• Title/Summary/Keyword: natural vibration

Search Result 3,245, Processing Time 0.03 seconds

Dynamic Test and Analysis of Multilevel Post-tensioned PSC Girder with Holed Web (중공부가 있는 다단계 긴장 PSC 거더의 동특성 실험 및 해석)

  • Park, Bong-Sik;Cho, Jae-Yeol;Han, Man-Yeob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.11-12
    • /
    • 2010
  • PSC girder with holed web have several benefits. Most of all placing tendon anchorage in the holes can make prestressing forces be loaded stepwise. In addition it can reduce the self-weight of the beams and increase the span length of beams. And holed web might minimize the interference of view. In this study, a 50-meter long full scale multilevel post-tensioned PSC girder was fabricated and modal test was carried out. In order to obtain precise frequency response, vibration exciter was placed at the middle of the girder and excited with several frequencies. Natural frequency and damping ratio were evaluated from FFT and PSD using the obtained frequency response and compared with numerical analysis result.

  • PDF

A Study on The Identification of Characteristics For The 2 Dimensional Continuous Vibration System By Mass Sensitivity Analysis (질량감도 해석에 의한 2차원 연속계의 진동특성에 관한 연구)

  • Lee, Jung-Yoon;Park, Ho;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.339-348
    • /
    • 1990
  • Techniques which are able to predict and control dynamic characteristics, not affecting the vibrational characteristics on the modification of structural design, are being studied. As one of these techniques, experimental modal analysis is widely applied by many researchers. In this study, modal analysis is performed using transfer matrix method by a macro computer. The developed program would estimate the structural modal parameters precisely, and the validity of this program is certified by comparing with the experimental results of .GAMMA A. structure. Estimated modal parameters(natural frequency, vibrational mode, equivalent mass, etc.) are in accord with the experimental results. Also, the optimal location of the additive mass is determined by the evaluation of the vibrational mode and the equivalent mass. The relation between the additive mass and the equivalent mass is specified, and we come to know that the ratio of equivalent mass to additive mass alter linearly within the range of 20%.

Numerical Study on Effects of Velocity Profile of Liquid Container on Sloshing (액체 용기의 속도 프로파일이 슬로싱에 미치는 영향 해석)

  • Kim, Dongjoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.313-319
    • /
    • 2016
  • It is very important to understand and control the sloshing in a liquid container that is partially filled with liquid. Previous studies focused primarily on the sloshing and resonance caused by sinusoidal excitations, while the present study focuses on understanding and suppressing sloshing in a container that moves rapidly from a given point to another in industrial applications. To achieve this, we first numerically predict the two-phase flow induced by the horizontal movement of a rectangular container. Then we analyze the effects of container-velocity profile (in particular acceleration/deceleration duration) on sloshing. Results show that sloshing is significantly suppressed when the acceleration/deceleration duration is a multiple of the 1st-mode natural period of sloshing.

A Study of Vibration Analysis Due to Structual Changes of Dynamic Structure (동적 구조물의 구조변화에 의한 진동해석 연구)

  • 현천성;이기형;정인성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2033-2048
    • /
    • 1992
  • This paper presents the theoretical development and qualitative evaluation of a new concept in the mathematical modeling of dynamic structures. We use both test data and analytical approximations to identify the parameters of an incomplete model. The model has the capability of predicting the response of the points of interest on the structure over the frequency range of interest and can be used to predict the changes in natural frequencies and normal modes due to structural changes. The theory was tested by running simulated tests on a relatively simple structure, identifying the parameters of the incomplete model, and using this model to predict the effects on frequency and mode shapes of several mass and stiffness changes. The conditions of the tests were varied by selecting different numbers of points of measurement, varying the frequency range, and by including assumed measurement error. It is recommended that the theoretical development be continued and that applications to more complex structures be carried out in order to develop a better understanding of the limitations and capabilities of the method. A successful, more definitive sevaluation could lead to immediate practical applications.

