• Title/Summary/Keyword: non vacuum

Search Result 631, Processing Time 0.028 seconds

Oxygen diffusion on W(110) : Comparison of experiment and theory (W(110)면에서의 산소의 확산 : 실험과 이론의 비교)

  • 남창우;홍진표;김채옥
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3A
    • /
    • pp.181-186
    • /
    • 1999
  • The diffusion of oxygen atoms on tungsten (110) surface is studied by comparison of experiment results and recent calculations. It has been suggested that the thermodynamic factor which is inversely proportional to be compressibility has strong temperature dependence which may cause non-Arrhenius behavior of diffusion coefficient. Recent experiments, however, indicate effectively no temperature dependence of this factor and support the view that non-Arrhenius behavior originates from the dynamic factor rather than the thermodynamic factor. Discrepancies in coverage dependence of physical quantities between theory and experiment are discussed.

  • PDF

A study on the Influence Affected on Injection Molding Product by Vacuum Degree (진공도가 사출성형제품에 미치는 영향에 관한 연구)

  • 이은종;신남호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.183-188
    • /
    • 2003
  • Non-molding and welding line happen by the assembly of gas at the connector terminal. There is not good phenomenon of burr by increasing the over injection pressure, the temperatures of die and resin to prevent from them. Therefore, the connector mold to apply the vacuum molding system is developed in this study. The vacuum pressure is controlled systematically with the optimum conditions in the important ingredients of injection molding that are the temperatures of melting resin and die and cooling condition. The badness in charging is cleared by making a vacuum to non-charging part of the deep bottom part of each cavity. And the vacuum system to reduce the cycle time is applied as the study envelopment of molding work. So, the good product and the productivity improvement can be obtained in this study.

  • PDF

Thermal analysis of a LH2 storage for vehicles (자동차용 액체수소 저장 용기의 열해석)

  • Oh, Byeong Soo;Jung, Jin Sam
    • Journal of Hydrogen and New Energy
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The development of hydrogen vehicles has been actively progressed in the developed countries such as U. S., Japan and Germany. The most important technology of using hydrogen fuel is to develope a compatible storage tank with respect to the fossil fuel tank. Among many storage methods, the liquid hydrogen is the most desirable state because of the lowest volume and weight. The metal hydride tank is too heavy and the compressed hydrogen tank is too bulky. Because of these reasons, it is the principal purpose to analyze the theoretical heat transfer for designing and manufacturing an actual $LH_2$ tank. The insulation methods of the room between inner and outer vessel are non-vacuum, vacuum, vacuum with MLI(Multi-Layer Insulation). According to the results of the numerically calculated heat leak through the walls of the $LH_2$ tank, the vacuum insulated tank has 20 times and the MLI tank has 5616 times less heat leak than the non-vacuum tank.

  • PDF

Effects of Vacuum Packaging on the Quality Characteristics of Frozen Tteokgalbi Made from Spent Laying Hen Meat and Mechanically Deboned Chicken Meat (산란 성계육과 기계발골 계육으로 제조된 냉동 떡갈비의 품질에 미치는 진공포장 효과)

  • Song, Gi-Chang;Kim, Hyeong-Jun;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.1
    • /
    • pp.17-26
    • /
    • 2018
  • This study aimed to investigate the effects of vacuum packaging on the quality characteristics of frozen Tteokgalbi made from spent laying hen meat and mechanically deboned chicken meat (MDCM). The samples were prepared with different levels of added MDCM; C (0%), T1 (20%), T2 (40%), and T3 (60%). The samples were allocated for microbiological and physico-chemical analyses after 0, 45, and 90 days at $-18^{\circ}C$, with or without vacuum packaging. After 90 days of storage, the values of volatile basic nitrogen were significantly lower in the vacuum packaged samples compared to the non-vacuum samples, irrespective of the added levels of MDCM (p<0.05). Sensory results at day 0 of storage showed that the texture scores of C and T1 samples were significantly higher than those of T2 and T3, while the flavor scores were the lowest for the T3 samples (p<0.05). In addition, with increased storage duration, the texture and flavor attributes of the vacuum-packaged samples were found to be higher than those of non-vacuum samples. In general, the vacuum-packaged samples tended to show superior physico-chemical quality characteristics compared to the non-vacuum samples, when the storage time was extended up to 90 days.

Calculation of non-condensable gases released in a seawater evaporating process (해수 증발과정에서의 기체방출량 계산)

  • Jeong, Kwang-Woon;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.182-190
    • /
    • 2017
  • All liquids contain a small amount of gaseous components and the amount of gases dissolved in a liquid is in accordance with Henry's Law. In a multi-stage thermal-type seawater desalination plant, as the supplied seawater undergoes variations in temperature and pressure in each evaporator, the gases dissolved in the seawater are discharged from the liquid. The discharged gases are carbon dioxide, nitrogen, oxygen, and argon, and these emitted gases are non-condensable. From the viewpoint of convective heat transfer, the evaluation of non-condensable gas released during a vacuum evaporation process is a very important design factor because the non-condensable gases degrade the performance of the cooler. Furthermore, in a thermal-type seawater desalination plant, most evaporators operate under vacuum, which maintained through vacuum system such as a steam ejector or a vacuum pump. Therefore, for the proper design of a vacuum system, estimating the non-condensable gases released from seawater is highly crucial. In the study, non-condensable gases released in a thermal-type seawater desalination plant were calculated quantitatively. The calculation results showed that the NCG releasing rate decreased as the stage comes getting a downstream and it was proportional to the freshwater production rate.

