• Title/Summary/Keyword: normalized k

Search Result 2,395, Processing Time 0.029 seconds

Accuracy evaluation of near-surface air temperature from ERA-Interim reanalysis and satellite-based data according to elevation

  • Ryu, Jae-Hyun;Han, Kyung-Soo;Park, Eun-Bin
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.6
    • /
    • pp.595-600
    • /
    • 2013
  • In order to spatially interpolate the near-surface temperature (Ta) values, satellite and reanalysis methods were used from previous studies. Accuracy of reanalysis Ta was generally better than that of satellite-based Ta, but spatial resolution of reanalysis Ta was large to use at local scale studies. Our purpose is to evaluate accuracy of reanalysis Ta and satellite-based Ta according to elevation from April 2011 to March 2012 in Northeast Asia that includes various topographic features. In this study, we used reanalysis data that is ERA-Interim produced by European Centre for Medium-Range Weather Forecasts (ECMWF), and estimated satellite-based Ta using Digital Elevation Meter (DEM), Normalized Difference Vegetation Index (NDVI), difference between brightness temperature of $11{\mu}m$ and $12{\mu}m$, and Land Surface Temperature (LST) data. The DEM data was used as auxiliary data, and observed Ta at 470 meteorological stations was used in order to evaluate accuracy. We confirmed that the accuracy of satellite-based Ta was less accurate than that of ERA-Interim Ta for total data. Results of analyzing according to elevation that was divided nine cases, ERA-Interim Ta showed higher accurate than satellite-based Ta at the low elevation (less than 500 m). However, satellite-based Ta was more accurate than ERA-Interim Ta at the higher elevation from 500 to 3500 m. Also, the width of the upper and lower quartile appeared largely from 2500 to 3500 m. It is clear from these results that ERA-Interim Ta do not consider elevation because of large spatial resolution. Therefore, satellite-based Ta was more effective than ERA-Interim Ta in the regions that is range from 500 m to 3500 m, and satellite-based Ta was recommended at a region of above 2500 m.

Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms (수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 -)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Yeon, Jun Oh;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

Effects of Pretreatment of Serotonin Synthesis Inhibitor p-chlorophenylalanine on Lipopolysaccharide-induced Anorexia in Rats

  • Park, So-Young;Kim, Byung-Suck;Back, Seoung-Sook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.133-138
    • /
    • 2001
  • In the present study, we investigated the effect of pretreatment of p-chlorophenylalanine (PCPA), inhibitor of serotonin synthesis, on lipopolysaccharide (LPS)-induced anorexia in rats. First of all, effects of PCPA injection on food intake and body weight in rats were investigated. During 4 days of PCPA injection (300 mg/kg BW once a day), food intake was decreased by 33% and daily gain in body weight was inhibited compared with controls. Twenty-four hours after last PCPA injection, food intake and gain in body weight returned toward almost normal. Pair-feeding to PCPA (PCPAP) injection revealed that body weight of rats in PCPA group was not different from rats in PCPAP groups. To quantify the effects of LPS on food intake and body weight, we administered varying doses $(10,\;100,\;500\;{\mu}g/kg\;BW)$ of LPS to rats. LPS induced a reduction of food intake and weight loss in a dose dependent manner compared with controls. To evaluate the effects of PCPA pretreatment on LPS injection, rats were treated with PCPA for 4 days (300 mg/kg BW once a day), which was followed by LPS injection for 2 days $(500\;{\mu}g/kg\;BW\;once\;a\;day)$ (PCPA+LPS group), while rats in LPS group had injections with normal saline instead of PCPA for 4 days, which was followed by LPS administration. Rats in control group received 0.9% NaCl for 6 days. LPS decreased food intake by 80% and inhibited gain in body weight, while PCPA pretreated rats showed normalized food intake and gain in weight during the days of LPS injections compared with controls. In conclusion, pretreatment of PCPA prevented LPS-induced anorexia.

