• Title/Summary/Keyword: nonunion fracture

Search Result 120, Processing Time 0.023 seconds

Malunion of the Jaw Fractures Complicated Following the Primary Managements (악골절 치료후 부정유합에 관한 임상적 연구)

  • Kim, Dae-Sung;Kim, Myung-Rae;Choi, Jang-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.356-360
    • /
    • 1999
  • PURPOSE : This is to review the complicated jaw fractures that had been referred for revision of the unsatisfactory results, and to provide proper managements for the easily complicated jaw fractures. MATERIALS & METHODS : Twenty-nine patients who had been revised due to malunion or complicated fractures of facial bones for last 3 years were reviewed. The main problems required for revision, type of fractures complicated, the primary managements to be reclaimed, the specialties to be involved, the management to be reclaimed, time elapsed to seek reoperation, type of revision surgeries, residual complication were analysed with medical records, radiographs and final examinations. RESULTS: The major complaints were malocclusion(79.3%), facial disfigurement(41.3%), TMJ problems (13.7%), neurologic problems(10.3%), non-union(10.3%), and infection(6.8%). Unsatisfactory results were occurred most frequently after improper management of the multiple fractures of the mandible (62.2%), combined fractures of maxilla and mandible (20.6%), fracture of zygomatico-maxillary complex and midpalate (17.2%). The complications to be corrected were widened or collapsed dental arches (79.3%), improperly reduced condyles (41.3%), painful TMJ (34.4%), limited jaw excursion (31.0%), over-reduction of zygoma (13.7%), and nonunion with infection(13.7%). and dysesthesia (10.3%). The primary managements were nendereet by plastic surgeons in 82.7%(24/29) and by oral surgeons in 7.6%(2/29). Main causes of malunion are inadequate ORIF in 76%, unawareness & delay in 17%, and delayed due to systemic cares in 17%. 76% of 29 patients had been in state of intermaxillary fixation for over 4 weeks. Revision were done by means of "refracture and ORIF"in 48.2%(14/29), orthognathic osteotomies with bone grafts in 55.1%(16/29), and camouflage countering & alloplastic implantations in 37.9%(11/29), TMJ surgeries in 17.2%, micro-neurosurgeries in 11.6%. Residual complications were limited mouth opening in 24.1% (7/29), paresthesia in 13.7%, resorption of reduced condyle in 10.3%. CONCLUSIONS : Failure of initial treatment of jaw fractures is due to improper diagnosis and inadequate treatment with lack of sufficient knowledge of stomatognathic system. It is crucial to judge jaw fracture and patients accurately, moreover, the best way of treatments has to be selected. Consideration of these factors in treatment could minimize the complication of jaw fractures.

  • PDF

In vivo 3-dimensional Kinematics of Cubitus Valgus after Non-united Lateral Humeral Condyle Fracture

  • Kim, Eugene;Park, Se-Jin;Lee, Ho-Seok;Park, Jai-Hyung;Park, Jong Kuen;Ha, Sang Hoon;Murase, Tsuyoshi;Sugamoto, Kazuomi
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.151-157
    • /
    • 2018
  • Background: Nonunion of lateral humeral condyle fracture causes cubitus valgus deformity. Although corrective osteotomy or osteosynthesis can be considered, there are controversies regarding its treatment. To evaluate elbow joint biomechanics in non-united lateral humeral condyle fractures, we analyzed the motion of elbow joint and pseudo-joint via in vivo three-dimensional (3D) kinematics, using 3D images obtained by computed tomography (CT) scan. Methods: Eight non-united lateral humeral condyle fractures with cubitus valgus and 8 normal elbows were evaluated in this study. CT scan was performed at 3 different elbow positions (full flexion, $90^{\circ}$ flexion and full extension). With bone surface model, 3D elbow motion was reconstructed. We calculated the axis of rotation in both the normal and non-united joints, as well as the rotational movement of the ulno-humeral joint and pseudo-joint of non-united lateral condyle in 3D space from full extension to full flexion. Results: Ulno-humeral joint moved to the varus on the coronal plane during flexion, $25.45^{\circ}$ in the non-united cubitus valgus group and $-2.03^{\circ}$ in normal group, with statistically significant difference. Moreover, it moved to rotate externally on the axial plane $-26.75^{\circ}$ in the non-united cubitus valgus group and $-3.09^{\circ}$ in the normal group, with statistical significance. Movement of the pseudo-joint of fragment of lateral condyle showed irregular pattern. Conclusions: The non-united cubitus valgus group moved to the varus with external rotation during elbow flexion. The pseudo-joint showed a diverse and irregular motion. In vivo 3D motion analysis for the non-united cubitus valgus could be helpful to evaluate its kinematics.

