• Title/Summary/Keyword: non-metal

Search Result 1,686, Processing Time 0.664 seconds

금속문화재 복원의 부적절한 사례 연구 - 비전문가에 의한 금속문화재 복원 및 비가역성 재료를 이용한 잘못된 복원사례 - (Case Studies of Destructive Restoration of the Metal Relics and Their Problems - Derelict restorations by non-conservators and their ignorant use of irreversible materials -)

  • 황진주;한민수
    • 보존과학연구
    • /
    • 통권30호
    • /
    • pp.63-77
    • /
    • 2009
  • Scientific studies of conservation techniques and materials in Korea have experienced fast development since international practice and academic knowledge have been introduced to Korea from Japan, France, Germany, and etc from the late 1960s. In recent years, it has been observed that the academic standard of research and the level knowledge of the field in Korea at present are far advanced to compete with many countries. However, many Korean cases still have displayed that the standard and the quality of conservation practice need to be improved. This research examined several cases of derelict restoration of metal relics executed by non-conservators and the effects of their ignorant use of irreversible materials on the valuable objects. The purpose of the study is to display the problem of such treatments and to suggest a need of framework to prevent the loss of original form from them. Metal Buddha statue (Cosmic Buddha) in Borim Temple (National Treasure No. 117), which was conserved by an unexperienced non-conservator, has suffered from a serious problem of corrosion because of the use of destructive material, iron chloride. Another case for metal Buddha statue in Dopian Temple (National Treasure No. 63) displays a representative example of using irreversible materials, Cashew and such ignorant application made a later conservation treatment so difficult in removing the material from the surface of the statue. In conclusion, the research argued that the understanding of materials used in the objects, and the value of relics is important, and pre-experiments before applying conservation materials to a valuable heritage are essential in the conservation treatment.

  • PDF

저온공정 n-InGaAs Schottky 접합의 구조적 특성 (Structural Analysis of Low Temperature Processed Schottky Contacts to n-InGaAs)

  • 이홍주
    • 한국전기전자재료학회논문지
    • /
    • 제14권7호
    • /
    • pp.533-538
    • /
    • 2001
  • The barrier height is found to increase from 0.25 to 0.690 eV for Schottky contacts on n-InGaAs using deposition of Ag on a substrate cooled to 77K(LT). Surface analysis leads to an interface model for the LT diode in which there are oxide compounds of In:O and As:O between the metal and semiconductor, leading to behavior as a metal-insulator-semiconductor diode. The metal film deposited t LT has a finer and more uniform structure, as revealed by scanning electron microscopy and in situ metal layer resistance measurement. This increased uniformity is an additional reason for the barrier height improvement. In contrast, the diodes formed at room temperature exhibit poorer performance due to an unpassivated surface and non-uniform metal coverage on a microscopic level.

  • PDF

베릴륨이 함유되지 않은 니켈-크롬 합금 코어와 코발트-크롬 합금 코어의 적합도 비교평가 (Comparison of the marginal and internal fit of cores fabricated by Ni-Cr alloy(non-beryllium) and Co-Cr alloy)

  • 김기백;김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.353-359
    • /
    • 2012
  • Purpose: The aim of this study measured and compared the marginal and internal fit of metal cores with two base metal alloy (Ni-Cr alloy(non-beryllium), Co-Cr alloy). Methods: Maxillary right first molar abutment fabricated by titanium was prepared for this study. Impressions(10ea) were made from titanium model, and study models were poured with improved dental stone. Wax cores of twenty were prepared for burn-out and casting. Ten wax cores cast Ni-Cr alloy(non-Be), and finally ten cast Co-Cr alloy. Marginal and internal fit of cores was evaluated using silicone replica technique and digital microscope(x160). The data were statistically analyzed with the independent samples t-test (${\alpha}$ <.05). Results: Mean(standard deviation, SD) marginal and internal fit total size of Ni-Cr alloy(non-Be) group was $73.3(14.4){\mu}m$ and of Co-Cr alloy group $65.6(17.4){\mu}m$. The marginal and internal fit total size of Ni-Cr alloy group(non-Be) was statistically significantly greater than that of Co-Cr alloy group (P=.004). Conclusion: Co-Cr alloy cores in this study had a better marginal fit than Ni-Cr alloy(non-Be) cores.

비접촉 생체신호 모니터링 응용을 위한 세라믹/메탈 할라이드 복합막 기반 습도센서 개발 (Development of Humidity Sensor Based on Ceramic/Metal Halide Composite Films for Non-Contact Biological Signal Monitoring Applications)

  • 박태웅;김익수;김민지;박철환;서의경;오종민
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.412-417
    • /
    • 2022
  • Capacitive-type humidity sensors with a high sensitivity and fast response/recovery times have attracted a great attention in non-contact respiration biological signal monitoring applications. However, complicated fabrication processes involving high-temperature heat treatment for the hygroscopic film is essential in the conventional ceramic-based humidity sensors. In this study, a non-toxic ceramic/metal halide (BaTiO3(BT)/NaCl) humidity sensor was prepared at room temperature using a solvent-free aerosol deposition process (AD) without any additional process. Currently prepared BT/NaCl humidity sensor shows an excellent sensitivity (245 pF/RH%) and superior response/recovery times (3s/4s) due to the NaCl ionization effect resulting in an immense interfacial polarization. Furthermore, the non-contact respiration signal variation using the BT/NaCl sensor was determined to be over 700% by maintaining the distance of 20 cm between the individual and the sensor. Through the AD-fabricated sensor in this study, we expect to develop a non-contact biological signal monitoring system that can be applied to various fields such as respiratory disease detection and management, infant respiratory signal observation, and touchless skin moisture sensing button.

