• Title/Summary/Keyword: neutral response

Search Result 243, Processing Time 0.028 seconds

Lipophilic Crown-4 Derivatives as Lithium Ionophores for Lithium Ion Selective Liquid Membrane Electrodes

  • Jae Sang Kim;Sung Ouk Jung;Shim Sung Lee;Si-Joong Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.123-127
    • /
    • 1993
  • New lipophilic Crown-4 compounds of 16-membered rings containing furan (neutral carrier,I), tetrahydrofuran (neutral carrier,II) and lithium complex of the latter (neutral carrier,III) have been synthesized and tested as the active sensors for lithium ion in poly(vinyl chloride) (PVC) membrane electrode, in the presence and absence of an anion excluder, tetrakis(4-chloro-phenyl)borate (KTClPB), 2-nitrophenyl phenyl ether (NPPE), tris(2-ethylhexyl)phosphate (TEHP), o-nitrophenyl octyl ether (NPOE), dioctyl adipate (DOA), bis(2-ethylhexyl)adipate (BEHA), di-n-octylphenyl phosphonate (DOPP) were used as plasticizing solvent mediators. The electrode response function had a nearly Nernstian slope of 54-61 mV per decade (25$^{\circ}$C) within the concentration range of $10^{-1}-10^{-4}$ M LiCl and the detection limits for all electrodes were ca. $5{\times}10^{-4}$ M. The response time of the electrode was faster at the higher lithium concentration and the response of the electrode was stable for longer than 6 months. The sensor membranes exhibit improved response times and increased lifetimes as compared to the system described earlier.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Measuring economic sentiment using ordinary response options

  • Park, Inho;Kim, Tae Yoon
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.2
    • /
    • pp.163-172
    • /
    • 2017
  • Economic sentiment is typically measured using ordinary response options. The University of Michigan and the United States Conference Board are two widely used major indexes that have separately established independent consumer sentiment indexes based on three-level ordinary response options: positive, neutral, and negative. Notwithstanding, limited attention has been paid to the structural differences in their built-in formulas, which are referred to the disparate micro scoring schemes applied to an individual question. This paper examines the structural difference of the two indexes and then addresses situations where one is more reliable than the other. Real data from business tendency surveys of the Organization for Economic Cooperation and Development are used to illustrate our points empirically. As a conclusion, it is stressed that the two indexes should be handled with care when applied to economic sentiment comparison studies.

Analyzing Carbon-Neutral Campus Development Measures through Recognition Analysis of Students - Focused on Chungbuk National University - (학생 설문조사를 통한 탄소중립캠퍼스 조성요인 분석 - 충북대학교 재학생을 대상으로 -)

  • Woo, Hye-Mi;Baek, Jong-In;Kwak, Joo-Hyeon;Min, Suk-Gi;Choi, Choel-Gyu;Ban, Yong-Un
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.4
    • /
    • pp.1-9
    • /
    • 2010
  • In response to climate change under a university level, this study has intended to find carbon-neutral campus development measures for Chungbuk National University (CBNU), which is composed of such facilities as education, research, and residential buildings. To reach this goal, we reviewed related literatures to find development measures for carbon neutral campus, employed a survey method asking students to show their preference and suitability toward provided measures, and statistical analyses to find appropriate measures using factor analysis. We have found the following results. First, based on literature review, we have identified several concepts regarding carbon-neutral city and has found the elements of carbon-neutral campus development. Second, we have drawn carbon-neutral campus development measures of CBNU through factor analysis. Finally, based on the characteristics and the present carbon-neutral campus conditions of the CBNU, we presented development measures.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

The Impression Evaluation of the Cloth's Wearer in Relation to Tone Combination and Body Type of Wearer (의복의 톤조합과 착용자의 체형에 따른 인상평가 (제1보))

  • Paeng, Suk-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.6
    • /
    • pp.1007-1021
    • /
    • 2004
  • The purpose of this study is to find out the effect of wearers' body types and clothes' neutral tone combination on impression formation. The experimental materials developed for this study are a set of stimulus and response scales(7-point semantic). The stimulus include 45 pictures manipulated by computer simulation in wears' body types and neutral tone variation. The subjects are 540 female undergraduate students in Gyeong-nam. The results of this study are as follows: Impression factor of the stimulus consisted of 5 different dimensions including tenderness, cuteness, attractiveness, elegance, intrepidity. Each impression of neutral tone combinations, along with wears' body types, had a significant effect on tenderness, attractiveness, and intrepidity. Especially, it had the strongest effects on attractiveness. Each impression of wearers' body types along with neutral tone combinations affected cuteness significantly. According to the fact above, wears' body types and neutral tone combination have a significant influence on the impression formation of wearers.

