• Title/Summary/Keyword: noise power spectrum

Search Result 449, Processing Time 0.022 seconds

Comparison test for PD measuring about UHF-sensor and HFCT-sensor in cable joint-box of MV grade (MV급 케이블 중간접속부의 PD 측정을 위한 UHF-센서와 HFCT-센서의 비교시험)

  • Shin, Dong-Hoon;Lee, Yong-Sung;Kim, Jung-Yoon;Yang, Jong-Seok;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1511-1512
    • /
    • 2006
  • In this paper, we measured PD signals from artificial surface defects and corona discharges under laboratory circumstances like the fields using both HFCT-sensor and UHF-sensor for MV grade XLPE cable with AMP, spectrum analyzer and oscilloscope. Also, detected signals were analyzed via PRPDA system in this paper. As a result, in this case of HFCT-sensor, the amount of background noise are larger than as compared to UHF-sensor. There is needed some hardware or software or software algorithm removing background noise effectively for diagnosis the underground power transmission cable in the case of HFCT-sensor.

  • PDF

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

The Higher-Order-Modulated Slow-Frequency-Hopping Spread-Spectrum System over AWGN under Partial-Band Jamming (부분 대역 재밍 하에서의 가산성 백색 가우시안 잡음 채널에서 고차 변조의 저속 주파수 도약 대역 확산 시스템)

  • Ahn, Hyoungbae;Kim, Chanki;No, Jong-Seon;Park, Jinsoo;Song, Hong-Yeop;Han, Sung Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.14-24
    • /
    • 2017
  • In this paper, we propose a new EIM(erasure insertion method) based on the average-minimal-noise-power for HOM(higher order modulation) over AWGN(additive white Gaussian noise) under PBJ(partial-band jamming). Then we design SFH/SS(slow-frequency-hopping spread-spectrum) system by applying this method and formulate the PER(packet error rate) of the system. Based on this formula, we propose a new method to set the optimal threshold of the EIM and verify it at the designed 16-QAM SFH/SS system.

Analysis of acoustic emission signals during fatigue testing of a M36 bolt using the Hilbert-Huang spectrum

  • Leaman, Felix;Herz, Aljoscha;Brinnel, Victoria;Baltes, Ralph;Clausen, Elisabeth
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.1
    • /
    • pp.13-25
    • /
    • 2020
  • One of the most important aspects in structural health monitoring is the detection of fatigue damage. Structural components such as heavy-duty bolts work under high dynamic loads, and thus are prone to accumulate fatigue damage and cracks may originate. Those heavy-duty bolts are used, for example, in wind power generation and mining equipment. Therefore, the investigation of new and more effective monitoring technologies attracts a great interest. In this study the acoustic emission (AE) technology was employed to detect incipient damage during fatigue testing of a M36 bolt. Initial results showed that the AE signals have a high level of background noise due to how the load is applied by the fatigue testing machine. Thus, an advanced signal processing method in the time-frequency domain, the Hilbert-Huang Spectrum (HHS), was applied to reveal AE components buried in background noise in form of high-frequency peaks that can be associated with damage progression. Accordingly, the main contribution of the present study is providing insights regarding the detection of incipient damage during fatigue testing using AE signals and providing recommendations for further research.

Determination of Shock Response Spectrum Using FRF of Statistical Energy Analysis Method (통계적 에너지 분석법의 FRF를 이용한 충격 응답 스텍트럼(SRS)의 결정)

  • 구성완;황철규;김인성
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.551-560
    • /
    • 2004
  • A method how to determine the shock response spectrum from the FRF of the statistical energy analysis( SEA ) is presented here. The system of 3 different Plates connected by bolt joints is selected simulating missile structural sections Joined together. First, the SEA model was rendered by SEA parameters which were determined from experimental SEA method. Then, the mobility power was input to the SEA model and we can verify the validity of the model in the medium to high frequency range checking the reproduction of output average velocity. And, the shock induced shock response spectrum(SRS) was obtained using SEA FRF and arbitrarily chosen experimental FRF. We have compared the thus obtained SRS with actually measured SRS and they were relatively in good agreement. In this paper, we used the measured SEA FRF and therefore we have got the SRS well agreed with actually measured SHS even in the low frequency range. If the SEA FRF of well verified SEA model is used, the good result will come out in SEA effective frequency range which is more important at SRS.