Current Treatment of Tibial Pilon Fractures (경골 천정(pilon) 골절의 최신 치료)

  • Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

Coracoclavicular Ligament Augmentation Using Endobutton for Unstable Distal Clavicle Fractures - Preliminary Report - (불안정성 쇄골 원위부 골절에서의 Endobutton을 이용한 오구 쇄골 인대 보강술 - 예비 보고 -)

  • Cho, Chul-Hyun;Jung, Gu-Hee;Sin, Hong-Kwan;Lee, Young-Kuk;Park, Jin-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after operative treatment using endobuttons for unstable distal clavicle fractures. Materials and Methods: Between October 2007 and September 2009, 9 consecutive patients who were followed up for at least more than 12 months after operative treatment using a TightRope$^{(R)}$ were studied. The radiologic results on the serial plain radiographs and the clinical results according to the American Shoulder Elbow Surgeons (ASES) score were analyzed. Result: Bony union was shown in 8 cases (88.9%) and the average time to union was 12.9 (range: 9~16) weeks. The average coracoclavicular distances at the postoperative and final follow-up were 5.6 mm and 6.2 mm, respectively, with no statistically significant difference (p>0.05). The average ASES score was 90.3 (range: 78~96) and the clinical outcomes were 6 excellent, 2 good and one fair. There were no complications such as implant failure or infection except for one case of nonunion due to loss of the initial reduction. Conclusion: A major advantage of TightRope$^{(R)}$ fixation for unstable distal clavicle fractures is that no further surgery is needed to remove the implant. We suggest that this technique provides an alternative for fracture with a distal fragment, which is difficult to fix.

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

Operative Treatment of the Clavicular Midshaft Fractures in Adult - A Comparison between Intramedullary Multiple Steinmann Pins Fixation and Reconstruction Plate Fixation - (성인 쇄골 간부 골절의 수술적 치료-골수강내 다발성 Steinmann핀 고정술과 재구성 금속판 고정술과의 비교-)

  • Lee Young Kuk;Gu Hae Seo
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.14-20
    • /
    • 1999
  • Purpose: Despite of the popular use of the reconstruction plate for the fixation of clavicular shaft fractures, some disadventages have been raised such as long period of immobilization, long skin incision, loosening of plate and screws, and increased chance of nonunion due to severe periosteal injury. Thus, the authors have performed intramedullary multiple Steinmann pins fixation that could reduce the disadvantages of plate fixation in order to compare the treatment results between the two groups. Materials & Methods: From 1994. Jan. to 1997. Dec. the department of orthopaedic surgery of the Kwak's hospital treated operatively for 56 cases of the clavicular shaft fractures in adult. 39 cases of them were treated with the plate fixation and 17 cases with the intramedullary multiple Steinmann pins fixation(SP group). Reconstruction plates(Plate group) were used for 26 out of 39 patients treated with plate fixation. Among the Plate group and SP group, each 15 cases were selected by age and sex and compared each other according to the bone union time, union rate, complication, and functional results. The follow-up period was 12 months at the shortest and 48 months at the longest and the average was 16 months. Results: The Plate group showed that the bone union time was 7 weeks and the bone union rate was 93%. The SP group showed 6.5 weeks and 100% respectively. In complication, the Plate group had 1 case of loosening of plate and screws and delayed union; SP group had 1 case of pin migration. The functional results according to Kang's criteria, 87% of the Plate group and 93% of the SP group showed good or excellent. Conclusion : The SP group showed very comparable results in terms of the bone union time, bone union rate, complication, and functional results comparing to the Plate group. The intramedullary multiple Steinmann pins fixation showed several advantages over the reconstruction plate fixation, which were simple operative technique, easy removal of pins, being able to perform immediate postoperative full range of motion exercise. Therefore, the intramedullary multiple Steinmann pins fixation is thought to be one of the useful operative techniques in treatment of the clavicular shaft fractures in adult.

  • PDF

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Limb Salvage Operation with Recycled Autogenous Bone Graft (자가골 재이식술을 이용한 사지 구제술)

  • Rhee, Seung-Koo;Kang, Yong-Koo;Suh, Yoo-Joon;Yoo, Jong-Min;Jung, In-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.96-106
    • /
    • 2004
  • Purpose: To determine the usefulness of limb salvage operation with recycled autogenous bone graft in musculoskeletal malignant tumors. Materials and Methods: Twenty nine cases, who underwent limb salvage operation with recycled autogenous bone graft for the treatment of musculoskeletal malignant tumor between February 1990 and January 2003, were included. There were 18 males and 11 females and the mean age was 33 years (range, 10 to 65 years). The mean follow-up period was 51.8 months (range, 18 to 117 months). The Enneking stage was IIA in 10 cases and IIB in 19 cases. The recycling method of autogenous bone was deep freezing in 6 cases, autoclaving in 11 cases, pasteurization in 7 cases and the composite of autoclaving and vascularized fibular graft in 5 cases. The union of junctional site was evaluated radiologically and the functional results was analyzed by the grading systems of the International Symposium On Limb Salvages (ISOLS). Results: The mean union time was 7.2 months (range, 3 to 15 months). The union took 5.8 months (range, 4 to 8 months) in deep freezing, 9.7 months (range, 6 to 15 months) in autoclaving, 5.9 months (range, 4 to 8 months) in pasteurization, and 5 months (range, 4 to 8 months) in the composite of autoclaving and vascularized fibular graft. The mean functional evaluation percentage was 76.8% (range, 40 to 90%). It was 65.8% (range, 40 to 85%) in deep freezing, 76.6% (range, 40 to 90%) in autoclaving, 81.6% (range, 70 to 90%) in pasteurization, and 83.4% (range, 75 to 90%) in the composite of autoclaving and vascularized fibular graft. There were 6 cases of complications including 1 case of local recurrence, lung metastasis, infection, fracture, respectively and 2 cases of nonunion. Conclusion: The limb salvage operation with recycled autogenous bone graft is a useful treatment method for the musculoskeletal malignant tumors. Particularly, autoclaving is the most reliable sterilization method. The vascularized fibular graft can compensate decreased osteoinductivity and mechanical strength of recycled bone. So, the composite of autoclaving and vascularized bone graft seems to be a favorable treatment method for high grade malignant musculoskeletal tumors.

