• Title/Summary/Keyword: non-isothermal

Search Result 281, Processing Time 0.021 seconds

The Froude Scaling Study on the Ventilation of Non-isothermal Concentrated Fume from the Semi-closed Space (반밀폐형 공간에서 비등온 고농도 연무의 배연산출량 산정을 위한 Froude 상사연구)

  • Chang, Hyuk-Sang;Choi, Byung-Il;Park, Jae-Cheul;Kim, Myung-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.877-885
    • /
    • 2005
  • The Froude scaling between the prototype and the model was tried to estimate the necessary ventilation rate for non-isothermal concentrated fume from the semi-closed inner space. Based on the non-dimensional similitude equations derived from the Zukoski plume rise analysis, the scaling experiments were done to verify the relationship of the non-dimensional energy release rate and the non-dimensional mass flow rate by using two different scaled volume models, model A ($1\;m{\times}1\;m{\times}1\;m$) and model B ($0.5\;m{\times}0.5\;m{\times}0.5\;m$). The experimental results showed that the theoretical similitude between the models is acceptable for the prediction of ventilation rate of the concentrated fume. The maximum energy release rate used for the experiments was $20\;kW/m^3$. In the experimental range, the similitude between the energy release rate and the ventilation mass flow rate was well defined and the necessary ventilation rates were 20-30% higher than the stoichiometric ventilation mass flow rate. Based on results of current study, the design of the local air ventilation system can be improved by correcting the effects of buoyancy and diffusion of the non-isothermal concentrated fume.

Loop-Mediated Isothermal Amplification for the Detection of Xanthomonas arboricola pv. pruni in Peaches

  • Li, Weilan;Lee, Seung-Yeol;Back, Chang-Gi;Ten, Leonid N.;Jung, Hee-Young
    • The Plant Pathology Journal
    • /
    • v.35 no.6
    • /
    • pp.635-643
    • /
    • 2019
  • To detect Xanthomonas arboricola pv. pruni, a loopmediated isothermal amplification (LAMP) detection method were developed. The LAMP assay was designed to test crude plant tissue without pre-extraction, or heating incubation, and without advanced analysis equipment. The LAMP primers were designed by targeting an ABC transporter ATP-binding protein, this primer set was tested using the genomic DNA of Xanthomonas and non-Xanthomonas strains, and a ladder product was generated from the genomic DNA of X. arboricola pv. pruni strain but not from 12 other Xanthomonas species strains and 6 strains of other genera. The LAMP conditions were checked with the healthy leaves of 31 peach varieties, and no reaction was detected using either the peach leaves or the peach DNA as a template. Furthermore, the high diagnostic accuracy of the LAMP method was confirmed with 13 X. arboricola pv. pruni strains isolated from various regions in Korea, with all samples exhibiting a positive reaction in LAMP assays. In particular, the LAMP method successfully detected the pathogen in diseased peach leaves and fruit in the field, and the LAMP conditions were proven to be a reliable diagnostic method for the specific detection and identification of X. arboricola pv. pruni in peach orchards.

Development of diagnostic method for human Astrovirus with rapid, specific and high sensitivity using loop-mediated isothermal amplification method

  • Lee, Jin-Young;Rho, Jae Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.1
    • /
    • pp.173-182
    • /
    • 2020
  • Human Astrovirus (HuAstV), known as a waterborne virus, is a group IV positive-sense single-stranded RNA that belongs to Astroviridae. The first outbreak of HuAstV was reported in England in 1975. HuAstV can exist not only among clinical patients but also in various water environments, such as water for agriculture and vegetables. For diagnosis of HuAstV from water samples, a polymerase chain reaction (PCR) system has been developed. However, the PCR-based diagnostic method has problems in field application, such as reaction time, sensitivity and specificity. For this reason, in this study we developed the loop-mediated isothermal amplification assay (LAMP) system, aimed specifically at HuAstV. Three prepared LAMP primer sets were tested by specificity, non-specificity and sensitivity; one LAMP primer set was selected with optimum reaction temperature. The developed LAMP primer set reaction conditions were confirmed at 62℃, and detection sensitivity was 1 fg/μL. In addition, restriction enzyme HaeIII (GG/CC) was introduced to confirm that the LAMP reaction was positive. As a result, selected LAMP primer set was 100 - 1000 times more specific, rapid, and sensitive than conventional-nested PCR methods. For verification of the developed LAMP assay, twenty samples of cDNA from groundwater samples were tested. We expect that the developed LAMP assay will be used to diagnose HuAstV from various samples.

