• Title/Summary/Keyword: neck width

Search Result 197, Processing Time 0.04 seconds

Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy (두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가)

  • Kwon, Dong Yeol;Kim, Jin Man;Chae, Moon Ki;Park, Tae Yang;Seo, Sung Gook;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.13-24
    • /
    • 2019
  • Purpose: CT scan range is insufficient for various reasons in head and neck Tomotherapy®. To solve that problem, Re-CT simulation is good because CT scan range affects accurate dose calculations, but there are problems such as increased exposure dose, inconvenience, and a change in treatment schedule. We would like to evaluate the minimum CT scan range required by changing the plan setup parameter of the existing CT scan range. Materials and methods: CT Simulator(Discovery CT590 RT, GE, USA) and In House Head & Neck Phantom are used, CT image was acquired by increasing the image range from 0.25cm to 3.0cm at the end of the target. The target and normal organs were registered in the Head & Neck Phantom and the treatment plan was designed using ACCURAY Precision®. Prescription doses are Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy. Target is designed to 95%~107% of prescription dose and normal organ dose is designed according to SMC Protocol. Under the same treatment plan conditions, Treatment plans were designed by using five methods(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm) and two pitches(0.43, 0.287). The accuracy of dose delivery for each treatment plan was analyzed by using EBT3 film and RIT(Complete Version 6.7, RIT, USA). Results: The accurate treatment plan that satisfying the prescribed dose of Target and the tolerance dose in normal organs(SMC Protocol) require scan range of at least 0.25cm for Fixed-1cm, 0.75cm for Fixed-2.5cm, 1cm for Dynamic-2.5cm, and 1.75cm for Fixed-5cm and Dynamic-5cm. As a result of AnalysisAnalysis by RIT. The accuracy of dose delivery was less than 3% error in the treatment plan that satisfied the SMC Protocol. Conclusion: In case of insufficient CT scan range in head and neck Tomotherapy®, It was possible to make an accurate treatment plan by adjusting the FW among the setup parameter. If the parameter recommended by this author is applied according to CT scan range and is decide whether to re-CT or not, the efficiency of the task and the exposure dose of the patient are reduced.

Morphological Characteristics of Sperm in the Korean Striped Field Mouse, Apodemus agrarius coreae: Possible Role of Sperm Neck in the Movement of Sperm Head

  • Lee, Jeong-Hun;Son, Seong-Won
    • Animal cells and systems
    • /
    • v.1 no.2
    • /
    • pp.371-379
    • /
    • 1997
  • To investigate the movement of sperm head and the role of sperm neck in forward sperm motility in the Korean striped field mouse, Apodemus agrarius coreae, the morphological characteristics of the cauda epididymal spermatozoa were examined by light microscopy and scanning and transmission electron microscopy. Spermatozoa of A. agrarius coreae were characterized by the conspicuous shape of the acrosome and the long tail compared with those of other rodents. Total length of the sperm was $133\mu{m}$. The sperm head had a curved falciform shape. The head was 8.0${\mu}$m in length, and about 4.0 ${\mu}$m in width. The shape of acrosome had an openerlike form. The sperm tail (125 ${\mu}$m) consisted of four major segments: neck (0.5 ${\mu}$m), middle piece (29.5 ${\mu}$m), and principal piece plus the end piece (95 ${\mu}$m). The outer dense fibers were arranged in a horseshoe fashion, and No. 1, 5, 6, and 9 of the outer dense fibers were larger than the others. The mitochondrial bundles of middle piece were composed of a pair of arms, which surrounded the axone of the middle piece by the 45 0 angled helical structure. The total number of mitochondrial gyres was 188. In particular, the microfilament structures existed in plasma membrane of the sperm, which was adjacent to the acrosomal region on the nuclear membrane. The segmented columns were surrounded by microfilament structures, and the microfilament bundles were adjacent to the outer membrane of the first mitochondria of middle piece. This study presents for the first time the existence of microfilament structures within the plasma membrane of sperm which is located from the adjacent acrosome region to the connecting piece in sperm neck of Korean striped field mouse, Apodemus agrarius coreae. The present result suggests that the constriction and extension of microfilament in sperm neck as well as the wave-movement of sperm tail may play a role in the movement of sperm head.

