• 제목/요약/키워드: newtonian flow

검색결과 326건 처리시간 0.025초

Numerical study of the effects of periodic body acceleration (PGZ) and bifurcation angle in the stenosed artery bifurcation

  • Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • 제21권3호
    • /
    • pp.175-183
    • /
    • 2009
  • This article describes the numerical investigation of blood flow in the stenosed artery bifurcation with acceleration of the human body. Using the commercial software FLUENT, three-dimensional analyses were performed for six simulation cases with different body accelerations and bifurcation angles. The blood flow was considered to be pulsation flow, and the blood was considered to be a non-Newtonian fluid based on the Carreau viscosity model. In order to consider periodic body acceleration, a modified, time-dependent, gravitational-force term was used in the momentum equation. As a result, flow variables, such as flow rate and wall shear stress, increase with body acceleration and decrease with bifurcation angle. High values of body acceleration generate back flow during the diastolic period, which increases flow fluctuation and the oscillatory shear index at the stenosis.

선인장 형태의 한국형 인공심장 내 3차원 혈류의 수치적 해석 (Numerical analysis of blood flow in the cactus type KTAH)

  • 박명수;고형종;민병구;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.695-696
    • /
    • 2002
  • Three-dimensional blood flow in the sac of the KTAH(Korean total artificial heart) is simulated using fluid-structure interaction model. The aim of this study is to delineate the three-dimensional unsteady-blood flow in the sac of KTAH. Incompressible viscous flow is assumed for blood using the assumption of Newtonian fluid. The numerical method employed in this study is the finite element software called ADINA. Fluid-structure interaction model between blood and sac is utilized to represent the deformation of the sac by the rigid moving actuator. Three-dimensional geometry of cactus type KTAH is chosen for numerical model with prescribed pressure boundary condition on the sac surface. Blood flow is generated by the motion of moving actuator and strongly interacts with the solid material surrounding blood. High shear stress is observed mainly near the inlet and outlet of the sac.

  • PDF

부력의 영향을 포함한 점탄성 유체의 열전달에 관한 수치해석 (Numerical Analysis on Heat Transfer of Viscoelastic Fluid including Buoyancy Effect)

  • 손창현;안성태;장재환
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.495-503
    • /
    • 2000
  • The present numerical study investigates flow characteristics and heat transfer enhancement of the viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. The combined effect of temperature-dependent viscosity, buoyancy and secondary flow caused by second normal stress difference are all considered. The Reiner-Rivlin model is used as a viscoelastic fluid model to simulate the secondary flow and temperature-dependent viscosity model is adopted. Three types of thermal boundary conditions involving different combinations of heated walls and adiabatic walls are considered in this study. Calculated Nusselt numbers are in good agreement with experimental results in both the thermal developing and thermally developed regions. The heat transfer enhancement can be explained by the combined viscoelasticity-driven secondary flow, buoyancy-induced secondary flow and temperature-dependent viscosity.

TPLS 혈액주머니 내의 3차원 비정상유동에 대한 수치해석 연구: 액추에이터 속도의 영향 (Numerical Study of 3D Unsteady Flow in a Blood Sac of TPLS: Effect of Actuator Speed)

  • 정기석;성현찬;박명수;고형종;심은보;민병구;박찬영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.206-211
    • /
    • 2003
  • This paper reports the numerical results for blood flow of the sac squeezed by moving actuator in the TPLS(Twin Pulse Life Support System). Blood flow in the sac is assumed to be 3-dimensional unsteady newtonian fluid. where the blood flow interacts with the sac, which is activated by the moving actuator. The flow field is simulated numerically by using the FEM code, ADINA. It is well known that hemolysis is closely related to shear stress acted on blood flow. According to this fact, we simulate four models with different speed for moving actuator and examine the distribution of shear stress for each model. Numerical results show that maximum shear stress is strongly dependent on the actuator speed.