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

Rapid seismic performance assessment method for one story hinged precast buildings

  • Palanci, Mehmet;Senel, Sevket Murat
    • Structural Engineering and Mechanics
    • /
    • v.48 no.2
    • /
    • pp.257-274
    • /
    • 2013
  • In this study, seismic performance of one story hinged precast buildings, which represents the majority of existing lightweight industrial building stock of Turkey, was assessed. A lot of precast buildings, constructed in one of the important seismic zones of western Turkey, were investigated and building inventories were prepared. By this method, structural properties of inventory buildings and damaged precast buildings in recent earthquakes were compared. Damage estimations based on nonlinear analysis methods have shown that estimated damage levels of inventory buildings and observed damage levels in recent earthquakes are similar. Accuracy of damage estimation study and the simplicity of the one story precast building models implied that rapid seismic performance assessment method for these buildings can be developed. In this assessment method, capacity curves and vibration periods of precast buildings were calculated by using structural properties of precast buildings. The proposed assessment method was applied to inventory buildings by using two different seismic demand scenarios which reflect moderate and soft soil conditions. Comparison of detailed analysis and rapid assessment methods have indicated that reliable seismic performance estimations can be performed by using proposed method. It is also observed that distribution of damage estimations is compatible in both scenarios.

Estimation of Group Walking Loads by System Identification of Building Structures (건축구조물의 시스템 식별을 통한 무리보행하중 평가)

  • 김태호;민경원;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

Life Analysis and Reliability Prediction of Micro-Switches based on Life Prediction Method

  • Ji, Jung-Geon;Shin, Kun-Young;Lee, Duk-Gyu;Song, Moon-Shuk;Lee, Hi-Sung
    • International Journal of Railway
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Reliability means that a product maintains its initial quality and performance at a certain period of time (time, distance, cycle etc) under given condition without failure. The given conditions include both environmental condition and operating condition. Environmental condition means a common natural environment such as temperature, humidity, vibration, and working condition means an artificial environment such as voltage, current load, place for installment, and hours of use, which occurs during the life of the product. In the field of railway vehicles, it is mandatory to use a part with the proved reliability as the extension of the life of vehicle become highly necessary. But the reliable assessment method for the reliability of the part is insufficient. If the reliability of the railway vehicle parts could be assessed by using the field data, the reliability of the entire system could also be evaluated reliably. In this study, life span of micro-switch for master controller is analyzed and prediction is performed based on its field data given by an operator considering the special circumstances of railway vehicles such as the operation of a large number of trains on the same line.

Study on Discharge Electrode Design applied for Road Tunnel (터널용 전기집진시스템 개발을 위한 방전극 설계)

  • Kim, Jong-Ryul;Weon, Jong-Oung;Jang, Chun-Man
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1238-1243
    • /
    • 2009
  • As Social Overhead Capital(SOC) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, it is needed to introduce a compulsory ventilation system as well as natural ventilation mechanism. The former, that is, a special compulsory ventilation facility is very useful and helpful to prevent a tunnel of being contaminated by traffic in most case. In the case of obtaining clearer and longer driving view, the ventilation systems have to be considered in order to remove floating contaminants or exhaust gas from engines. In this paper, discharge electrode design technology will be discussed.

  • PDF

Dynamic Response Analysis of Top-tensioned Riser Under Sheared Current Load (전단류 하중을 받는 상부장력 라이저의 동적 응답 해석)

  • Kim, Kookhyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.83-89
    • /
    • 2013
  • A numerical scheme based on a mode superposition method is presented for the dynamic response analysis of a top-tensioned riser (TTR) under sheared current loads. The natural frequencies and mode shapes of the TTR have been calculated analytically for a beam with a slowly varying tension and pinned-pinned boundary conditions at the top and bottom ends. The lift coefficients and corresponding amplitudes used to estimate the vortex-induced modal force and damping for each mode were predicted via iterative calculations based on the input and output power balancing concept. Here, the power-in regions were controlled by the normal distribution function, for which the center was coincident with the lock -in location by local vortex-shedding, and the range was defined by the constant standard deviation for the reduced velocity by the local current speed. Finally, dynamic responses such as root-mean-squared displacement and stress were calculated using the mode superposition technique. In order to verify the presented scheme, a numerical calculation was performed for a TTR under an arbitrary linearly sheared current and linearly varying tension. A comparison with the results of the existing software showed that the presented scheme could give reliable and feasible solutions. Case studies were performed to investigate the effects of various current loads and tensions.