  • PDF

RADIATIVE HEAT TRANSFER ANALYSIS OF GLASS FIBER DRAWING IN OPTICAL FIBER MANUFACTURING (광섬유 생산용 유리섬유 인출공정에 대한 복사 열전달 해석)

  • Kim, K.;Kim, D.;Kwak, H.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • In this study, the glass fiber drawing from a silica preform in the furnace for the optical fiber manufacturing process is numerically simulated by considering the radiative heating of cylindrically shaped preform. The one-dimensional governing equations of the mass, momentum, and energy conservation for the heated and softened preform are solved as a set of the boundary value problems along with the radiative transfer approximation between the muffle tube and the deformed preform shape, while the furnace heating is modeled by prescribing the temperature distribution of muffle tube. The temperature-dependent viscosity of silica plays an important role in formation of preform neck-down profile when the glass fiber is drawn at high speed. The calculated neck-down profile of preform and the draw tension are found to be reasonable and comparable to the actual results observed in the optical fiber industry. This paper also presents the effects of key operating parameters such as the muffle tube temperature distribution and the fiber drawing speed on the preform neck-down profile and the draw tension. Draw tension varies drastically even with the small change of furnace heating conditions such as maximum heating temperature and heating width, and the fine adjustment of furnace heating is required in order to maintain the appropriate draw tension of 100~200 g.

A comparison of women's pattern between the Bunka and the Secoli (신문화식과 세꼴리식 여성복 원형 비교)

  • 최영림;김희은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.11
    • /
    • pp.1190-1197
    • /
    • 2003
  • The purpose of this study is to compare and analyze methods of women's apparel prototypes and provide for some useful fundamental data to improve the apparel prototype suitable for Korean women. Two different drafting methods, the Bunka pattern of Japan Bunka Women's University and the Secoli pattern of Italy istituto carlo secoli, an italian pattern drafting institute, were selected. The result and discussion are as follows; In the calculation formula, the Bunka was shown more comfort at arm-hole part, because of it's lower arm-hole depth, wider arm-hole width and lower cap height in comparison with the Secoli. At the shoulder angle, the Bunka is inclined more in front shoulder than the back shoulder, whereas the Secoli is inclined more in back shoulder than the front shoulder. It could explain that the Bunka is suitable for bendforward type and the Secoli is suitable for lean-back type. In the sensory test, the one-piece pattern of the Secoli with 4cm ease was highly estimated in ease. It seems young women's preference to body conscious clothes which reflected in many new elastic fabrics. At the bust point to neck, the Bunka was highly estimated, compared with the Secoli. It seems like to be caused that for the bust point to neck formula, the Bunka used bust girth, the Secoli used stature which has low correlation with the bust point to neck.

A Study on Body Types of Mongolian Women (몽골 성인여성체형에 관한 연구)

  • 홍정민
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.6
    • /
    • pp.167-176
    • /
    • 2001
  • This study analyzes characterization and classification of body types of Mongolian women aged 18∼39 ages. The anthropometric measurements of the research subjects come up to a total of 23 items and are summarized as follows : 1. As the results of comparative analysis of the body measurements by age group, 16 items show a significant difference except shoulder height, thigh girth, neck base girth, back length shoulder length, sleeve length and weight. Both age group are considered to be of average weight but 25 to 39 age group were slightly greater than that of the 18 to 24 age group. 2. As the results of factor analysis, 4 factors such as the first factor on the obesity of body, the second factor on the vertical size of body, the third factor on the back length, the forth factor on the shoulder width and neck base girth were extracted. 3. As the results of classification based on the duster analysis, the body types were classified into 3 types in each age group. In each age group the most frequent body type is average stature and slightly thin type.

  • PDF

Giant basal cell carcinoma of the left lateral neck

  • Baik, Bongsoo;Park, Sulki;Ji, Soyoung;Kim, Sunyoung
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.3
    • /
    • pp.173-176
    • /
    • 2021
  • Basal cell carcinoma is a malignant epithelial neoplasm of the skin and the most common human skin cancer. It is generally associated with a good prognosis. In this case report, a giant basal cell carcinoma of the nodulo-ulcerative type showing wide ulceration with marginal multiple small nodules, is presented. It was trapezoidal in shape, having dimensions of 7 cm at the greatest basal width, 6 cm vertically with different anterior and posterior margin dimensions, and 5 cm horizontally at the top margin. After wide excision of the lesion including 5-10 mm safety margins, the wound was reconstructed with a local skin flap and split-thickness skin graft. The reconstructed wound healed well without recurrence for 1 year.