Non-polar and Semi-polar InGaN LED Growth on Sapphire Substrate

  • Nam, Ok-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.51-51
    • /
    • 2010
  • Group III-nitride semiconductors have been widely studied as the materials for growth of light emitting devices. Currently, GaN devices are predominantly grown in the (0001) c-plane orientation. However, in case of using polar substrate, an important physical problem of nitride semiconductors with the wurtzite crystal structure is their spontaneous electrical polarization. An alternative method of reducing polarization effects is to grow on non-polar planes or semi-polar planes. However, non-polar and semipolar GaN grown onto r-plane and m-plane sapphire, respectively, basically have numerous defects density compared with c-plane GaN. The purpose of our work is to reduce these defects in non-polar and semi-polar GaN and to fabricate high efficiency LED on non/semi-polar substrate. Non-polar and semi-polar GaN layers were grown onto patterned sapphire substrates (PSS) and nano-porous GaN/sapphire substrates, respectively. Using PSS with the hemispherical patterns, we could achieve high luminous intensity. In case of semi-polar GaN, photo-enhanced electrochemical etching (PEC) was applied to make porous GaN substrates, and semi-polar GaN was grown onto nano-porous substrates. Our results showed the improvement of device characteristics as well as micro-structural and optical properties of non-polar and semi-polar GaN. Patterning and nano-porous etching technologies will be promising for the fabrication of high efficiency non-polar and semi-polar InGaN LED on sapphire substrate.

  • PDF

Hydroxyl Radical Species Generated by Non-thermal Direct Plasma Jet and Their Qualitative Evaluation

  • Ghimire, B.;Hong, S.I.;Hong, Y.J.;Choi, E.H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.198.2-198.2
    • /
    • 2016
  • Reactive oxygen and nitrogen species (RONS) can be generated by using non-thermal atmospheric pressure plasma jet which have profound biomedical applications [1, 2]. In this work, reactive oxygen species like hydroxyl radical (OH) are generated by using non-thermal direct plasma jet above water surface using Ar gas and their properties have been studied using ultraviolet absorption spectroscopy. OH radicals are found to be generated simultaneously with the discharge current with concentration of $2.7{\times}1015/cm3$ at 7mm above water surface while their persistence time have been measured to be $2.8{\mu}S$. In addition, it has been shown that plasma initiated ultraviolets play a major role to generate RONS inside water. Further works are going on to measure the temporal behavior of OH and $O2^*-$.

  • PDF

The Efficiency of VAC(Vacuum-Assisted Closure) in Non-healing Wound (하지의 난치성 창상치유에 있어 VAC(Vacuum-Assisted Closure)의 유용성)

  • Park, Jung Min;Kwon, Yong Seok;Jung, Ki Hwan;Lee, Keun Cheol;Kim, Seok Kwun;An, Won Suk
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.727-732
    • /
    • 2005
  • The treatment of wounds of the lower extremity caused by diabetes or vascular dysfunction remains a difficult problem for the plastic surgeon. The use of negative pressure in wound healing is a relatively new method to facilitate chronic wound healing by secondary healing. The use of vacuum-assisted closure(VAC) system is purposed to reduce local edema, increase regional blood flow, enhance epithelial migration, preserve a moist wound environment, reduce bacterial colonization, promote granulation tissue formation, and mechanically enhance wound closure. The VAC also can be used as a dressing for anchoring an applied split thickness skin graft. We reviewed the data from 20 consecutive patients with non-healing wound in lower extremity at Dong-A University from March 2002 to December 2004. We used the VAC in 20 patients and compared the results with the control group. In the VAC using group, mean application duration was about 3 weeks and dressing change was done every other day. The follow-up period of patients ranged from 3 months to 30 months with a mean of 17 months. The points of comparison with control group are wound size, granulation tissue proliferation rate, operation method, preoperative time, postoperative healing time, complication, and cost. With those points, we propose to approve the efficiency of the VAC in non-healing wound. As a result, the VAC used in non-healing wound decrease wound size, accelerate granulation tissue formation, do a wound closure with less invasive operation method, make less postoperative complication, can make operation time shorter. Therefore it is cost effect. Our results demonstrate the usefulness of VAC as an adjunct in management of chronic wounds with other extrinsic factors.

Electrical Characteristics of Flat Cesium Antimonide Photocathode Emitters in Panel Devices

  • Jeong, Hyo-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.5
    • /
    • pp.306-309
    • /
    • 2016
  • The Cs3Sb photocathode was formed by non-vacuum process technology. An in-situ vacuum device was fabricated successively with flat cesium antimonide photocathode emitters fabricated in a process chamber. The electrical properties of the device were characterized. Electron emission from the devices was induced by photoemitted electrons, which were accelerated by an anode electric field that was shielded from the photoemitter surface. The electrical characteristics of the devices were investigated by measuring the anode current as a function of device operation times with respect to applied anode voltages. Planar blue LED light with a 450 nm wavelength was used as an excitation source. The results showed that the cesium antimonide photocathode emitter has the potential of long lifetime with stable electron emission characteristics in panel devices. These features demonstrate that the cesium antimony photocathodes produced by non-vacuum processing technology is suitable for flat cathodes in panel device applications.

Enhancement in quantum noise correlation between the two outputs of a nondegenerate optical amplifier with a non-vacuum state idler input

  • Kim, Chong-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.1-4
    • /
    • 1997
  • The theoretical limit of the noise correlation between the signal and idler outputs of a nondegenerate optical parametric amplifier (NOPA) with a coherent state signal and vacuum state idler input can be enhanced if a non-vacuum coherent state idler input is employed. By choosing a balanced signal and idler input, the noise correlation is $1/{({\root}g + {\root}{g-1})}^2$, where g is the intensity gain of the NOPA, and that is superior to the prediced outputs with single signal input by approximately 3dB. The result is applicable to all the schemes that use the NOPA to produce a sub-shot noise light generation such as feed-back or feed-forward control.