Development of loop-mediated isothermal amplification method for the rapid and sensitive detection of bovine tuberculosis in Korea native cattle (한우 결핵의 신속 감별진단을 위한 등온증폭법 개발)

  • Hwang, Eun-Suk;Lee, Tae-Uk;Jung, Dae-Young;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2011
  • Loop-mediated isothermal amplification (LAMP) was developed to detect Mycobacterium tuberculosis complex (MTC) and non-tuberculous mycobacterium (NTM) genomic DNA in blood samples of Korea native cattle. A set of four primers, two outer and two inner, were designed from M. bovis and M. avium genomic DNA targeting the IS6110 and 16S rRNA gene, respectively. Based on 85 Intradermal Tuberculin Test (ITT) positive blood sample and using conventional PCR and LAMP, the agreement quotient (kappa), which measures agreement beyond chance were 0.93 (conventional PCR) and 0.97 (LAMP), respectively. The detection limit of the LAMP method was $2.0{\times}10^2$ copy/ml M. bovis and M. avium cells, compared to $2.0{\times}10^3$ copy/ml M. bovis and M. avium cells for conventional PCR. These results suggest that the LAMP is a powerful tool for rapid, sensitive, and practical detection of MTC and NTM in blood samples of Korea native cattle.

DENSITY STRUCTURE AND STABILITY OF THE SUBCOMPONENTS IN GIANT MOLECULAR CLOUD COMPLEXES

  • Yoo, Chin-Woo;Hong, Seung-Soo
    • Journal of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.33-49
    • /
    • 1986
  • Radial distribution of internal density has been determined for thirteen subclouds in the three giant molecular cloud complexes accompanying Mon OB1, Mon OB2 and CMa OB1 associations, We modeled their radial density structures with the density distribution of isothermal gas spheres. Most of the subclouds, nine out of the thirteen, are well described by isothermal spheres of single component; while the rest four require an additional component. Total mass and potential energy of each subcloud are also derived from the radial density structure; thermal energy and internal velocity dispersion required for sustaining the density structure are deduced from the isothermal gas model. Our derived masses of the clouds are comparable to the values determined by Blitz (1978) under LTE assumption. This agreement suggests that the correction factor for non-LTE effect on mass-estimate is not far from unity. The ratio of the gravitational potential energy to the kinetic energy of thermal motion is as large as 250; hence the thermal motion alone cannot support these clouds against the gravity. Being supported by turbulence motion with velocities of six to seven times the thermal velocity, the clouds of one-component type seem to be in equilibrium with the gravity; while the clouds of two-component type are likely to be in the stage of gravitational collapse.

  • PDF

Non-Invasive Colorimetric Magneto Loop-Mediated Isothermal Amplification (CM-LAMP) Method for Helicobacter pylori Detection

  • Bangpanwimon, Khotchawan;Mittraparp-arthorn, Pimonsri;Srinitiwarawong, Kanchana;Tansila, Natta
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.501-509
    • /
    • 2021
  • More than half the world's population is thought to be infected with Helicobacter pylori. Although the majority of infected people are asymptomatic, H. pylori infection may cause gastric ulcers and deadly gastric cancer. Owing to the difficulty and invasiveness of current routine culture and diagnostic methods, a highly sensitive and specific noninvasive assay for H. pylori is of interest. This study highlighted the design and performance of a colorimetric magneto loop-mediated isothermal amplification (CM-LAMP) assay to detect H. pylori in spiked saliva samples. LF primers were coated on magnetic nanoparticles by carbodiimide-induced immobilization and functionally used for solid-phase amplification. During the LAMP reaction at 66℃, biotin-tagged FIPs were incorporated into LAMP amplicons. The colorimetric signal developed after the addition of NeutrAvidin horseradish peroxidase conjugate (NA-HRP) and ABTS. None of the tested microorganisms, including closely related bacteria, was shown positive by the CM-LAMP assay except H. pylori isolates. This novel platform was highly specific and 100-fold more sensitive (40 CFU/ml or 0.2 CFU per reaction) than the PCR and conventional LAMP assays for the detection of H. pylori in spiked saliva. Our results demonstrated the feasibility of using this noninvasive molecular diagnostic test to detect H. pylori in saliva samples.

Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick

  • Liu, Zhi-Ke;Zhang, Qiu-Yu;Yang, Ning-Ning;Xu, Ming-Guo;Xu, Jin-Feng;Jing, Ming-Long;Wu, Wen-Xing;Lu, Ya-Dong;Shi, Feng;Chen, Chuang-Fu
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.3
    • /
    • pp.454-464
    • /
    • 2019
  • Salmonellosis is a highly contagious bacterial disease that threatens both human and poultry health. Tests that can detect Salmonella in the field are urgently required to facilitate disease control and for epidemiological investigations. Here, we combined loop-mediated isothermal amplification (LAMP) with a chromatographic lateral flow dipstick (LFD) to rapidly and accurately detect Salmonella. LAMP primers were designed to target the Salmonella invA gene. LAMP conditions were optimized by adjusting the ratio of inner to outer primers, $MgSO_4$ concentration, dNTP mix concentration, amplification temperature, and amplification time. We evaluated the specificity of our novel LAMP-LFD method using six Salmonella species and six related non-Salmonella strains. All six of the Salmonella strains, but none of the non-Salmonella strains, were amplified. LAMP-LFD was sensitive enough to detect concentrations of Salmonella enterica subsp. enterica serovar Pullorum genomic DNA as low as $89fg/{\mu}l$, which is 1,000 times more sensitive than conventional PCR. When artificially contaminated feed samples were analyzed, LAMP-LFD was also more sensitive than PCR. Finally, LAMP-LFD gave no false positives across 350 chicken anal swabs. Therefore, our novel LAMP-LFD assay was highly sensitive, specific, convenient, and fast, making it a valuable tool for the early diagnosis and monitoring of Salmonella infection in chickens.

Rapid and Visual Detection of Vibrio parahaemolyticus in Aquatic Foods Using blaCARB-17 Gene-Based Loop-Mediated Isothermal Amplification with Lateral Flow Dipstick (LAMP-LFD)

  • Hu, Yuan-qing;Huang, Xian-hui;Guo, Li-qing;Shen, Zi-chen;LV, Lin-xue;Li, Feng-xia;Zhou, Zan-hu;Zhang, Dan-feng
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.12
    • /
    • pp.1672-1683
    • /
    • 2021
  • Vibrio parahaemolyticus is recognized as one of the most important foodborne pathogens responsible for gastroenteritis in humans. The blaCARB-17 gene is an intrinsic β-lactamase gene and a novel species-specific genetic marker of V. parahaemolyticus. In this study, a loop-mediated isothermal amplification (LAMP) assay combined with a lateral flow dipstick (LFD) was developed targeting this blaCARB-17 gene. The specificity of LAMP-LFD was ascertained by detecting V. parahaemolyticus ATCC 17802 and seven other non-V. parahaemolyticus strains. Finally, the practicability of LAMP-LFD was confirmed by detection with V. parahaemolyticus-contaminated samples and natural food samples. The results showed that the optimized reaction parameters of LAMP are as follows: 2.4 mmol/l Mg2+, 0.96 mmol/l dNTPs, 4.8 U Bst DNA polymerase, and an 8:1 ratio of inner primer to outer primer, at 63℃ for 40 min. The optimized reaction time of the LFD assay is 60 min. Cross-reactivity analysis with the seven non-V. parahaemolyticus strains showed that LAMP-LFD was exclusively specific for V. parahaemolyticus. The detection limit of LAMP-LFD for V. parahaemolyticus genomic DNA was 2.1 × 10-4 ng/μl, corresponding to 630 fg/reaction and displaying a sensitivity that is 100-fold higher than that of conventional PCR. LAMP-LFD in a spiking study revealed a detection limit of approximately 6 CFU/ml, which was similar with conventional PCR. The developed LAMP-LFD specifically identified the 10 V. parahaemolyticus isolates from 30 seafood samples, suggesting that this LAMP-LFD may be a suitable diagnostic method for detecting V. parahaemolyticus in aquatic foods.

Flow analysis of non-isothermal three dimensional filling phase in injection molding and its application (사출성형에서의 비등온, 3차원 유동해서과 그 응용)

  • 김대업;정근섭;이귀영
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 1993
  • 사출성형 문제는 열전달과 유체유동이 복합된 문제라고 할수 있다. 사출성형 공정은 충진(filling), 보압(packing) 및 냉각과정(cooling phase)으로 이루어 진다. 충진과정은 높은 점성의 Non-Newtonian유체가 몰드내의 캐버티로 사출됨으로써 이루어지며 플라스틱의 점성도는 플라스틱의 온도 및 유동속도와 관련이 크며 이 flow-rate는 점도와 더불어 변화한다. CAE 유동해석 프로그램은 유체의 흐름과 열전달을 이용하여 충진과정을 이해하는데 이용되고 있다. 본 고에서는 사출성형 과정 중 충진과정에 대한 컴퓨터 시뮬레이션과 그 적용사례에 대하여 살펴본다.

  • PDF