• 제목/요약/키워드: normal mode

검색결과 1,019건 처리시간 0.026초

The effect of rotation on piezo-thermoelastic medium using different theories

  • Othman, Mohamed I.A.;Ahmed, Ethar A.A.
    • Structural Engineering and Mechanics
    • /
    • 제56권4호
    • /
    • pp.649-665
    • /
    • 2015
  • The present paper attempts to investigate the propagation of plane waves in generalized piezo-thermoelastic medium under the effect of rotation. The normal mode analysis is used to obtain the expressions for the displacement components, the temperature, the stress and the strain components. Comparisons are made with the results predicted by different theories (Coupled theory, Lord-Schulman, Green-Lindsay) in the absence and presence of rotation.

Disturbance due to internal heat source in thermoelastic solid using dual phase lag model

  • Ailawalia, Praveen;Singla, Amit
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.341-354
    • /
    • 2015
  • The dual-phase lag heat transfer model is employed to study the problem of isotropic generalized thermoelastic medium with internal heat source. The normal mode analysis is used to obtain the exact expressions for displacement components, force stress and temperature distribution. The variations of the considered variables through the horizontal distance are illustrated graphically. The results are discussed and depicted graphically.

원형단면을 포함하는 결합부의 강성평가 방법 연구 (A Study on the Evaluation of the Flexibility of Joint Area including Circular Section)

  • 국종영;박상준
    • 한국자동차공학회논문집
    • /
    • 제8권2호
    • /
    • pp.110-119
    • /
    • 2000
  • In this study, we considered the method evaluation the flexibility of joint area including member with circular section. We regarded the flexibility of joint area as translational and rotational springs for the purpose of expressing local deformation. We verified this method by the use of normal mode analysis. We also calculated this joint area occurring in penetration so as to apply this method to other cases. Compare with the shell element model. we can the considerably approximate values.

  • PDF

광 스트립 도파로의 등가회로망 해석 (Equivalent network analysis of optical strip waveguides)

  • 이재승
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.225-229
    • /
    • 1989
  • Taking the normal mode transmission direction perpendicular to the substrate, an alternative equivalent network formulation is developed for the analysis of optical strip waveguides. All kinds of mode couplings between the normal modes are included in this formulation. Compared to the previous equivalent network formulations, the calculations are simplified especially when the thickness of the uniform slab is thin enough such that no well guided modes are available along the uniform slab waveguide.

  • PDF

대화면 스마트폰의 한 손 조작 시 터치 사각영역 지원 인터랙션의 유용성 (Validating one-handed interaction modes for supporting touch dead-zone in large screen smartphones)

  • 박민지;김헌
    • 한국HCI학회논문지
    • /
    • 제12권1호
    • /
    • pp.25-32
    • /
    • 2017
  • 본 연구의 목적은 대화면 스마트폰을 한 손으로 조작 시 터치가 어려운 사각영역의 효율적인 터치를 지원하는 한 손 모드 인터랙션의 유용성을 평가하는 것이다. 이를 위해 아이폰과 안드로이드 스마트폰 내 두 종류의 기존 한손 모드들을 분석하였고, 보다 유용할 것으로 기대되는 두 개 유형의 한 손 모드들을 추가적으로 제안하고 구현하였다. 기존 및 제안한 한 손 모드들의 유용성을 검증하기 위해, 네 개의 한 손 모드들과 일반터치를 비교하는 실험을 수행하였다. 실험 결과, 일반터치에 비해 한 손 모드로 사각영역을 터치하는데 오히려 더 긴 시간이 걸렸다. 이는 한손 모드의 경우 모드진입 조작 및 모드전환 애니메이션 시간이 기본적으로 필요했기 때문이었다. 그러나 실험참여자들이 일반터치로 사각영역을 터치 시에는 엄지를 많이 뻗어서 터치해야 해서 손의 위치변화가 커지고 연속된 조작을 어려워하였다. 또한 한 손 모드로의 전환효과와 터치 조작반경의 축소로 인하여 주관적 만족도는 한 손 모드를 사용하는 것이 더 높았다. 한편, 한 손 모드들 중에서는 아이폰의 하단이동 한 손 모드가 가장 좋은 것으로 평가되었다.