An Analysis on Retro Jacket Designs of Haute Couture Designers for the Development of High-Value Added Fashion Products (고부가가치 패션제품개발을 위한 오뜨꾸뛰르 디자이너 복고적 재킷디자인 분석)

  • Kim, Eonjeong;Yoo, Youngsun
    • Journal of the Korean Society of Costume
    • /
    • v.64 no.3
    • /
    • pp.77-92
    • /
    • 2014
  • The purpose of this research is to examine the expression methods of Haute Couture designers' high value-added jacket designs, In order to achieve this, the positions and sizes of the design component items of tailored jackets designed by Haute Couture designers from the 1940s to the 1970s were analyzed. The results of the analysis are as follows. First, the silhouette changed while leading the contemporaneous fashions, and such changes could be confirmed by the width and length of the jacket's shoulder, chest, waist, and hem that determine the silhouette. Particularly, the length of the chest changed which signifies that the depth of the armhole was playing an important role in the production of high value-added jackets in relation to the sleeves and the fit of jackets. Second, the position and the size of the dart are the components that can express the fit of a jacket and the designer's creativity, The starting point position of the dart and the position passing by waist, and the position of the end of the dart were placed in the position beyond B.P. depending on the designer's creativity and techniques, deriving the changes of the silhouette and creating high value-added jackets. Third, the tailored collar, which was a three-dimensional component made up of the upper collar, gorge line, lapel, and break line, was an important component that could express high value-added jackets. Changes in the width and the height of the break line position of the sides of the neck were represented as changes in the neck size of the collar, and changes in the vertex locations of the upper collar corner-point, the gorge line (the corner-point of the lapel and V zone) were also represented as diverse tailored collar designs. And the differences in the width and the length of each component of the collar were related to each other and represented as changes in the slope and angle of the collar outline. Fourth, the changes in sleeve designs of the jacket were in such items as the width of the sleeve opening, the width of the sleeve hem, and the length of the sleeve, and were represented as diverse sleeve designs such as widened sleeve opening types, and straight line types.

Factor Analysis of Biometric Traits of Kankrej Cows to Explain Body Conformation

  • Pundir, R.K.;Singh, P.K.;Singh, K.P.;Dangi, P.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.4
    • /
    • pp.449-456
    • /
    • 2011
  • Eighteen different biometric traits in 407 Kankrej cows from their breeding zone, i.e. Palanpur district of Gujarat, India, were recorded and analyzed by factor analysis to explain body conformation. The averages of body length, height at withers, height at shoulder, height at knee, heart girth, paunch girth, face length, face width, horn length, horn diameter, distance between horns, ear length, ear width, neck length, neck diameter, tail length with switch, tail length without switch and distance between hip bones were $123.44{\pm}0.37$, $124.49{\pm}0.28$, $94.68{\pm}0.30$, $38.2{\pm}0.14$, $162.56{\pm}0.56$, $178.95{\pm}0.70$, $44.09{\pm}0.10$, $15.91{\pm}0.05$, $42.47{\pm}0.53$, $26.07{\pm}0.19$, $13.34{\pm}0.08$, $31.24{\pm}0.12$, $16.10{\pm}0.05$, $50.63{\pm}0.18$, $73.21{\pm}0.32$, $111.62{\pm}0.53$, $89.34{\pm}0.34$ and $17.28{\pm}0.10\;cm$, respectively. The correlation coefficients between different traits ranged from -0.806 (horn diameter and distance between horns) to 0.815 (heart girth and paunch girth). Most of the correlations were positive and significant. Factor analysis with promax rotation with power 3 revealed three factors which explained about 66.02% of the total variation. Factor 1 described the cow body and explained 38.89% of total variation. The second factor described the front view/face of the cow and explained 19.68% of total variation. The third factor described the back of the cow and explained 7.44% of total variation. It was necessary to include some more variables for factor 3 to obtain a reliable estimate of the back view of the cow. The lower communities shown for distance between horns, horn diameter, ear width and neck diameter indicated that these traits did not contribute effectively to explaining body conformation and can be dropped from recording, whereas all other traits are important and needed to explain body conformation in Kankrej cows. The result suggests that principal component analysis (PCA) could be used in breeding programs with a drastic reduction in the number of biometric traits to be recorded to explain body conformation.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

A Study on the Distribution Methods of Tensile Property for Women′s Knit Block (여성용 Knit Block의 신장률 배분 방식에 관한 연구)

  • 허은영;조진숙
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.8
    • /
    • pp.203-218
    • /
    • 2004
  • Recently, knitted materials are used more often than ever before in fashion. Therefore it is necessary to study their application into garment patterns. The purpose of this study was to develop a system by which the tensile property of knitted fabrics can be applied. In this study, 5 different distribution methods of tensile property were tested on 2 sample fabrics which have a lower and higher tensile property than moderate-stretch. The subjects were five women within an age range from 18 to 24 who showed average body figures. The major findings derived from this investigation were as follows; The 4th method was regarded as the most valid. The 4th method was fixed proportional alteration based on the reduction amount of bust girth, i.e. front (back) width and shoulder width reduced by 60% of the bust girth reduction and neck point reduced by 28% of the bust girth reduction. When the reduction was based on the proportion of the actual measurements, the alteration was too severe, so that the armhole curve was changed into a very uncomfortable curve.