• Title/Summary/Keyword: negative detector

Search Result 82, Processing Time 0.025 seconds

The Concentrations of PCBs in the Serum and Theri Predictors of Exposure n Korean Women (일부 한국 성인 여성들의 혈중 PCBs 농도 및 그 노출요인의 연구)

  • 민선영;정문호;이강숙;노영만;구정환
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.97-107
    • /
    • 2000
  • PCBs [Polychlorinated biphenyls] are halogenated aromatic compounds with the empirical formula C12H10-nCln(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors, transformers, plasticizers, lubricant inks, and paint additives. once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their high degree of lipophilicity. In 1970s, the worldwide production of PCBs seem to be still in use. The environmental load of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seem to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs I the serum samples of 112 women by GC/MSD(Hewlett Packard 5897 Gas Chromatography-Mass Chromatography Detector) and CG/ECD(Hewlett Packard 5890 series-II gas chromatography-Electron capture detector, U.S.A). The main results of this study were as follows; The mean and standard deviation of serum PCBs were 3.613, 0.759 ppb, respectively and median of it was 3.828 ppb. The correlation coefficients of the concentrations of 13 PCB congeners ranged from 0.7913 to 0..9985 and were significantly correlated between each items(p=0.0001). The PCB concentrations were positively associated with age(simple linear regression; R2=0.86, =0.08023, p<0.001) and with total lipids in serums(simple linear regression; R=0.7058, =0.00486, p<0.001). The age adjusted model (Y=$\beta$0+$\beta$1age+$\beta$2X) was applied for possible predictors of PCBs levels in serum. For BMI(Body Mass Index), major residential area, and fish, meat, and dairy consumption, there was no association with PCBs levels, Also there was negative association for the number of pregnancy and lactation period with PCBs levels.

  • PDF

Ovarian Masses: Is Multi-detector Computed Tomography a Reliable Imaging Modality?

  • Khattak, Yasir Jamil;Hafeez, Saima;Alam, Tariq;Beg, Madiha;Awais, Mohammad;Masroor, Imrana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2627-2630
    • /
    • 2013
  • Background: Ovarian cancer continues to pose a major challenge to physicians and radiologists. It is the third most common gynecologic malignancy and estimated to be fifth leading cancer cause of death in women, constituting 23% of all gynecological malignancies. Multi-detector computed tomography (MDCT) appears to offer an excellent modality in diagnosing ovarian cancer based on combination of its availability, meticulous technique, efficacy and familiarity of radiologists and physicians. The aim of this study was to compute sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of 64-slice MDCT in classifying ovarian masses; 95% confidence intervals were reported. Materials and Methods: We prospectively designed a cross-sectional analytical study to collect data from July 2010 to August 2011 from a tertiary care hospital in Karachi, Pakistan. A sample of 105 women aged between 15-80 years referred for 64-MDCT of abdomen and pelvis with clinical suspicion of malignant ovarian cancer, irrespective of stage of disease, were enrolled by non-probability purposive sampling. All patients who were already known cases of histologically proven ovarian carcinoma and having some contraindication to radiation or iodinated contrast media were excluded. Results: Our prospective study reports sensitivity, specificity; positive and negative predictive values with 95%CI and accuracy were computed. Kappa was calculated to report agreement among the two radiologists. For reader A, MDCT was found to have 92% (0.83, 0.97) sensitivity and 86.7% (0.68, 0.96) specificity, while PPV and NPV were 94.5% (0.86, 0.98) and 86.7% (0.63, 0.92), respectively. Accuracy reported by reader A was 90.5%. For reader B, sensitivity, specificity, PPV and NPV were 94.6% (0.86, 0.98) 90% (0.72, 0.97) 96% (0.88, 0.99) and 87.1% (0.69, 0.95) respectively. Accuracy computed by reader B was 93.3%. Excellent agreement was found between the two radiologists with a significant kappa value of 0.887. Conclusion: Based on our study results, we conclude MDCT is a reliable imaging modality in diagnosis of ovarian masses accurately with insignificant interobserver variability.