Dosimetry Check™를 이용한 MVCT 선량계산 모델 구축에 관한 연구 (A Study on the Construction of MVCT Dose Calculation Model by Using Dosimetry Check™)

  • 엄기천;김창환;전수동;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.431-441
    • /
    • 2020
  • The purpose of this study was to construct a model of MVCT(Megavoltage Computed Tomography) dose calculation by using Dosimetry Check™, a program that radiation treatment dose verification, and establish a protocol that can be accumulated to the radiation treatment dose distribution. We acquired sinogram of MVCT after air scan in Fine, Normal, Coarse mode. Dosimetry Check™(DC) program can analyze only DICOM(Digital Imaging Communications in Medicine) format, however acquired sinogram is dat format. Thus, we made MVCT RC-DICOM format by using acquired sinogram. In addition, we made MVCT RP-DICOM by using principle of generating MLC(Multi-leaf Collimator) control points at half location of pitch in treatment RP-DICOM. The MVCT imaging dose in fine mode was measured by using ionization chamber, and normalized to the MVCT dose calculation model, the MVCT imaging dose of Normal, Coarse mode was calculated by using DC program. As a results, 2.08 cGy was measured by using ionization chamber in Fine mode and normalized based on the measured dose in DC program. After normalization, the result of MVCT dose calculation in Normal, Coarse mode, each mode was calculated 0.957, 0.621 cGy. Finally, the dose resulting from the process for acquisition of MVCT can be accumulated to the treatment dose distribution for dose evaluation. It is believed that this could be contribute clinically to a more realistic dose evaluation. From now on, it is considered that it will be able to provide more accurate and realistic dose information in radiation therapy planning evaluation by using Tomotherapy.

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

모드해석을 이용한 L, T 자형 구조물의 결합 강성 평가 방법에 대한 연구 (The Study of Stiffness Evaluation Technique for L, T Shaped Joint Structures Using Normal Modes Analysis with Lumped Mass)

  • 허덕재;정재엽;조연;박태원
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.975-983
    • /
    • 1999
  • This paper describes the dynamic characteristics of the joint structures in case of using the simplified beam model in the F. E. analysis. The modeling errors, when replace the shell with the beam, are investigated through F. E. normal modes analysis. Normal mode analysis were performed to obtain the natural frequencies of the L and T shaped joints with various type of channels. The results were analyzed to access the effects of the models on the accuracy of F.E. analysis by identifying the geometric factors which cause the error. The geometric factors considered are joint angle, channel length, thickness and area ratio of the hollow section to the filled one. The joint stiffness evaluation technique is developed in this study using normal modes analysis with Lumped Mass. With this method, the progressively improved results of F. E. analysis are obtained using the simplified beam model. The static and normal modes analysis are performed with the joint stiffness values obtained by the Kazunori Shimonkakis' virtual stiffness method and the proposed method and these simplified modeling errors are compared.

  • PDF

적분 슬라이딩 모드 제어기를 이용한 출력 궤환 안정화 (Output Feedback Stabilization using Integral Sliding Mode Control)

  • 오승록
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권3호
    • /
    • pp.142-147
    • /
    • 2003
  • We consider a single-input-single-output nonlinear system which can be represented in a normal form. The nonlinear system has a modeling uncertainties including the input coefficient uncertainty. A high-gain observer is used to estimate the states variables to reject a modeling uncertainty. A globally bounded output feedback integral sliding mode control is proposed to stabilize the closed loop system. The proposed integral sliding mode control can asymptotically stabilize the closed loop system in the presence of input coefficient uncertainty.

ESS 기능을 갖는 단상 이중변환 UPS (Single-Phase Double-Conversion UPS with Energy Storage System)

  • 임승범;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.137-138
    • /
    • 2013
  • This paper proposes the single-phase double-conversion UPS(Uninterruptible Power Supply) with ESS(Energy Storage System). The Proposed system is operating in three modes, which are normal mode, battery mode, and bypass mode. Not only in black-out but also in peak load times, the system is operating in battery mode which is using the stored energy of the battery to manage the power effectively. The validity of proposed system could be verified by simulations and experiments.

  • PDF