  • PDF

The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator (선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰)

  • Lim CK.;Kim HN.;Song KW.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

Effect of Ionic Copper Toxicity on the Growth of Green Alga, Selenastrum capricornutum

  • Kim, Mi-Kyung;Ralph E. H. Smith
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.211-216
    • /
    • 2001
  • The growth of Selenastrum capricornutum in culture was investigated as a function of ionic copper concentrations to verify the toxicity and physiological variation. In a $Cu^{++}$ excess culture (E: $Cu^{++}$ of $130{\mu}g/l$), the growth rate (K)(0.32) was lower than that of the control culture (C: $Cu^{++}$ of $0.065{\mu}g/l$) (0.61) after 8 days and the exponential growth rate ($R_E$) was also found to be lower in culture E (1.1) than culture C (2.9). On the contrary, the K of S. capricornutum in trace $Cu^{++}$ culture ($T_1$ and $T_2$, 0.72) after 6 days tended to be more increased than culture C (0.68). From 8 to 14 days of culture, the amounts of chlorophyllls a and b were increased in culture C (chlorophyll a, $106->126{\mu}g/g$ dry wt; chlorophyll b, $158->208{\mu}g/g$ dry wt; chlorophyll b were decreased in culture E (chlorophyll a, $309->235{\mu}g/g$ dry wt; chlorophyll b, $405->352{\mu}g/g$ dry wt). The amounts of chlorophylls in ionic copper trace culture ($T_1$ and $T_2$) [(chl a/b) of $T_1$: $384/620\;{\mu}g/g$ dry wt; (chl a/b) of $T^2$:$320/467{\mu}g/g$ dry wt] were increased more than the culture C($260/387{\mu}g/g$ dry wt). Howeveer, when photosynthetic rates were normalized to the dry weight of algae, the control culture continued to showed higher values than the treated culture ($T_1$). An appropriate amount of ionic copper ($T_1:\;26\;{\mu}g/l$) stimulated the grwoth of S. capricornutum than the ionic copper content of $13\;{\mu}g/l$ ($T_2$), while the excess amount of ionic copper ($130\;{\mu}g/l$) resulted in the highest toxicity to the growth of S. capricornutum.

  • PDF

Nonlinear analysis of concrete-filled steel composite columns subjected to axial loading

  • Bahrami, Alireza;Badaruzzamana, Wan Hamidon Wan;Osmanb, Siti Aminah
    • Structural Engineering and Mechanics
    • /
    • v.39 no.3
    • /
    • pp.383-398
    • /
    • 2011
  • This paper investigates the nonlinear analysis of concrete-filled steel composite columns subjected to axial loading to predict the ultimate load capacity and behaviour of the columns. Finite element software LUSAS is used to conduct the nonlinear analyses. The accuracy of the finite element modelling is verified by comparing the result with the corresponding experimental result reported by other researchers. Nonlinear analyses are done to study and develop different shapes and number of cold-formed steel sheeting stiffeners with various thicknesses of cold-formed steel sheets. Effects of the parameters on the ultimate axial load capacity and ductility of the concrete-filled steel composite columns are examined. Effects of variables such as concrete compressive strength $f_c$ and cold-formed steel sheet yield stress $f_{yp}$ on the ultimate axial load capacity of the columns are also investigated. The results are shown in the form of axial load-normalized axial shortening plots. It is concluded from the study that the ultimate axial load capacity and behaviour of the concrete-filled steel composite columns can be accurately predicted by the proposed finite element modelling. Results in this study demonstrate that the ultimate axial load capacity and ductility of the columns are affected with various thicknesses of steel sheets and different shapes and number of stiffeners. Also, compressive strength $f_c$ of the concrete and yield stress $f_{yp}$ of the cold-formed steel sheet influence the performance of the columns significantly.

cDNA Microarray Analysis of Differential Gene Expression in Boar Testes during the Prepubertal Period

  • Lee, Dong-Mok;Lee, Ki-Ho;Choi, Jin Ho;Hyun, Jin Hee;Lee, Eun Ju;Bajracharya, Prati;Lee, Yong Seok;Chang, Jongsoo;Chung, Chung Soo;Choi, Inho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.8
    • /
    • pp.1091-1101
    • /
    • 2009
  • In an attempt to understand the biochemical mechanism for the synthesis of the anabolic steroid, 19-nortestosterone, produced by prepubertal boar testes and its physiological role, normalized complementary DNA (cDNA) from boar testes was generated. DNA sequencing of 2,016 randomly selected clones yielded 794,116 base pairs of high quality nucleotide sequence. Computer-assisted assembly of the nucleotide sequence of each clone resulted in 423 contigs and 403 singletons including several genes for steroidogenic enzymes and molecules related to steroid metabolism. Analysis of gene expression pattern by use of the presently-fabricated cDNA microarray identified a number of genes that were differentially expressed during the postnatal development period in boar testes. Two genes of unknown function were identified to be highly expressed in the testis of 2-weeks-old neonatal boar. In addition, the sequencing of open reading frames of these genes revealed their homology with human alpha hemoglobin and Homo sapiens hypothetical LOC643669, transcript variant 1. Moreover, the transcripts of these genes were also detected in porcine muscle and adipocytes, in addition to Leydig cells of pigs.