Acoustical Similarity for Small Cooling Fans Revisited (소형 송풍기 소음의 음향학적 상사성에 관한 연구)

  • 김용철;진성훈;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF

Assessment of dose effects on image quality at chest computed radiography (흉부 CR 영상에서 선량이 화질에 미치는 영향에 대한 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.421-426
    • /
    • 2011
  • This research was accomplished to assess dose effects on image quality at computed radiography (CR). The ultimate target of the research was finding optimized exposure that provides necessary image quality for the clinical chest diagnosis. Modulation transfer function (MTF), normalized noise power spectrum (NNPS), and Noise equivalent quanta (NEQ) corresponding to the different doses were measured for the assessment of image quality. The preparation of "edge test device" used in MTF measurement and experimental geometry setup were followed by the recommendations of International Electrotechnical Commission (IEC). The experimental results show the necessary image quality can be achieved even at a half of the automatic exposure control (AEC) setting dose for chest diagnosis. It means that the patient exposure can be reduced dramatically by using optimized dose.

Image Restoration Simulation of Digital X-ray Images Based upon Filtering Techniques and the Quality Evaluation of the Restored Images (다양한 필터링 기법을 이용한 디지털 X-선 영상복원 시뮬레이션 및 정량적 화질평가)

  • Lee, So-Young;Choi, Sung-Il;Oh, Ji-Eun;Cho, Hee-Moon;Lee, Sung-Ju;Park, Yeon-Ok;Cho, Hyo-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.33-40
    • /
    • 2008
  • Images acquired by a digital X-ray imaging system are inherently degraded due to system degradation process and additive noise sources. The system degradation in image quality is typically described as the system response function characterized by the modulation transfer function (MTF) and the noise term described as the noise power spectrum (NPS). In this case, we can restore the blur image as close as possible to the original image by using modified filtering designed for digital imaging system, as we know more precisely about the MTF and the NPS. In this paper, by performing simulation, we tried to restore blurred images taken from a digital X-ray imaging system based upon conventional filtering techniques such as a direct-inverse filtering, limited-inverse filtering, or a Wiener filtering, and evaluated the characteristics of the image restoration.

  • PDF

A Study on Characteristic of Image Quality according to CT Table Height in Computed Tomography (컴퓨터단층촬영 검사 시 테이블 높이에 따른 화질 특성에 관한 연구)

  • Ki-Won Kim;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Ki-Jong Lee;Han-Sol Park;Joo-Young Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.295-301
    • /
    • 2023
  • In addition to protocol adjustments during CT examinations, the height of the CT table can also affect image quality. Therefore, this study aimed to investigate the change in image quality depending on the height of the table in brain CT, which accounts for a large proportion of CT examinations, by measuring signal to contrast to noise ratio (CNR) and noise power spectrum (NPS) using the head phantom and evaluating them. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. The CNR result showed the highest value at 965 mm, which is the height adjacent to the center of the head phantom. NPS showed the lowest NPS at 915 mm, the center of the head phantom in the low frequency region. From these results, it can be seen that the height of the table in CT examination is closely related to the image quality, and it can be seen the characteristics of image quality according to CT table through quantitative evaluation methods such as CNR and NPS.

우리나라 실정에 알맞는 위성통신 시스템에 관한 연구

  • 강영흥;조성언;고봉진;조성준;김원후
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.10
    • /
    • pp.868-878
    • /
    • 1990
  • Upon introducing satellite communication system to Korea, one of the important problems to cope with is the effect from the probable intentional interference I.e. jamming. In this paper we have investigated how much the performance of ordinary PSK signal and Directed Sequence Spread Spectrum PSK signal degrade by the effect of jamming in the satellite communication system. In analysis we have consider the M ary PSK signal and the liniter type nonlinear satellite transponder in an environment of uplink tone or noise jamming plus Gaussian noise and downlink Gaussian noise. Using the derived error rate equation we have evaluated the error performance of BPSK and QPSK systems and compared this with that of DS BPSK system. Form the results, we know that the nonlinear satellite system is degraded more severely by the effect of noise jamming than tone jamming and the effect of tone jamming on the error rate performance can be reduced more remarkably by increasing the process gain in DS BPSK system rather than increasing carrier to jamming noise power ratio in conventional BPSK system.

  • PDF