  • PDF

안쪽축이 회전하는 동심환형관내 고-액 2상 유동연구 (Solid-liquid 2phase flow in a concentric annulus with rotation of the inner cylinder)

  • 김영주;한상목;우남섭;황영규
    • 에너지공학
    • /
    • 제18권2호
    • /
    • pp.87-92
    • /
    • 2009
  • 본 논문은 안쪽축이 회전하는 동심환형관 물과 비뉴튼유체의 고-액 2상 유동연구를 수행하였다. 점탄성유체의 유변학은 굴착구멍의 청결, 입자의 밖으로 수송하는 등 여러 가지 응용에 중요하다. 연구에서 투명한 아크릴관은 고체입자의 이동을 관찰하기 위하여 사용하였다. 환형관 속도는 0.3m/s에서 2.0m/s로 변한다. 머드시스템은 물과 CMC 수용액을 혼합하여 사용하였다. 연구에서 고려된 주요 변수들은 축회전속도, 유체 유동영역과 입자 주입율이다. 입자이송속도와 압력강하는 유체유량(Q, LPM)이 5~30의 범위에서 측정하였다. 물과 0.2% CMC 수용액에서 고체입자의 농도가 높을수록 압력손실이 커짐을 알 수 있었다.

점탄성유체의 저항 및 열전달 감소현상과 퇴화의 영향에 관한 연구 (A Study on the Drag and Heat Transfer Reduction Phenomena and Degradation Effects of the Viscoelastic Fluids)

  • 엄정섭;전찬열;유상신
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.37-48
    • /
    • 1990
  • The drag and heat transfer reduction phenomena and degradation effects of drag reducing polymer solutions which are known as the viscoelastic fluids are investigated experimentally for the turbulent circular tube flows. Two stainless steel tubes are used for the experimental flow loops. Aqueous solutions of Polyacrylamide Separan AP-273 with concentrations from 300 to 1000 wppm are used as working fluids. Flow loops are set up to measure the friction factors and heat transfer coefficients of test tubes in the once-through system and the recirculating flow system. Test tubes are heated by power supply directly to apply constant heat flux boundary conditions on the wall. Capillary tube viscometer and falling ball viscometer are used to measure the viscous characteristics of fluids and the characteristic relaxation time of a fluid is determined by the Powell-Eyring model. The order of magnidude of the thermal entrance length of a drag reducing polymer solution is close to the order of magnitude of the laminar entrance length of Newtonian fluids. Dimensionless heat transfer coefficients of the viscoelastic non-Newtonian fluids may be represented as a function of flow behavior index n and newly defined viscoelastic Graetz number. As degradation continues viscosity and the characteristic relaxation time of the testing fluids decrease and heat transfer coefficients increase. The characteristic relaxation time is used to define the Weissenberg number and variations of friction factors and heat transfer coefficients due to degradation are presented in terms of the Weissenberg number.

  • PDF

복부대동맥 분기관에서의 벽면전단응력 분포 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향 (Wall Shear Stress Distribution in the Abdominal Aortic Bifurcation : Influence of wall Motion, Impedance Phase Angle, and non-Newtonian fluid)