  • PDF

The Reconstruction with Extracorporeal Irradiated Autograft for Osteosarcoma of Extremities (사지 골육종에서 체외 방사선 조사를 이용한 재건술)

  • Kim, Jae-Do;Lee, Gun-Woo;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: With advances in various treatment modalities, limb salvage surgery has been commonly used in osteosarcoma of extremities. An alternative method for skeletal reconstruction is reimplantation of the tumor bearing bone following extracorporeal irradiation (ECI). We report the long-term results of ECI autograft in aspect of the oncological and functional outcomes, and complications. Materials and Methods: We retrospectively reviewed 31 osteosarcoma patients who underwent reconstruction with ECI between July 1995 and January 2006. There were 24 males and 7 females with a mean age of 24 (7-74 years) and a mean follow-up of 117 months (17-177 months). Twenty-five cases were reconstructed with ECI autograft, 6 cases with ECI autograft-prosthesis composite. The pathologic subtypes were conventional in 29 cases, periosteal in 1 case, and parosteal in 1 case. The most common location of tumor was distal femur (15 cases) followed by humerus (3), proximal fibula (3) and proximal tibia (3). Musculoskeletal Tumor Society (MSTS) score was used for functional evaluation. The overall survival rate, local recurrence, complications were analyzed. Results: The overall survival rate was 80.6% and the disease-free survival rate was 64.5%. Five patients died of distant metastasis. One patient required above-knee amputation due to local recurrence. All of them, twenty-three complications occurred, which included nonunion in 7 cases, deep infection in 5 cases, joint instability in 4 cases, metal failure in 2 cases, Limb-length discrepancy (LLD) in 2 cases, periprosthetic fracture in 1 case, epiphyseal collapse in 1, local recurrence in 1 case. The mean MSTS functional score was 62.5%. Conclusion: Extracorporeal irradiated autograft can be achieved relatively good result in aspect of oncological and functional aspect, but is needed to be additional research about occurring many complications. The reconstruction with ECI after intercalary or fragmentary resection is effective reconstruction in aspect of oncological and functional result, complications.

Midterm Results of Bipolar Hemiarthroplasty for Unstable Intertrochanteric Femoral Fractures Using a Type 3C Cementless Stem (불안정성 대퇴골 전자간 골절에 3C형 무시멘트 대퇴 스템을 이용한 고관절 반치환술의 중기 결과)

  • Chung, Woochull;Cho, Hong Man;Kim, Sun do;Park, Jiyeon;Kwon, Kihyun;Lee, Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • Purpose: Bipolar hemiarthroplasty is used as an alternative to open reduction and internal fixation for unstable intertrochanteric fractures in elderly patients. Recent advances in medical systems and technologies have resulted in increased survival rates after intertrochanteric fractures of the femur, requiring selection of the appropriate femoral stems considering the mid- to long-term duration of survival. Hemiarthroplasty was performed for unstable intertrochanteric fractures using a double tapered quadrilateral femoral stem (C2 stem), and the clinical and radiological results were evaluated as a five-year follow-up post-surgery. Materials and Methods: From January 2004 to December 2013, 43 patients (43 hips) who underwent hemiarthroplasty with a C2 stem were enrolled in this study. Their mean age was 78.6 years (range, 70-84 years), and the mean follow-up period was 85.4 months (range, 60-96 months). During the follow-up period, clinical parameters, such as the changes in pain, walking ability, and functional status, were examined. Radiologically, changes in the proximal femur, such as osteoporosis and bone resorption of cortical bone, were noted. Complications that occurred during the follow-up period, such as dislocation and prosthetic features, were also reviewed. Results: Initially, the pain was relieved postoperatively, but it increased four years after surgery. The walking ability was reduced by two steps in nine patients after 60 months, and the Harris hip score was reduced significantly postoperatively after two to three years. Radiologically, cortical osteoporosis occurred in 14 patients. Five patients developed cortical bone resorption. Four of them showed nonunion of the trochanteric fracture fragments, and three of them suffered reverse oblique fractures. Conclusion: Careful selection considering the general health condition and remaining lifespan of the patient would be necessary for primary hip hemiarthroplasty using a 3C type cementless femoral stem for unstable intertrochanteric fractures in elderly patients with osteoporosis.