  • PDF

The Effect of Wearer's Body Type and Clothing Type, Neutral Tone Combination on Impression Formation (착용자의 체형과 의복유형, 무채색 톤 조합이 인상형성에 미치는 영향)

  • Paeng Suk-Kyung;Kang Kyung-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1207-1218
    • /
    • 2005
  • The purpose of this study is to find out the effect of wearer's body type and clothing type, neutral tone combination on impression formation. The experimental materials developed for this study are a set of stimuli and response scales(The 7-point semantic). the stimuli are 90 pictures manipulated with wearer's body type, clothing type and neutral tone variation by computer simulation. The subjects are 540 female undergraduate students in Kyung-nam. The resulte of this study are as follows : Impression factor of the stimulus consisted of the 5 demensions(tenderness, cuteness, attractiveness, elegance, intrepidity). Wearer's body type had significant effects on all five factors. Especially, it had the strongest effects on attractiveness. Clothing type had significant effects on tenderness, attractiveness, intrepidity. Neutral tone combinations had significant effects on all factors except elegance. In regarding the effect of interaction between each variable, the combination of clothing type and neutral tone combination had significant effects on attractiveness, elegance, intrepidity.

The Impression Evaluation d the Dress's Wearer in Relation to Neutral Tone, Skirt Width and Length Variation (무채색의 톤과 스커트 폭.길이 변화에 따른 원피스드레스 착용자의 인상평가)

  • Chio, Su-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.2
    • /
    • pp.317-328
    • /
    • 2004
  • The purpose of this study was to identify the effect of three clothing cues(neutral tone, skirt width, and skirt length of dress) on the impressions of females. The experimental materials developed for this study were a set of stimuli and response scales. The stimuli were 20 color pictures manipulated with three clothing cues by drawing. The 7-point scale designed for visual evaluation of impression formation about females included 29 bipolar adjectives. The subjects were 240 undergraduate female students in Chinju city. The results of this study were as follows: By analyzing the impression of female figures by neutral tone, skirt width, and length, five factors including ability.activity, elegance, attractiveness, concentration of attention, and tenderness were identified. Among these factors, ability.activity and elegance were proved to be more important. Each impression of neutral tone with skirt width. length have significant effects on tenderness. Each impression of skirt width.length with neutral tone have significant effects on ability.activity.

  • PDF

In vitro Alternative Study of Phototoxitiy by Neutral Red Uptake Assay Using Human Fibroblast (사람유래의 섬유아세포 배양을 이용하여 NRU(neutral red uptake) 시험법에 의한 in vitro 광독성 대체시험연구)

  • 이종권;이은희;김형수;홍진태;류승렬;박기숙;김대병;김부영;조대현
    • Toxicological Research
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2000
  • This study was conducted to assess a possible alternative method as replacements for in vivo test. The human fibroblasts were exposed to several photoxic chemicals (promethazine, neutral red, chlortetracyclone, amiodatone, bithional, 8-methyooxypsorale) and non-phototoxi substance, ammonium laureth sulfate and irradiatied with 5 J/$cm^2$ of UVA (3320~420nm). The cell viability was measured by NRU (neutral red uptake) assay. The photoxic potential of test chemicals in the NRU PT (phototoxicity test) was assessed by determining the PIF (photoirritancy Factor) by using a cut-off value of 5. The NRU PT responses of most chemicals showed a close agreement with in vivo response except bithinol. There was a relatively good agreement between in vitro NRU assay and in vivo data. These results suggest that NRU assay using fibroblast could be used to predict the phototoxicity.

  • PDF

Assessment of Voigt and LRVE models for thermal shock analysis of thin FGM blade: A neutral surface approach

  • Ankit Kumar;Shashank Pandey
    • Structural Engineering and Mechanics
    • /
    • v.85 no.1
    • /
    • pp.105-118
    • /
    • 2023
  • The present work is an attempt to develop a simple and accurate finite element formulation for the assessment of thermal shock/thermally induced vibrations in pretwisted and tapered functionally graded material thin (FGM) blades obtained from Voigt and local representative volume elements (LRVE) homogenization models, based on neutral surface approach. The neutral surface of the FGM blade does not coincide with its mid-surface. A finite element model (FEM) is developed using first-order shear deformation theory (FSDT) and the FGM turbine blade is modelled according to the shallow shell theory. The top and the bottom layers of the FGM blade are made of pure ceramic and pure metal, respectively and temperature-dependent material properties are functionally graded in the thickness direction, the position of the neutral surface also depends on the temperature. The material properties are estimated according to two different homogenization models viz., Voigt or LRVE. The top layer of the FGM blade is subjected to high temperature and the bottom surface is either thermally insulated or kept at room temperature. The solution of the nonlinear profile of the temperature in the thickness direction is obtained from the Fourier law of heat conduction in the unsteady state. The results obtained from the present FEM are compared with the benchmark examples. Next, the effect of angle of twist, intensity of thermal shock, variable chord and span and volume fraction index on the transient response due to thermal shock obtained from the two homogenization models viz., Voigt and LRVE scheme is investigated. It is shown that there can be a significant difference in the transient response calculated by the two homogenization models for a particular set of material and geometric parameters.