The Origin of the Metal-insulator Transitions in Non-stoichiometric TlCu3-xS2 and α-BaCu2-xS2

  • Jung, Dong-woon;Choi, Hyun-Guk;Kim, Han-jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권3호
    • /
    • pp.363-367
    • /
    • 2006
  • The structure-property relations of ternary copper chalcogenides, $TlCu_{3-x}S_2$ and $\alpha-BaCu_{2-x}S_2$ are examined. The density of states, band dispersions, and Fermi surfaces of these compounds are investigated to verify the reason of the metal-insulator transitions by extended Huckel tight-binding band calculations. The origin of the metalinsulator transitions of non-stoichiometric $TlCu_{3-x}S_2$ and $\alpha-BaCu_{2-x}S_2$ is thought to be the electronic instability induced by their Fermi surface nesting.

정적 외연적 유한요소법을 이용한 비드공정해석 (The Analysis of Draw-bead Process by Using Static-explicit Finite Element Method)

  • 정동원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.604-609
    • /
    • 2001
  • In the sheet metal forming process, the drawbead is used to control the flow of material during the forming process. The drawbead provides proper restraining force to the material and prevents defects such as wrinkling or breakage. For these reasons, many studies for designing the effective drawbead have been conducted. For the analysis, the numerical method called the static-explicit finite element method was used. The finite element analysis code for this method has been developed and applied to the drawbead process problems. In result, convergence problem and computation time due to large non-linearity in the existing numerical analysis methods were no longer a critical problem. Futhermore, this approach could treat the contact friction problem easily by applying very small time intervals. It is expected that various results from the numerical analysis will give very useful information for the design of tools in sheet metal forming process.

  • PDF

고압용 다이아프램 압축기 및 체크 밸브의 2-way FSI 수치해석 (TWO-WAY F냐 simulation OF THE DIAPHRAGM COMPRESSOR AND NON-RETURN CHECK VALVE)

  • 최범석;윤현기;유일수;박무룡
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.86-92
    • /
    • 2010
  • A metal diaphragm compressor has been widely used for supplying a high pressures gas. This compressor mainly consists of gas oil space and metal diaphragm. Gas sucked in the gas space is compressed by an oscillating metal diaphragm existed between the gas and oil space. A non-return discharge and suction check-valve are components of the compressor that draw off the compressed oil and gas. Those components are self-actuated by differential pressures. Therefore, the rapid response and stable operating conditions are required. In the present study, to find out the dynamic behavior of the suction, discharge valve and diaphragm compressor, the unsteady flow field has been investigated numerically by using the unsteady two-way FSI (Fluid Structure Interaction) simulation method, $k-{\omega}$ turbulent model and mesh deformation.

  • PDF

접합실 높이변화에 따른 컨덴서 튜브 직접압출 공정 및 금형강도해석 (Die stress and Process of Analysis for Condenser Tube Extrusion according to Chamber Height)

  • 이정민;이상곤;김병민;조형호;조훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 제5회 압출 및 인발가공 심포지엄
    • /
    • pp.33-41
    • /
    • 2002
  • In case of hollow cylinder extrusion using porthole die, the effects of extrusion parameters-temperature, the speed of extrusion, the shape of the die and mandrel-on metal flow in porthole die extrusion of aluminum have been investigated. However, there have been few studies about condenser tube extruded by porthole die. This study was designed to evaluate metal flow, welding pressure, extrusion load, tendency of mandrel deflection according to variation of chamber length. in porthole die. Estimation was carried out using finite element method. Porthole die is analyzed in as non-steady state. Analytical results provide useful information the optimal design of porthole die.

  • PDF

Spectroscopic Studies of TP6F PI Switched by Hole-Injection

  • 이경재;임규욱;김동민;이문호;강태희;정석민
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.297-298
    • /
    • 2011
  • Metal/poly (4,4'-aminotriphen-ylene hexafluoroisopropylidenediphthalimide) (TP6F PI)/metal structure exhibited an electrically volatile phase transition with high (OFF) or low (ON) resistive states when voltage between electrodes swept. Here, we demonstrate a noble set-up in which holes are injected by photoelectron emission process during the voltage sweep instead of direct charge carrier injection via metal electrode, which enables direct investigation into changed electronic structures of TP6F PI both in ON and OFF states using photoemission spectroscopy methods. In the I-V measurement, TP6F PI shows a non-volatile behavior. In spectroscopic results, this non-volatile behavior is leaded from the structural modification of the O=C double bond in phthalimide of TP6F PI by hole injection.

  • PDF

Pd-based metallic membranes for hydrogen separation and production

  • Tosti, Silvano;Basile, Angelo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.25-28
    • /
    • 2003
  • Low cost composite metallic membranes for the hydrogen separation and production have been prepared by using thin Pd-Ag foils reinforced by metallic (stainless steel and nickel) structures. Especially, “supported membranes” have been obtained by a diffusion welding procedure in which Pd-Ag thin foils have been joined with perforated metals (nickel) and expanded metals (stainless steel): in these membranes the thin palladium foil assures both the high hydrogen permeability and the perm-selectivity while the metallic support provides the mechanical strength. A second studied method of producing "laminated membranes" consists of coating non-noble metal sheets with very thin palladium layers by diffusion welding and cold-rolling. Palladium thin coatings over these metals reduce the activation energy of the hydrogen adsorption process and make them permeable to the hydrogen. In this case, the dense non-noble metal has been used as a support structure of the thin Pd-Ag layers coated over its surfaces: a proper thickness of the metal assures the mechanical strength, the absence of defects (cracks, micro-holes) and the complete hydrogen selectivity of the membrane. membrane.

  • PDF