A CHARACTERIZATION OF WEIGHTED BERGMAN-PRIVALOV SPACES ON THE UNIT BALL OF Cn

  • Matsugu, Yasuo;Miyazawa, Jun;Ueki, Sei-Ichiro
    • Journal of the Korean Mathematical Society
    • /
    • v.39 no.5
    • /
    • pp.783-800
    • /
    • 2002
  • Let B denote the unit ball in $C^n$, and ν the normalized Lebesgue measure on B. For $\alpha$ > -1, define $dv_\alpha$(z) = $c_\alpha$$(1-\midz\mid^2)^{\alpha}$dν(z), z $\in$ B. Here $c_\alpha$ is a positive constant such that $v_\alpha$(B) = 1. Let H(B) denote the space of all holomorphic functions in B. For $p\geq1$, define the Bergman-Privalov space $(AN)^{p}(v_\alpha)$ by $(AN)^{p}(v_\alpha)$ = ${f\inH(B)$ : $\int_B{log(1+\midf\mid)}^pdv_\alpha\;<\;\infty}$ In this paper we prove that a function $f\inH(B)$ is in $(AN)^{p}$$(v_\alpha)$ if and only if $(1+\midf\mid)^{-2}{log(1+\midf\mid)}^{p-2}\mid\nablaf\mid^2\;\epsilon\;L^1(v_\alpha)$ in the case 1<p<$\infty$, or $(1+\midf\mid)^{-2}\midf\mid^{-1}\mid{\nabla}f\mid^2\;\epsilon\;L^1(v_\alpha)$ in the case p = 1, where $nabla$f is the gradient of f with respect to the Bergman metric on B. This is an analogous result to the characterization of the Hardy spaces by M. Stoll [18] and that of the Bergman spaces by C. Ouyang-W. Yang-R. Zhao [13].

Performance Comparison of Wave Information Retrieval Algorithms Based on 3D Image Analysis Using VTS Sensor (VTS 센서를 이용한 3D영상 분석에 기초한 파랑 정보 추출 알고리즘 성능 비교)

  • Ryu, Joong-seon;Lim, Dong-hee;Kim, Jin-soo;Lee, Byung-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.519-526
    • /
    • 2016
  • As marine accidents happen frequently, it is required to establish a marine traffic monitoring system, which is designed to improve the safety and efficiency of navigation in VTS (Vessel Traffic Service). For this aim, recently, X-band marine radar is used for extracting the sea surface information and, it is necessary to retrieve wave information correctly and provide for the safe and efficient movement of vessel traffic within the VTS area. In this paper, three different current estimation algorithms including the classical least-squares (LS) fitting, a modified iterative least-square fitting routine and a normalized scalar product of variable current velocities are compared with buoy data and then, the iterative least-square method is modified to estimate wave information by improving the initial current velocity. Through several simulations with radar signals, it is shown that the proposed method is effective in retrieving the wave information compared to the conventional methods.

Quality Control Probes for Spot-Uniformity and Quantitative Analysis of Oligonucleotide Array

  • Jang, Hyun-Jung;Cho, Mong;Kim, Hyung-Hoi;Kim, Cheol-Min;Park, Hee-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.7
    • /
    • pp.658-665
    • /
    • 2009
  • Quality control QC for spot-uniformity is a critical point in fabricating an oligonucleotide array, and quantification of targets is very important in array analysis. We developed two new types of QC probes as a means of confirming the quality of the uniformity of attached probes and the quantification of targets. We compared the signal intensities and fluorescent images of the QC and target-specific probes of arrays containing only target-specific probes and those containing both QC and target-specific probes. In a comparison of quality control methods, it was found that the arrays containing QC probes could check spot-uniformity or spot defects during all processes of array fabrication, including after spotting, after washing, and after hybridization. In a comparison of quantification results, the array fabricated by the method using QC probes showed linear and regular results because it was possible to normalize variations in spot size and morphology and amount of attached probe. This method could avoid errors originating in probe concentration and spot morphology because it could be normalized by QC probes. There were significant differences in the signal intensities of all mixtures (P<0.05). This result indicates that the method using QC probes is more useful than the ordinary method for quantification of mixed target. In the quantification of mixed targets, this method could determine a range for mixed targets of various amounts. Our results suggest that methods using QC probes for array fabrication are very useful to the quality control of spots in the fabrication processes of quantitative oligonucleotide arrays.