Electrical Detection of Ear Acupuncture Points and Musculoskeletal Pain (경혈탐측기에 반응한 이혈(耳穴)과 신체 동통 부위와의 관계 연구)

  • Kang, Mun-Su;Park, Hyun-Chul;Kim, Lak-Hyung;Yu, Jeong-Suk;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.24 no.6
    • /
    • pp.187-193
    • /
    • 2007
  • Objectives : The objectives of this study were to investigate the relationship between electrical detection of ear acupuncture points and musculoskeletal pain. Methods : 18 adults who have musculoskeletal pain without trauma factorsparticipated in this study. They answered the questionnaire and their ear acupuncture points were examined with electrical detectors. We analyzed the relationship between electrical detection of ear acupuncture points and musculoskeletal pain with concordance rate and validity. Results : Total concordance rates of the head region was 68.00%(questionnaire) 32.08%(investigation), that of vertebral region was 67.86%, 59.38%, that of both upper limbs was 86.67%, 39.69%, and that of both lower limbs was 50.00%, 23.46%. The true positive rate was 0.704, the true negative rate was 0.492, the false positive rate was 0.508, and the false negative rate was 0.296 in the validity test. In the head, two concordance rates of the temporal and occipital regions were relatively higher than those of the parietal and frontal regions. In the vertebral region, two concordance rates of the cervical and lumbar regions were relatively higher than those of the thoracic and sacrum regions. In the upper limb, two concordance rates of the shoulder and shoulder joints were relatively higher than those of the others. In the lower limb, concordance rates of investigation were relatively low at all areas. The right lower limb was relatively higher than the left in concordance rates of the questionnaire. Conclusions : The results suggest that electrical detection of ear acupuncture points can be used in the diagnosis and treatment of musculoskeletal pain.

  • PDF

X-RAY PHOTOELECTRON SPECTOSCOPIC ANALYSIS OF ALUMINUM COMPOUND ADSORBED ON PULP FIBER SURFACES

  • Takuya Kitaoka;Hiroo Tanaka
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04b
    • /
    • pp.239-244
    • /
    • 1999
  • aluminum sulfate (alum) as a representative retention aid in papermaking processes was added to pulp suspensions, and the aluminum components adsorbed on the pulp were investigated quantitatively by two types of X-ray elementary analyses with regard to simultaneous changes of their surface charges. X-ray photoelectron spectroscopy (XPS) and X-ray fluorescence analysis (XFA) were applied to determine the aluminum components retained in pulp pads up to ca. 10 nm and 100${\mu}$m depth, respectively. In other words, XPS was utilized to analyze the outermost surface layers of the samples, and XFA was available for measurement of their extensive regions. A particle charge detector (PCD) was used to monitor streaming potentials at various pHs of the pulp mixtures under moderate sharing conditions. At pH 4.5 of pulp suspensions containing alum, surface charges of pulp fibers varied from negative to slight negative (approximately neutral) according to adsorption of aluminum components onto the pulp fibers. Subsequently, when a dilute NaOH solution in limited amounts was added to pulp mixtures, both streaming potentials and surface aluminum content of the pulp fibers increased distinctly although little total aluminum retention increased. Further addition of alkali solutions brought drastic decreases of the surface charges and surface aluminum content, while total aluminum content, on the contrary, increased gradually under neutral conditions. These results indicate that residual aluminum ions remained in pulp suspensions are predominantly adsorbed on surfaces of pulp fibers by adequate alkali additions and they must sufficiently cationize the fiber surfaces with increases of somewhat cationic aluminum complexes formed on the surfaces. On the other hand, aluminum components formed in higher pH ranges have nearly no contribution to improvement of charge properties of the pulp fiber surfaces, even though aluminum retention in pulp pads increases. XPS and XFA analyses combined with streaming potential measurement using a PCD suggest close relationships between aluminum content on the pulp fiber surfaces and their charge properties.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

A Robust PLL of PCS for Fuel Cell System under Unbalanced Grid Voltages (불평형 계통전압에 강인한 연료전지용 전력변환시스템의 PLL 방법)

  • Kim, Yun-Hyun;Kim, Wang-Rae;Lim, Chang-Jin;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.103-105
    • /
    • 2008
  • In grid-interconnection system, a fast, robust and precise phase angle detector is most important to grid synchronization and the active power control. The phase angle can be easily estimated by synchronous dq PLL system. On the other hand under unbalanced voltage condition, synchronous dq PLL system has problem that harmonics occur to phase angle or magnitude of grid voltage because of the effect of the negative sequence components. So, To eliminate the negative sequence components, the PLL method using APF (All Pass Filter) in a stationery reference frame to extract positive sequence components under unbalanced voltage condition is researched. In this paper, we propose a new PLL method with decoupling network using APF in a synchronous reference frame to extract the positive sequence components of the grid voltage under unbalanced grid. The cut-off frequency of APF in a synchronous reference frame can be set to twice of the fundamental frequency comparing with that of APF in a stationery reference frame which is the fundamental frequency. The proposed PLL strategy can detect the phase angle quickly and accurately under unbalanced gird voltages. Simulation and experimental results are presented to verify the proposed strategy under different kind of voltage dips.

