• 제목/요약/키워드: normal operator

검색결과 282건 처리시간 0.032초

한국노인에서 심장혈관계 질환 위험인자에 대한 비만지표인 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 타당도 비교 (Comparing Validity of Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Disease Risk Factors in Korean Elderly)

  • 문현경;김유진
    • Journal of Nutrition and Health
    • /
    • 제38권6호
    • /
    • pp.445-454
    • /
    • 2005
  • The purpose of this study was to compare the validity of obese index among body mass index (BMI), waist to hip ratio (WHR), and waist circumference (WC) and to determine which is the best in relation to cardiovascular disease (CVD) risk in Korean elderly more than 65 ages. Data from the 1998 Korean Health and Nutrition Survey were used (n=1017). Anthropometric indices and CVD risk factors were measured, and chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator Characteristic (ROC) curves were used in the analysis. Anthropometric values were decreased in both male and female when ages were goes up. In female elderly, it specially showed the characteristics of upper body fat and systolic blood pressure risk (p<0.05). Among life style factors the current smokers were prevalent in obese male (p<0.05), but not prevalent in female having obese or upper body fat. Also, person with upper body obesity have more exercise than that of normal group (p<0.01). Mean BMI values of the current smoker was lower than that of normal group in both sexes (p<0.01). Mean BMI value of person with other risk factors were higher than that of normal groups (p<0.05). Among 7 CVD risk factors in partial correlation analysis, WC had the highest correlation coefficient in 5 in male, whereas BMI in 4 in female. In ROC analyses of 12 risk factors and health conditions, the largest area under curve of obese indices for risk factors were WC>WHR>BMI in male and BMI>WHR>WC in female. The optimal cutoff values of each index (BMI : WHR : WC) for one or more risk factors were 19.02 : 0.84 : 71.3 in male and 19.04 : 0.88 : 85.6 in female. In conclusion, Most Korean elderly showed non-obese and abdominal obesity likewise other Asians. Also CVD risk factors were prevalent in Korean elderly within normal limits of obese indices. Therefore the upper body fat indices reflected in the aged whose muscle mass is replaced by fat must be used as an indicator of CVD risk together with BMI. Although WHR was the worst index based on partial correlation analysis and so located between BMI and WC in ROC curve analysis in both sexes, it need to be use with WC to screen the cardiovascular risk group.

The role of the iliotibial band cross-sectional area as a morphological parameter of the iliotibial band friction syndrome: a retrospective pilot study

  • Park, Jiyeon;Cho, Hyung Rae;Kang, Keum Nae;Choi, Kun Woong;Choi, Young Soon;Jeong, Hye-Won;Yi, Jungmin;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • 제34권2호
    • /
    • pp.229-233
    • /
    • 2021
  • Background: Iliotibial band friction syndrome (ITBFS) is a common disorder of the lateral knee. Previous research has reported that the iliotibial band (ITB) thickness (ITBT) is correlated with ITBFS, and ITBT has been considered to be a key morphologic parameter of ITBFS. However, the thickness is different from inflammatory hypertrophy. Thus, we made the ITB cross-sectional area (ITBCSA) a new morphological parameter to assess ITBFS. Methods: Forty-three patients with ITBFS group and from 43 normal group who underwent T1W magnetic resonance imaging were enrolled. The ITBCSA was measured as the cross-sectional area of the ITB that was most hypertrophied in the magnetic resonance axial images. The ITBT was measured as the thickest site of ITB. Results: The mean ITBCSA was 25.24 ± 6.59 ㎟ in the normal group and 38.75 ± 9.11 ㎟ in the ITBFS group. The mean ITBT was 1.94 ± 0.41 mm in the normal group and 2.62 ± 0.46 mm in the ITBFS group. Patients in ITBFS group had significantly higher ITBCSA (P < 0.001) and ITBT (P < 0.001) than the normal group. A receiver operator characteristic curve analysis demonstrated that the best cut-off value of the ITBT was 2.29 mm, with 76.7% sensitivity, 79.1% specificity, and area under the curve (AUC) 0.88. The optimal cut-off score of the ITBCSA was 30.66 ㎟, with 79.1% sensitivity, 79.1% specificity, and AUC 0.87. Conclusions: ITBCSA is a new and sensitive morphological parameter for diagnosing ITBFS, and may even be more accurate than ITBT.

Optimization of energy saving device combined with a propeller using real-coded genetic algorithm

  • Ryu, Tomohiro;Kanemaru, Takashi;Kataoka, Shiro;Arihama, Kiyoshi;Yoshitake, Akira;Arakawa, Daijiro;Ando, Jun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.406-417
    • /
    • 2014
  • This paper presents a numerical optimization method to improve the performance of the propeller with Turbo-Ring using real-coded genetic algorithm. In the presented method, Unimodal Normal Distribution Crossover (UNDX) and Minimal Generation Gap (MGG) model are used as crossover operator and generation-alternation model, respectively. Propeller characteristics are evaluated by a simple surface panel method "SQCM" in the optimization process. Blade sections of the original Turbo-Ring and propeller are replaced by the NACA66 a = 0.8 section. However, original chord, skew, rake and maximum blade thickness distributions in the radial direction are unchanged. Pitch and maximum camber distributions in the radial direction are selected as the design variables. Optimization is conducted to maximize the efficiency of the propeller with Turbo-Ring. The experimental result shows that the efficiency of the optimized propeller with Turbo-Ring is higher than that of the original propeller with Turbo-Ring.

