• 제목/요약/키워드: normal section

검색결과 656건 처리시간 0.029초

최량수리단면의 등류수심 (Normal Depth of Best Section)

  • 유동훈
    • 한국수자원학회논문집
    • /
    • 제35권6호
    • /
    • pp.729-736
    • /
    • 2002
  • 개수로의 설계에 있어서 등류수심의 산정은 가장 기본적인 요건이며, 인공수로를 구축할 경우 일반적으로 최량 수리단면은 가장 경제적인 단면이 된다. 따라서 최량 수리단면의 등류수심 산정은 거의 모든 수로 설계의 핵심적인 요소라 할 수 있다. 개수로 마찰력을 산정하기 위하여 일반성이 확보된 지수형 마찰계수 산정식을 도입하였다. 삼각형, 사각형 및 제형 등 거의 모든 형태의 수로에 대한 등류수심의 산정을 위하여 형식이 통일되고 양해적으로 해석이 가능한 산정식을 도출하였다. 또한 이들 등류수심 산정식은 관로설계에서 도출된 관경 산정식과 형식이 일치함을 확인하였다.

Investigation of cold-formed stainless steel non-slender circular hollow section columns

  • Ellobody, Ehab;Young, Ben
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.321-337
    • /
    • 2007
  • The investigation on the behaviour of cold-formed stainless steel non-slender circular hollow section columns is presented in this paper. The normal strength austenitic stainless steel type 304 and the high strength duplex materials (austenitic-ferritic approximately equivalent to EN 1.4462 and UNS S31803) were considered in this study. The finite element method has been used to carry out the investigation. The columns were compressed between fixed ends at different column lengths. The geometric and material nonlinearities have been included in the finite element analysis. The column strengths and failure modes were predicted. An extensive parametric study was carried out to study the effects of normal and high strength materials on cold-formed stainless steel non-slender circular hollow section columns. The column strengths predicted from the finite element analysis were compared with the design strengths calculated using the American Specification, Australian/New Zealand Standard and European Code for cold-formed stainless steel structures. The numerical results showed that the design rules specified in the American, Australian/New Zealand and European specifications are generally unconservative for the cold-formed stainless steel non-slender circular hollow section columns of normal and high strength materials, except for the short columns and some of the high strength stainless steel columns. Therefore, different values of the imperfection factor and limiting slenderness in the European Code design rules were proposed for cold-formed stainless steel non-slender circular hollow section columns.

광 혈류 신호의 주파수 파워 특성과 이차 미분값을 이용한 가상환경의 스트레스 평가 (Assessment of stress in virtual reality environment using power spectral density ratio and second derivative of photoplethysmography)

  • Y.H. Nam;Kim, H.T.;H.D. Ko;Park, K.S.
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 추계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 2001
  • There are many people who suffer from simulation sickness when immersing in virtual reality. In this study, we analyzed two photoplethysmogram(PPG) parameters - a second derivative parameter and power spectral density ratios - in order to relate PPG parameters with simulation sickness. 36 young, healthy subjects were participated in the experiment, and each subject was equipped with a PPG electrode during his or her immersion. Simulation sickness section was defined as a 7 - second section which starts from the point where a subject reported simulation sickness, and normal section as a same-length section where no physical stimuli was presented to him or her. We compared the PPG parameters of the simulation sickness sections with the normal sections, - d/a ratio is believed to have lower value during vasodilation and higher value during vasoconstriction, however, we could not find much difference in the parameter between normal and simulation sickness sections. We also compared 1 to 10Hz power spectral density ratios in normal sections with in simulation sickness section, and found that 6 density ratios among them have different value. Therefore, the density ratios might be utilized as parameters to detect simulation sickness of subjects.

  • PDF

악관절장애환자의 하악과두 크기에 관한 연구 (A Study on the Size of TMD Patient's Condyle Head)

  • 이두희;오순호;서창호;김준배
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권5호
    • /
    • pp.417-422
    • /
    • 2001
  • Objective: In many TMD cases, deformed and reduced condyle heads were frequently observed. This study was prepared to compare the dimensions between normal and symptomatic condyles, using MR images. Materials: One hundred and twenty one patients with clinical signs and MRI-confirmed diagnosis of disc displacement were selected for this study. Thirty eight TMJs from nineteen asymptomatic volunteers who had no clinical symptoms and no disc displacement on sagittal and coronal view of MRI, were served as normal. Methods: Symptomatic condyles were classified according to the severity of the anterior disc displacement. The amount of anterior disc displacement was evaluated at sagittal section, and they were classified into 4 groups as normal(N), little(G0), mild(G1), moderate(G2) and severe displacement(G3). The dimentions of condyle were measured at the 200% magnified view, by digitizing program. All dimensions were compared among each groups on the central section of sagittal and coronal views, and the statistical analysis was performed. Results: The mean value of anteroposterior length of normal condyle was $0.79{\pm}0.13cm$ at sagittal section and mediolateral length was $2.12{\pm}0.22cm$ on coronal section. The mean value of anteroposterior length of symptomatic condyle was $0.67{\pm}0.16cm$ at sagittal section and mediolateral length was $1.97{\pm}0.28cm$ on coronal section. Conclusions: The size of symptomatic condyle was smaller than normal TMJ. The size of condyle was decreased as the amount of the disc displacement was increased. The dimensional change was found on the anterior articular surface of condyle at the mild or moderate disc displacement. And at the case of severe disc displacement, dimensional change was found on the superior articular surface.