  • PDF

Comparison between Source-induced Dissociation and Collision-induced Dissociation of Ampicillin, Chloramphenicol, Ciprofloxacin, and Oxytetracycline via Mass Spectrometry

  • Lee, Seung Ha;Choi, Dal Woong
    • Toxicological Research
    • /
    • v.29 no.2
    • /
    • pp.107-114
    • /
    • 2013
  • Mass spectrometry (MS) is a very powerful instrument that can be used to analyze a wide range of materials such as proteins, peptides, DNA, drugs, and polymers. The process typically involves either chemical or electron (impact) ionization of the analyte. The resulting charged species or fragment is subsequently identified by the detector. Usually, single mass uses source-induced dissociation (SID), whereas mass/mass uses collision-induced dissociation (CID) to analyze the chemical fragmentations Each technique has its own advantages and disadvantages. While CID is most effective for the analysis of pure substances, multiple-step MS is a powerful technique to get structural data. Analysis of veterinary drugs ampicillin, chloramphenicol, ciprofloxacin, and oxytetracycline serves to highlight the slight differences between SID and CID. For example, minor differences were observed between ciprofloxacin and oxytetracycline via SID or CID. However, distinct fragmentation patterns were observed for ampicllin depending on the analysis method. Both SID and CID showed similar fragmentation spectra but different signal intensities for chloramphenicol. There are several factors that can influence the fragmentation spectra, such as the collision energy, major precursor ion, electrospray mode (positive or negative), and sample homogeneity. Therefore, one must select a fragmentation method on an empirical and case-by-case basis.

Development of a Cost-Effective Tele-Robot System Delivering Speaker's Affirmative and Negative Intentions (화자의 긍정·부정 의도를 전달하는 실용적 텔레프레즌스 로봇 시스템의 개발)

  • Jin, Yong-Kyu;You, Su-Jeong;Cho, Hye-Kyung
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.3
    • /
    • pp.171-177
    • /
    • 2015
  • A telerobot offers a more engaging and enjoyable interaction with people at a distance by communicating via audio, video, expressive gestures, body pose and proxemics. To provide its potential benefits at a reasonable cost, this paper presents a telepresence robot system for video communication which can deliver speaker's head motion through its display stanchion. Head gestures such as nodding and head-shaking can give crucial information during conversation. We also can assume a speaker's eye-gaze, which is known as one of the key non-verbal signals for interaction, from his/her head pose. In order to develop an efficient head tracking method, a 3D cylinder-like head model is employed and the Harris corner detector is combined with the Lucas-Kanade optical flow that is known to be suitable for extracting 3D motion information of the model. Especially, a skin color-based face detection algorithm is proposed to achieve robust performance upon variant directions while maintaining reasonable computational cost. The performance of the proposed head tracking algorithm is verified through the experiments using BU's standard data sets. A design of robot platform is also described as well as the design of supporting systems such as video transmission and robot control interfaces.

Design of Hybrid Network Probe Intrusion Detector using FCM

  • Kim, Chang-Su;Lee, Se-Yul
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2009
  • The advanced computer network and Internet technology enables connectivity of computers through an open network environment. Despite the growing numbers of security threats to networks, most intrusion detection identifies security attacks mainly by detecting misuse using a set of rules based on past hacking patterns. This pattern matching has a high rate of false positives and can not detect new hacking patterns, making it vulnerable to previously unidentified attack patterns and variations in attack and increasing false negatives. Intrusion detection and prevention technologies are thus required. We proposed a network based hybrid Probe Intrusion Detection model using Fuzzy cognitive maps (PIDuF) that detects intrusion by DoS (DDoS and PDoS) attack detection using packet analysis. A DoS attack typically appears as a probe and SYN flooding attack. SYN flooding using FCM model captures and analyzes packet information to detect SYN flooding attacks. Using the result of decision module analysis, which used FCM, the decision module measures the degree of danger of the DoS and trains the response module to deal with attacks. For the performance evaluation, the "IDS Evaluation Data Set" created by MIT was used. From the simulation we obtained the max-average true positive rate of 97.064% and the max-average false negative rate of 2.936%. The true positive error rate of the PIDuF is similar to that of Bernhard's true positive error rate.

A Study on Indoor Radon Concentrations in Urban Area (도시 일부지역에서의 실내 라돈농도에 관한 연구)

  • 김순애;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.