Electricity Price Forecasting in Ontario Electricity Market Using Wavelet Transform in Artificial Neural Network Based Model

  • Aggarwal, Sanjeev Kumar;Saini, Lalit Mohan;Kumar, Ashwani
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.639-650
    • /
    • 2008
  • Electricity price forecasting has become an integral part of power system operation and control. In this paper, a wavelet transform (WT) based neural network (NN) model to forecast price profile in a deregulated electricity market has been presented. The historical price data has been decomposed into wavelet domain constitutive sub series using WT and then combined with the other time domain variables to form the set of input variables for the proposed forecasting model. The behavior of the wavelet domain constitutive series has been studied based on statistical analysis. It has been observed that forecasting accuracy can be improved by the use of WT in a forecasting model. Multi-scale analysis from one to seven levels of decomposition has been performed and the empirical evidence suggests that accuracy improvement is highest at third level of decomposition. Forecasting performance of the proposed model has been compared with (i) a heuristic technique, (ii) a simulation model used by Ontario's Independent Electricity System Operator (IESO), (iii) a Multiple Linear Regression (MLR) model, (iv) NN model, (v) Auto Regressive Integrated Moving Average (ARIMA) model, (vi) Dynamic Regression (DR) model, and (vii) Transfer Function (TF) model. Forecasting results show that the performance of the proposed WT based NN model is satisfactory and it can be used by the participants to respond properly as it predicts price before closing of window for submission of initial bids.

Singular Representation and Finite Element Methods

  • 김석찬
    • 한국전산응용수학회:학술대회논문집
    • /
    • 한국전산응용수학회 2003년도 KSCAM 학술발표회 프로그램 및 초록집
    • /
    • pp.9-9
    • /
    • 2003
  • Let $\Omega$ be a bounded, open, and polygonal domain in $R^2$ with re-entrant corners. We consider the following Partial Differential Equations: $$(I-\nabla\nabla\cdot+\nabla^{\bot}\nabla\times)u\;=\;f\;in\;\Omega$$, $$n\cdotu\;0\;0\;on\;{\Gamma}_{N}$$, $${\nabla}{\times}u\;=\;0\;on\;{\Gamma}_{N}$$, $$\tau{\cdot}u\;=\;0\;on\;{\Gamma}_{D}$$, $$\nabla{\cdot}u\;=\;0\;on\;{\Gamma}_{D}$$ where the symbol $\nabla\cdot$ and $\nabla$ stand for the divergence and gradient operators, respectively; $f{\in}L^2(\Omega)^2$ is a given vector function, $\partial\Omega=\Gamma_{D}\cup\Gamma_{N}$ is the partition of the boundary of $\Omega$; nis the outward unit vector normal to the boundary and $\tau$represents the unit vector tangent to the boundary oriented counterclockwise. For simplicity, assume that both $\Gamma_{D}$ and $\Gamma_{N}$ are nonempty. Denote the curl operator in $R^2$ by $$\nabla\times\;=\;(-{\partial}_2,{\partial}_1$$ and its formal adjoint by $${\nabla}^{\bot}\;=\;({-{\partial}_1}^{{\partial}_2}$$ Consider a weak formulation(WF): Find $u\;\in\;V$ such that $$a(u,v):=(u,v)+(\nabla{\cdot}u,\nabla{\cdot}v)+(\nabla{\times}u,\nabla{\times}V)=(f,v),\;A\;v{\in}V$$. (2) We assume there is only one singular corner. There are many methods to deal with the domain singularities. We introduce them shortly and we suggest a new Finite Element Methods by using Singular representation for the solution.

  • PDF

연구용 원자로 이차정지구동장치 수력시스템의 내진검증 (Seismic Qualification Test for SSDM Hydraulic System of Research Reactor)

  • 김상헌;김경호;선종오;조영갑;정택형;김정현;이관희
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.23-29
    • /
    • 2016
  • The Second Shutdown Drive Mechanism (SSDM) provides an alternate and independent means of reactor shutdown. The Second Shutdown Rods (SSRs) of SSDMs are poised at the top of the core by the hydraulic force driven from a hydraulic system during normal operation. The rods drop by gravity when a trip is commended by a Reactor Protection System, Alternate Protection System, Automatic Seismic Trip System or operator by means of power off solenoid valves of hydraulic system. This paper describes the test results of seismic qualification of a prototype SSDM hydraulic system to demonstrate that its structural integrity and operability (functionality) are maintained during and after seismic excitations, that is, an adequacy of the SSDM design. From the results, this paper shows that the SSDM hydraulic system satisfies all its design requirements without any malfunctions during and after seismic excitations.