  • PDF

다실 박스거더의 뒤틀림에 저항하는 강성 산정 (Evaluation of Stiffness Resisting Distortion of Multicell Box Girder)

  • 박남희;최영준;한금호;강영종
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.435-442
    • /
    • 2002
  • In a multicell box structure, distortional warping normal stress due to warping of cross section and transverse bending normal stress of walls due to distortion of cross section may consider as significant stresses unless distortion of box section is appropriately restricted. Nevertheless, during the past decades, no evaluation of distortional warping and transverse bending resistances for the multicell box section has been performed owing to geometric complexity and Insufficient information with respect to the distortion of multicell box section. The objective of present study is to evaluate the distortional warping and transverse bending resistances for the distortion of multicell box section and to validate the resistances through box girder analyses using multicell box beam element developed and conventional shell element. This developed box beam element has nine degrees of freedom per node including the effect of distortion.

  • PDF

원형단면을 포함하는 결합부의 강성평가 방법 연구 (A Study on the Evaluation of the Flexibility of Joint Area including Circular Section)

  • 국종영;박상준
    • 한국자동차공학회논문집
    • /
    • 제8권2호
    • /
    • pp.110-119
    • /
    • 2000
  • In this study, we considered the method evaluation the flexibility of joint area including member with circular section. We regarded the flexibility of joint area as translational and rotational springs for the purpose of expressing local deformation. We verified this method by the use of normal mode analysis. We also calculated this joint area occurring in penetration so as to apply this method to other cases. Compare with the shell element model. we can the considerably approximate values.

  • PDF

내부표적체적 설정을 통한 방사선치료계획 평가 (Radiation Treatment Planning Evaluation by Internal Target Volume Settings)

  • 박호춘;한재복;최남길
    • 한국콘텐츠학회논문지
    • /
    • 제15권8호
    • /
    • pp.416-423
    • /
    • 2015
  • 본 연구에서는 내부표적체적을 통한 방사선치료계획을 분석하여 호흡연동방사선치료에 주로 이용되는 호기상태의 치료계획체적과 비교 분석하여 정상조직이 받은 선량을 알아보았다. 2013년 12월부터 2014년 6월까지 모 대학교병원 방사선종양학과에서 복부부위에 호흡연동방사선치료를 받은 환자 25명을 대상으로 하였으며, 암의 종류는 liver(64%), CBD(8%), gastric(8%), GB(8%), pancreas(8%), SMA(4%)이었다. ITV와 PTV 체적의 평균치는 $471.44cm^3$, $425.48cm^3$ 로 체적의 증가를 알 수 있었고, PTV구간에서 ITV구간으로 선택한 구간의 증가로 인해 정상조직체적 또한 증가함을 알 수 있었다. 그리고 정상조직체적의 증가, target volume 증가, 치료조사야 면적증가의 차이와 정상조직이 받은 선량평균치의 차이에서는 right kidney가 유의한 증가를 보였다. 호흡평균치에 따른 정상조직이 받은 선량평균치의 차이는 없었고 target moving과 정상조직의 선량평균치의 차이에서는 both kidney가 유의한 차이를 나타내었다. 결론적으로 PTV구간과 ITV구간 체적 설정을 통한 치료방법이 모두 정상조직의 보호선량에 적합하였으며, 처방선량의 95% 이상이 분포하였으므로 환자의 치료목적에 따라 선택적으로 사용되어도 무방할 것이라 사료된다.

대형회전기기응용을 위한 GdBCO 레이스트랙형 팬케이크 코일의 ��치 발생과 전파특성에 관한 연구 (A Study on the Quench Initiation and Propagation Characteristics in GdBCO Racetrack Pancake Coil for Large-Scale Rotating Machines)

  • 양동규;송정빈;김광록;권오준;이우승;고태국;이해근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.24-30
    • /
    • 2011
  • The stability issue of high temperature superconducting (HTS) racetrack coils is one of the most important factors for the development of large-scale rotating machines, such as ship propulsion motors and power generators. However, The stability and normal zone propagation characteristics of HTS racetrack pancake (RP) coils are not sufficient yet. In this study, quench tests for a GdBCO racetrack pancake coil were carried out under the condition of $LN_2$ at 77 K. Minimum quench energy and two-dimensional normal zone propagation velocities of the coil are also discussed. Normal zone propagation velocity in the coil's curved section is faster than in its straight section due to stress effects. The test results show that the protection of the straight section is of greater importance than that of the curved section when GdBCO racetrack pancake coils are applied to large-scale rotating machines.