  • 최주환;김찬중;이종선
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권3호
    • /
    • pp.261-271
    • /
    • 2000
  • 벽면운동(wall motion)과 임피던스 페이즈앵글(impedance phase angle; 압력파와 유랑파 기아의 위상차)을 고려하여 맥동유동하에 있는 복부대동맥 분기관모델에서 2차원 전산유체해석을 수행하였다. 해석결과 분기광 근처에서응 전단응력의 크기가 매우 급격한 변화를 보임을 관찰하였고 벽면운동은 전단응력의 진폭을 감소시키는 효과를 가져왔다. 임피던스 페이즈 앵글이 음의 값을 향해 갈수록 시간 평균된 벽면 전단응력(mean wall shear stress)의 값은 감소하였으나 진폭(amplitude of wall shear stress)은 오히려 증가하였다. 페이즈앵글의 영향은 평균 벽면전단응력이 영에 근접하는 외벽(outer wall or lateral wall)의 바같쪽으로 휘어지는 부분(curvature site)에서 상대적으로 크게 나타났는데 $-90^{\circ}$ 페이즈앵글(혈류파가 혈압파를 1/4주기 앞서는 경우)일 경우에 $0^{\circ}$의 경우에 비해 평균은 $50\%$정도 감소하였고 진폭은 $15\%$정도의 상승를 나타내었다. 그러므로 고혈압 환자와 같이 큰 음의 페이즈앵글을 갖는 경우, 벽면전단응력의 평균은 낮아지고 시간에 따라 변화량(진폭)은 증가하므로 low and oscillatory wall shear stress 이론에 의하면 동맥경화에 더 민감하게 된다. 비뉴턴유체로 모델링한 경우에는 뉴턴유체의 경우에 비해 벽면전단응력의 평균값이 증가하므로서 동맥경화에 덜 민감하게 된다.

  • PDF

단축 스크류 압출기 내의 비뉴턴유체에 대한 3차원 열 및 유동해석 (Three-Dimensional Heat and Fluid Flow Simulations for Non-Newtonian Fluid in a Single Screw Extruder)

  • 곽동성;김우승;류민영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.337-342
    • /
    • 2001
  • A numerical study of three-dimensional fluid flow and heat transfer in the metering section of a single screw extruder has been performed. The mathematical model for the screw channel is simplified by unwound channel and fixing the coordinate system to the screw. The pressure boundary and the prescribed mass flow rate conditions are imposed on the inlet and outlet, respectively. The commercial code STAR-CD based on the finite volume method is used to obtain the results of the present work. The computation of the reverse flow, which cannot be computed by the marching-type 3-D model, is performed in the present study.

  • PDF

Element-free simulation of dilute polymeric flows using Brownian Configuration Fields

  • Tran-Canh, D.;Tran-Cong, T.
    • Korea-Australia Rheology Journal
    • /
    • 제16권1호
    • /
    • pp.1-15
    • /
    • 2004
  • The computation of viscoelastic flow using neural networks and stochastic simulation (CVFNNSS) is developed from the point of view of Eulerian CONNFFESSIT (calculation of non-Newtonian flows: finite elements and stochastic simulation techniques). The present method is based on the combination of radial basis function networks (RBFNs) and Brownian configuration fields (BCFs) where the stress is computed from an ensemble of continuous configuration fields instead of convecting discrete particles, and the velocity field is determined by solving the conservation equations for mass and momentum with a finite point method based on RBFNs. The method does not require any kind of element-type discretisation of the analysis domain. The method is verified and its capability is demonstrated with the start-up planar Couette flow, the Poiseuille flow and the lid driven cavity flow of Hookean and FENE model materials.

동심원통속의 Coutte flow에 있어서 비 Newton 유체의 유동특성 (A flow characteristic of non-newtonian fluid in coutte flow of concentric cylinder)

  • 권혁칠;이성노;부전유사
    • 오토저널
    • /
    • 제14권3호
    • /
    • pp.109-114
    • /
    • 1992
  • The purpose of this study is to experimentally research the effects of polymer additives on turbulent transition of Couette flow between concentric cylinders when outer one is rotating and inner one is at rest; the diameter ratio being 0.2. Aqueous polymer solution generate the degradation phenomena in machine forming work, but this is not effected in about 10 minute at 5ppm. aqueous polymer solution testing. The Reynolds number, referred to the gap distance and rotation velocity of the outer cylinder, of turbulent transition is about 20000 for water flow. In the laminer region, the torque value is as same as theoretical one in the region of low Reynolds number, but becomes high with an increase in the Reynolds number. The polymer additives reduce the Reynolds number for turbulent transtition. In the turbulent region, the torque is remarkably reduced by the polymer additives, soluble polymer take down effect of turbulent transition boundary torque.

  • PDF