CHARACTERIZATIONS OF CENTRALIZERS AND DERIVATIONS ON SOME ALGEBRAS

  • He, Jun;Li, Jiankui;Qian, Wenhua
    • 대한수학회지
    • /
    • 제54권2호
    • /
    • pp.685-696
    • /
    • 2017
  • A linear mapping ${\phi}$ on an algebra $\mathcal{A}$ is called a centralizable mapping at $G{\in}{\mathcal{A}}$ if ${\phi}(AB)={\phi}(A)B= A{\phi}(B)$ for each A and B in $\mathcal{A}$ with AB = G, and ${\phi}$ is called a derivable mapping at $G{\in}{\mathcal{A}}$ if ${\phi}(AB)={\phi}(A)B+A{\phi}(B)$ for each A and B in $\mathcal{A}$ with AB = G. A point G in A is called a full-centralizable point (resp. full-derivable point) if every centralizable (resp. derivable) mapping at G is a centralizer (resp. derivation). We prove that every point in a von Neumann algebra or a triangular algebra is a full-centralizable point. We also prove that a point in a von Neumann algebra is a full-derivable point if and only if its central carrier is the unit.

The Performance Evaluation of NSSS Control Systems for UCN 4

  • Sohn, Suk-Whun;Song, In-Ho;Sohn, Jong-Joo;Park, Jong-Ho;Seo, Jong-Tae
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.339-348
    • /
    • 2001
  • NSSS Control Systems automatically mitigate transient conditions and leads to a stable plant condition without operator actions when a transient occurs during normal power operation. In this paper, the function and performance of NSSS control systems were examined and evaluated by comparing the predicted results with the measured data for the selected events. Loss of a Main Feedwater Pump and Load Rejection to House Load Operation events were selected for the evaluation among the transient tests peformed during the Power Ascension Test (PAT) of UCN unit 4. The overall schematic control actions of NSSS control systems can be evaluated easily through the observation of these two typical events. The selected events were analyzed by the KISPAC computer code[l] which had been used in developing the control logic and determining the control setpoints during the plant design. Additionally, the performance of FWCS during low power operation was evaluated. The result of evaluation showed that the NSSS control systems were designed properly and the performance of the NSSS control systems was excellent and also the computer code had a good prediction capability.

  • PDF

임플란트 식립후 하악 신경손상에 대한 후향적 연구 (THE PREVALENCE OF SENSORY DISTURBANCE AFTER IMPLANT SURGERY - RETROSPECTIVE SURVEY OF IMPLANT PRACTITIONERS)

  • 권대근;김신유;김종배
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.339-344
    • /
    • 2004
  • The purpose of this study was to evaluate neurosensory disturbance associated with implant surgery performed by implant practitioner (n=47) composed of trained oral surgeon, periodontist, prosthodontist. The incidence, type and duration of sensory disorder were investigated. Anatomical factor of the patient and experience of operator were also evaluated. The result revealed high incidence of inferior alveolar nerve damage (45%) regardless of experience of implant practitioner. The sensory disturbance sustained within 6 months for 61% of cases, which revealed almost normal recovery of nerve function. Initial neurologic sign after nerve damage was not coincide with their consequence of recovery. Half of the practitioners tried surgical intervention to the implants such as removing the fixture, partial unscrewing or re-implant shorter fixture, of which trial regarded as effective measure for 53% of cases. The result indicates that the objective method of sensory nerve evaluation should be introduced to the implant practitioners and the importance of informed consent for possibility of nerve damage in mandibular implant fixation.

동적시간와핑을 이용한 연속회분식 반응기의 장비고장 감지 (Detection of Equipment Faults at Sequencing Batch Reactor Using Dynamic Time Warping)

  • 김예진
    • 한국환경과학회지
    • /
    • 제25권4호
    • /
    • pp.525-534
    • /
    • 2016
  • The biological wastewater treatment plant, which uses microbial community to remove organic matter and nutrients in wastewater, is known as its nonlinear behavior and uncertainty to operate. Therefore, operation of the biological wastewater treatment process much depends on observation and knowledge of operators. The manual inspection of human operators is essential to manage the process properly, however, it is impossible to detect a fault promptly so that the process can be exposed to improper condition not securing safe effluent quality. Among various process faults, equipment malfunction is critical to maintain normal operational state. To detect equipment faults automatically, the dynamic time warping was tested using on-line oxidation-reduction potential (ORP) and dissolved oxygen (DO) profiles in a sequencing batch reactor (SBR), which is a type of wastewater treatment process. After one cycle profiles of ORP and DO were measured and stored, they were warped to the template profiles which were prepared already and the distance result, accumulated distance (D) values were calculated. If the D values were increased significantly, some kinds of faults could be detected and an alarm could be sent to the operator. By this way, it seems to be possible to make an early detecting of process faults.