in stator windings of high voltage motors.

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

Characteristics Analysis Eddy Current Sensor Using by Numerical Analysis (수치해석을 이용한 와전류센서의 특성해석)

  • Choi, Duck-Su;Lee, Hyang-Beom;Na, Eun-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1000-1002
    • /
    • 2003
  • The characteristics of eddy current sensor has been analyzed by using numerical analysis which is performed by modeling eddy current sensor and analytic object into three-dimension axis-symmetry in this paper. The eddy current sensor is modeled as cylindrical shape with variation of inside and outside diameter and frequency range between 1[kHz] and 1[MHa] for numerical analysis. The value of impendence on eddy current sensor depending on frequency variation was calculated through numerical analysis. The characteristics of eddy current sensor can be studied by normalized impendence which is gained from the calculated impendence. Therefore, sensitivity of eddy current sensor depending on frequency, inside and outside diameter can be known by investigating diameter of half circle impendence and its locus.

  • PDF

Simplified Machine Diagnosis Techniques by Impact Vibration using n-th Moment of Absolute Deterioration Factor

  • Takeyasu, Kazuhiro;Amemiya, Takashi;Tanaka, Jumpei;Masuda, Shiro
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.1
    • /
    • pp.68-74
    • /
    • 2005
  • Among many dimensional and dimensionless amplitude parameters, kurtosis (4-th normalized moment of probability density function) is generally regarded as a sensitive good parameter for machine diagnosis. However, higher order moment may be supposed to be much more sensitive. Bicoherence is an absolute deterioration factor whose range is 1 to 0. The theoretical value of n-th moment divided by n-th moment calculated by measured data would behave in the same way. We propose a simplified calculation method for an absolute index of n-th moment and name this as simplified absolute index of n-th moment. Some favorable results are obtained.