• 제목/요약/키워드: neutron activation analysis

검색결과 183건 처리시간 0.024초

기기중성자방사화분석을 이용한 대전 3, 4 공단지역의 호흡성입자의 특성 (Characteristics of Respirable Particulate Matter from the Third and Fourth Industrial Complex Area of Daejeon City Using Instrumental Neutron Activation Analysis)

  • 임종명;이진홍
    • 환경영향평가
    • /
    • 제15권6호
    • /
    • pp.425-433
    • /
    • 2006
  • Instrumental neutron activation analysis was used to measure the concentrations of 27 elements associated with respirable particulate matter (PM10) that were collected from the Third and Fourth Industrial Complex Area of Daejeon City. The distribution patterns of elements were clearly distinguished with their concentrations varying across more than four orders of magnitude. The mean for Al were recorded to be the highest value of 1,527 $ng/m^3$, while that for In showed the lowest value of 0.1 $ng/m^3$. If compared in terms of enrichment factors, it was found that certain elements (e.g., As, Br, Cl, Cr, I, In, Sb, Se, and Zn) are enriched in PM10 samples of the study site. The results of factor analysis indicated six factors with statistical significance, which may exert dominant controls on regulating the elemental concentration levels in the study area.

의료용 선형가속기 차폐 재질로써 일반 콘크리트와 저 방사화 콘크리트 비교 (Comparison of General Concrete and Low-radiation Concrete as Shielding Materials for Medical Linear Accelerators)

  • 이동연;김정훈
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.45-53
    • /
    • 2019
  • 본 연구는 의료용 선형가속기 시설을 차폐하는 콘크리트에 대한 중성자 방사화 연구로써, 일반 콘크리트와 저 방사화 콘크리트를 비교 분석하였다. 실험 방법은 MCNPX (Ver. 2.5.0)와 FISPACT-2010를 사용하여 모의실험을 진행하여, 광자선과 중성자선에 대한 차폐능을 산정하고 중성자 방사화 평가를 진행하였다. 그 결과 차폐능은 일반 콘크리트에서 20~50 cm 효율적이였으며, 방사화 평가의 경우 저 방사화 콘크리트에서 방사능이 낮게 계산되었으나, 모두 자체처분허용 농도를 초과하지 않는 수준으로 산정되었다. 이를 종합적으로 분석한 결과 일반 콘크리트를 사용하는 것이 효율적인 것으로 판단된다.

Copper Salts in the Post-metallization of Non-genotoxic Direct Dyes

  • Bae, Jin-Seok;Freeman, Harold S.
    • Fibers and Polymers
    • /
    • 제3권4호
    • /
    • pp.147-152
    • /
    • 2002
  • Copper (II) salts are used as metallizing agents in the synthesis of new non-genotoxic direct dyes for cotton. Specifically, cotton fabric is dyed with non-genotoxic disazo direct dyes and then treated with copper salts. The complexes are characterized by neutron activation analysis, absorption spectrometry and standard Salmonella mammalian mutagenicity assay, and the after-treated fabrics are evaluated for lightfastness and washfastness. Direct dyes possessing ortho-propoxy and ortho'-hydroxy substituted systems formed the corresponding nonmutagenic 1:2 dye:metal complex and undergo significant improvement in lightfastness following metallization.

중성자 방사화분석에 의한 한국산 고전(古錢)의 분류 (A Classification of Korean Ancient Coins by Neutron Activation Analysis)

  • 전권수;이철;강형태;이종두
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.293-299
    • /
    • 1994
  • 조선시대에 주조된 고전(古錢) 시료 50개를 입수하여 그 속에 함유된 11종의 원소(Sn, Fe, As, Au, Ag, Co, Sb, Ir, Os, Ru, Ni)는 파괴 및 비파괴 중성자방사화분석으로, 3종 원소(Cu, Pb, Zn)는 원자흡수분광분석법으로 각각 정량하였다. 이들 15종의 분석 데이터를 사용하여 주성분분석법으로 각 시료를 고유 벡터 평면에 나타내었다. 시료끼리 군의 형성 및 군과 군 사이의 분리는 어떤 원소들이 동일한 근원을 가짐에 기인함을 알게 되었다.

  • PDF

試金工程中의 金의 熱中性子에 依한 放射化分析 (The Determination of Gold in Assay Process by Thermal Neutron Activation Analysis)

  • 김재일;김종국;장원표
    • 대한화학회지
    • /
    • 제7권2호
    • /
    • pp.165-169
    • /
    • 1963
  • 시금공정의 시료중의 금의 정성 및 정량을 열중성자에 의한 방사화분석으로 조사하였다. 회수률은 81.0∼93.6%이고 결과는 재현성이 좋았다. 정양적 결과는 ${\gamma}$-Spectrometric photopeak-area counting으로 얻었으며 속중성자반응으로 인한 간섭은 무시할 수 있었다.

  • PDF

4.2分의 短壽命 Thallium-206의 放射化分析 (Activation-Analysis of trace Thallium in Meteorites, Rocks, Minerals, Alloys, and Biological Samples using 4.2-Minute Thallium-206)

  • 김종국
    • 대한화학회지
    • /
    • 제5권1호
    • /
    • pp.26-28
    • /
    • 1961
  • Microgram quantities of thallirum in meteorites, rocks, minerals, alloys and biological samples have been analyzed by rapid neutron activation analysis. A l0-minute radiochemical separation procedure coupled with a gas-flow proportional detector for 4.2-minute half life measurement and a gamma or beta scintillation detector placed in close proximity to the sample permitted detection of the 4.2-min Tl206. Samples were irradiated for 10-minutes at a thermal neutron flux of approximately $0.95{\times}10^{11}$ neutron-$cm^{-2}-sec^{-1}.$ The low limits of detection was about $10^{-7}$ gm of thallium.

  • PDF

중성자 방사화분석법을 이용한 대기분진시료의 정량 (Determination of Trace Elements in Airborne Particulates by Instrumental Neutron Activation Analysis)

  • Chung, Yong-Sam;Chung, Young-Ju;Jeong, Eui-Sik;Cho, Seung-Yeon
    • Nuclear Engineering and Technology
    • /
    • 제27권2호
    • /
    • pp.234-247
    • /
    • 1995
  • Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis (INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux 1$\times$10$^{13}$ n/$\textrm{cm}^2$.s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 ore chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different counties. In the analytical result of two or both of standard reference materials, relative standard deviation wes within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at too different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources.

  • PDF

Determining PGAA collimator plug design using Monte Carlo simulation

  • Jalil, A.;Chetaine, A.;Amsil, H.;Embarch, K.;Benchrif, A.;Laraki, K.;Marah, H.
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.942-948
    • /
    • 2021
  • The aim of this work is to help inform the decision for choosing a convenient material for the PGAA (Prompt Gamma Activation Analysis) collimator plug to be installed at the tangential channel of the Moroccan Triga Mark II Research Reactor. Two families of materials are usually used for collimator construction: a mixture of high-density polyethylene (HDPE) with boron, which is commonly used to moderate and absorb neutrons, and heavy materials, either for gamma absorption or for fast neutron absorption. An investigation of two different collimator designs was performed using N-Particle Monte Carlo MCNP6.2 code with the ENDF/B-VII.1 and MCLIP84 libraries. For each design, carbon steel and lead materials were used separately as collimator heavy materials. The performed study focused on both the impact on neutron beam quality and the neutron-gamma background at the exit of the collimator beam tube. An analysis and assessment of the principal findings is presented in this paper, as well as recommendations.

Measurement of the Elemental Composition in Airborne Particulate Matter Using Instrumental Neutron Activation Analys

  • Chung, Yong-Sam;Lim, Jong-Myoung;Moon, Jong-Hwa;Kim, Sun-Ha;Cho, Hyun-Je;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.450-459
    • /
    • 2004
  • For the evaluation of emission sources by air sampling, airborne particulate matter for fine (<2.5 ${\mu}m2$ EAD : $PM_{2.5}$) and coarse partical (2.5-10 ${\mu}m2$ EAD : $PM_{2.5-10}$ fractions were collected using a Gent stacked filter unit low volume sampler and two types of polycarbonate filters. Air samples were collected twice monthly at two regions in and around Daejeon city in the Republic of Korea from January to December 2002. Monthly mass concentration of $PM_{2.5}$ and $PM_{2.5-10}$ were measured and the concentrations of 10 marker elements (Al, Sc, Ti ; Na, Cl ; As, V. Sb, Br, Se) were determined by an instrumental neutron activation analysis. Analytical quality control was corried out using certified reference materials. Enrichment factors were also calculated from the monitoring data to classify the anthropogenic and crustal origins.